Parameter Symbol Test Condition Min Typ Max Unit
Note:
1. See the 5. Ordering Guide to determine Bop/Brp for various OPNs.
2. See the 5. Ordering Guide for operating a release points. These are defined as maximum operating point and minimum release
point -40 °C to +150 °C and do not include the effect of noise.
3. For a single conversion. This can be reduced by the square root of N by filtering over N samples. See ordering guide for samples
taken per measurement.
Table 1.6. Temperature Compensation
Parameter Symbol Test Condition Min Typ Max Unit
Bop and Brp vs Temperature No compensation
0-70°C
< ±0.05 %/°C
Neodymium compensation -0.12 %/°C
Ceramic compensation -0.2 %/°C
Table 1.7. Thermal Characteristics
Parameter Symbol Test Condition Value Unit
Junction to Air Thermal Resistance θ
JA
JEDEC 4 layer board no airflow SOT23-5 212.8 °C/W
Junction to Board Thermal Resistance θ
JB
JEDEC 4 layer board no airflow SOT23-5 45 °C/W
Junction to Air Thermal Resistance θ
JA
JEDEC 4 layer board no airflow SOT23-3 254.6 °C/W
Junction to Board Thermal Resistance θ
JB
JEDEC 4 layer board no airflow SOT23-3 54.8 °C/W
Si720x Switch/Latch Hall Effect Magnetic Position Sensor Data Sheet
Electrical Specifications
silabs.com | Building a more connected world. Rev. 0.92 | 6