Data Sheet HMC557A
Rev. C | Page 3 of 23
ELECTRICAL SPECIFICATIONS
2.5 GHz TO 5.0 GHz FREQUENCY RANGE
T
A
= 25°C, IF = 100 MHz, LO drive = 15 dBm. All measurements performed as a downconverter with the upper sideband selected, unless
otherwise noted.
Table 1.
Parameter Min Typ Max Unit
OPERATING CONDITIONS
RF Frequency Range 2.5 5.0 GHz
IF Frequency Range DC 3 GHz
PERFORMANCE
Noise Figure, Single Sideband (SSB) 8 dB
LO to RF Isolation 40 50 dB
LO to IF Isolation 26 35 dB
RF to IF Isolation 20 dB
Input Third-Order Intercept (IP3) 14 18 dBm
Input Second-Order Intercept (IP2) 55 dBm
Input Power for 1 dB Compression (P1dB) 10 dBm
RF Port Return Loss 10 dB
LO Port Return Loss 8 dB
5.0 GHz TO 7.0 GHz FREQUENCY RANGE
T
A
= 25°C, IF = 100 MHz, LO drive = 15 dBm. All measurements performed as a downconverter with the upper sideband selected, unless
otherwise noted.
Table 2.
OPERATING CONDITIONS
LO Frequency Range 5.0 7.0 GHz
IF Frequency Range DC 3 GHz
Conversion Loss 8.5 10.5 dB
Noise Figure, Single Sideband (SSB) 8.5 dB
LO to RF Isolation 37 43 dB
LO to IF Isolation 25 33 dB
RF to IF Isolation 25 dB
Input Third-Order Intercept (IP3) 14 18 dBm
Input Second-Order Intercept (IP2) 55 dBm
Input Power for 1 dB Compression (P1dB) 10 dBm
RF Port Return Loss 12 dB
LO Port Return Loss 12 dB