WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
℃
CONSTANT CURRENT REGION
Note.4
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.6
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY
(Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
STANDBY POWER CONSUMPTION
SAFETY STANDARDS Note.7
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
OVER CURRENT
Note.4
OVER VOLTAGE
OVER TEMPERATURE
Adjustable for A-Type only (via built-in potentiometer)
Adjustable for A-Type only (via built-in potentiometer)
500ms, 80ms/ 115VAC, 230VAC
15ms / 115VAC, 230VAC
90 ~ 305VAC 127 ~ 431VDC
(Please refer to "STATIC CHARACTERISTIC" section)
47 ~ 63Hz
7A / 115VAC 3.3A / 230VAC 2.9A / 277VAC
<0.75mA / 277VAC
<0.5W at remote off
95 ~ 108%
Constant current limiting, recovers automatically after fault condition is removed
Compliance to Class B ,, EN55015, EN61000-3-2 Class C ( ) ; EN61000-3-3EN55032 (CISPR32) @ load 50% EAC TP TC 020≧
Compliance to ( ),
EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level
surge immunity Line-Earth 4KV, Line-Line 2KV EAC TP TC 020
20 ~ 95% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH non-condensing
℃
±℃ ℃
0.03%/ (0 ~ 55 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL60950-1, UL8750(type”HL”), CSA C22.2 No. 250.13-12, ENEC EN61347-1, EN61347-2-13 independent, EN62384, IP65 or IP67,
J61347-1, J61347-2-13, CCC GB4943.1, EAC TP TC 004 approved, AS/NZS 60950.1(by CB)
76.9K hrs min. MIL-HDBK-217F (25 )℃
280*144*48.5mm (L*W*H)
Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, re-power on to recover
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
SAFETY &
EMC
(Note 10)
PROTECTION
SHORT CIRCUIT
Constant current limiting, recovers automatically after fault condition is removed
13 ~ 16V 16.5 ~ 20.5V
22 ~ 26V
26 ~ 30V
32.5 ~ 36.5V
39.5 ~ 43.5V 52.5 ~ 56.5V
46 ~ 50V 59 ~ 63V
92%
92.5%
93.5%
93.5%
94.5%
94.5%
95%
95%
95%
95%
95.5%
95.5%
96%
96%
96%
96%
96%
96%
±3.0%
20 ~ 40A
±2.0%
18 ~ 36A
±1.5%
14 ~ 28A
±1.0%
12.5 ~ 25A
±1.0%
10 ~ 20A
±1.0%
8.3 ~ 16.7A
±1.0%
6.2 ~ 12.5A
±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±0.5%
±0.5%
±2.0%
±1.5% ±1.0% ±0.5% ±0.5%
±0.5%
±0.5%
±1.0%
5.6 ~ 11.2A
±0.5%
±0.5%
±1.0%
7.1 ~ 14.3A
±0.5%
±0.5%
12V
6 ~12V
15V
7.5 ~ 15V
20V
10 ~ 20V
24V
12 ~ 24V
30V
15 ~ 30V
36V
18 ~ 36V
48V
24 ~ 48V
40A 36A 28A 25A
20A
16.7A
12.5A
480W 540W 560W 600W 600W
601.2W
600W
150mVp-p 150mVp-p
12.7 ~ 15.8V
150mVp-p
17 ~ 21V
150mVp-p
20.4 ~ 25.2V
200mVp-p
25.5 ~ 31.5V
250mVp-p
30.6 ~ 37.8V
250mVp-p
40.8 ~ 50.4V10.2 ~ 12.6V
54V
27 ~ 54V
11.2A
604.8W
350mVp-p
45.9 ~ 56.7V
42V
21 ~ 42V
14.3A
600.6W
250mVp-p
35.7 ~ 44.1V
EMC IMMUNITY
EMC EMISSION
Note.7
COLD START 70A(t =1000 s measured at 50% I ) at 230VAC;width peak Per NEMA 410
μ
230VAC
277VAC
FUNCTION
REMOTE ON/OFF CONTROL
Power on : "High" >2 ~ 5V or Open circuit Power off : "Low" <0 ~ 0.5V or Short circuit
600W Constant Voltage + Constant Current LED Driver
HLG-600H series
File Name:HLG-600H-SPEC 2018-08-03
5V STANDBY
5V : 5V@0.5A ; tolerance 5%, ripple : 100mVp-p(max.)
SB
±
HLG-600H-12
HLG-600H-15
HLG-600H-20
HLG-600H-24
HLG-600H-30
HLG-600H-36
HLG-600H-48
HLG-600H-54
HLG-600H-42
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
1 unit (circuit breaker of type B) / 2 units (circuit breaker of type C) at 230VAC
TOTAL HARMONIC DISTORTION
THD< 20% (@ load 50% /115VAC, 230VAC; @ load 75%/277VAC)≧≧
(Please refer to “TOTAL HARMONIC DISTORTION (THD)” section)
PACKING
3.9Kg; 4pcs/16.6Kg/0.9CUFT
NOTE
PF 0.98/115VAC, PF 0.95/230VAC, PF 0.93/277VAC @ full load≧≧≧
(Please refer to " " )POWER FACTOR (PF) CHARACTERISTIC section
1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to "DRIVING METHODS OF LED MODULE".
5. De rating may be needed under low input voltages. Please .- refer to STATIC CHARACTERISTIC sections for details
6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
7. The model certified for CCC(GB19510.14, GB19510.1, GB17743 and GB17625.1) is an optional model . Please contact MEAN WELL for details.
8. This series meets the typical life expectancy of >62,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75 or less. ℃
9. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
10. d The is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
river a
mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. 360 360 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
11. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
Tcase= -40 ~ +90℃ (Please refer to "OUTPUT LOAD vs TEMPERATURE" section)
Tcase= +90℃
MAX. CASE TEMP.