Exar Corporation 48720 Kato Road, Fremont CA, 94538 • 510-668-7017 • www.exar.com SP3220E_EB_EU_102_102016
13
Figure 16. Charge Pump — Phase 2
V
CC
= +5V
V
SS
Storage Capacitor
V
DD
Storage Capacito
r
C
1
C
2
C
3
C
4
+
+
++
-5.5V
V
CC
= +5V
–5V –5V
+5V
V
SS
Storage Capacitor
V
DD
Storage Capacitor
C
1
C
2
C
3
C
4
+
+
++
Figure 15. Charge Pump — Phase 1
Figure 18. Charge Pump — Phase 3
V
CC
= +5V
–5V –5V
+5V
V
SS
Storage Capacitor
V
DD
Storage Capacitor
C
1
C
2
C
3
C
4
+
+
++
Figure 19. Charge Pump — Phase 4
V
CC
= +5V
V
SS
Storage Capacitor
V
DD
Storage Capacito
r
C
1
C
2
C
3
C
4
+
+
++
+5.5V
Figure 17. Charge Pump Waveforms
Ch1 2.00V Ch2 2.00V M 1.00µs Ch1 5.48V
2
1
T
T[]
T
+6V
a) C
2+
b) C
2
-
GND
GND
-6V
DESCRIPTION
14
Exar Corporation 48720 Kato Road, Fremont CA, 94538 • 510-668-7017 • www.exar.com SP3220E_EB_EU_102_102016
ESD TOLERANCE
The SP3220E/EB/EU device incorpo-
rates ruggedized ESD cells on all driver
output and receiver input pins. The ESD
structure is improved over our previous
family for more rugged applications and
environments sensitive to electro-static
discharges and associated transients. The
improved ESD tolerance is at least +15kV
without damage nor latch-up.
There are dierent methods of ESD testing
applied:
a) MIL-STD-883, Method 3015.7
b) IEC61000-4-2 Air-Discharge
c) IEC61000-4-2 Direct Contact
The Human Body Model has been the
generally accepted ESD testing method
for semi-conductors. This method is also
specied in MIL-STD-883, Method 3015.7
for ESD testing. The premise of this ESD test
is to simulate the human body’s potential to
store electro-static energy and discharge it
to an integrated circuit. The simulation is
performed by using a test model as shown
in Figure 20. This method will test the IC’s
capability to withstand an ESD transient
during normal handling such as in manu-
facturing areas where the IC's tend to be
handled frequently.
The IEC-61000-4-2, formerly IEC801-2, is
generally used for testing ESD on equipment
and systems. For system manufacturers,
they must guarantee a certain amount of ESD
protection since the system itself is exposed
to the outside environment and human pres-
ence. The premise with IEC61000-4-2 is that
the system is required to withstand an amount
of static electricity when ESD is applied to
points and surfaces of the equipment that
are accessible to personnel during normal
usage. The transceiver IC receives most
of the ESD current when the ESD source is
applied to the connector pins. The test circuit
for IEC61000-4-2 is shown on Figure 21.
There are two methods within IEC61000-4-2,
the Air Discharge method and the Contact
Discharge method.
With the Air Discharge Method, an ESD
voltage is applied to the equipment under
test (EUT) through air. This simulates an
electrically charged person ready to connect
a cable onto the rear of the system only to
nd an unpleasant zap just before the person
touches the back panel. The high energy
potential on the person discharges through
an arcing path to the rear panel of the system
before he or she even touches the system.
This energy, whether discharged directly or
through air, is predominantly a function of the
discharge current rather than the discharge
voltage. Variables with an air discharge such
as approach speed of the object carrying the
ESD potential to the system and humidity
will tend to change the discharge current.
For example, the rise time of the discharge
current varies with the approach speed.
The Contact Discharge Method applies the
ESD current directly to the EUT. This method
was devised to reduce the unpredictability
of the ESD arc. The discharge current rise
time is constant since the energy is directly
transferred without the air-gap arc. In situ-
ations such as hand held systems, the ESD
charge can be directly discharged to the
Figure 20. ESD Test Circuit for Human Body Model
R
C
Device
Under
Test
DC Power
Source
C
S
R
S
SW1
SW2
DESCRIPTION
Exar Corporation 48720 Kato Road, Fremont CA, 94538 • 510-668-7017 • www.exar.com SP3220E_EB_EU_102_102016
15
DEVICE PIN HUMAN BODY IEC61000-4-2
TESTED MODEL Air Discharge Direct Contact Level
Driver Outputs +15kV +15kV +8kV 4
Receiver Inputs +15kV +15kV +8kV 4
equipment from a person already holding
the equipment. The current is transferred
on to the keypad or the serial port of the
equipment directly and then travels through
the PCB and nally to the IC.
The circuit models in Figures 20 and 21 rep-
resent the typical ESD testing circuit used for
all three methods. The C
S
is initially charged
with the DC power supply when the rst
switch (SW1) is on. Now that the capacitor
is charged, the second switch (SW2) is on
while SW1 switches o. The voltage stored
in the capacitor is then applied through R
S
,
the current limiting resistor, onto the device
under test (DUT). In ESD tests, the SW2
switch is pulsed so that the device under
test receives a duration of voltage.
For the Human Body Model, the current
limiting resistor (R
S
) and the source capacitor
(C
S
) are 1.5kΩ an 100pF, respectively. For
IEC-61000-4-2, the current limiting resistor
(R
S
) and the source capacitor (C
S
) are 330Ω
an 150pF, respectively.
Figure 22. ESD Test Waveform for IEC61000-4-2
Figure 21. ESD Test Circuit for IEC61000-4-2
Table 3. Transceiver ESD Tolerance Levels
R
S
and
R
V
add up to 330Ω for IEC61000-4-2.
R
C
Device
Under
Test
DC Power
Source
C
S
R
S
SW1
SW2
R
V
Contact-Discharge Model
t = 0ns t = 30ns
0A
15A
30A
I →
t →
The higher C
S
value and lower R
S
value in
the IEC61000-4-2 model are more stringent
than the Human Body Model. The larger
storage capacitor injects a higher voltage
to the test point when SW2 is switched on.
The lower current limiting resistor increases
the current charge onto the test point.
DESCRIPTION

SP3220EBCY-L

Mfr. #:
Manufacturer:
MaxLinear
Description:
RS-232 Interface IC RS232 1drvr/1rcvr temp 0C to 70C