3.4 Electrical Features
Electronic function Speed-Controlled
Reversed polarity protection Rectifying diode
Max. residual current at Un IF <= 10 mA
Locked rotor protection Auto restart
Locked rotor current at Un approx. 4.200 mA
Clock signal t3/t4 at locked rotor Typical: 0,5 s / 5,0 s
Product Data Sheet DV4112/2NP-201
5/7/2012 page 8 of 11
3.5 Aerodynamic
Measurement
conditions:
Measured with a double chamber intake rig acc. to DIN EN ISO 5801.
Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C;
In the intake and outlet area should not be any solid obstruction within 0,5 m.
a.) Operation condition:
6.000 1/min at free air
flow
PWM 100 %;
Max. free-air flow (p = 0 /
= max.) 280,0 m3/h
Max. static pressure (p = max. /
=0) 395 Pa
Product Data Sheet DV4112/2NP-201
5/7/2012 page 9 of 11
3.6 Sound Data
Measurement
conditions:
Sound pressure level: 1 Meter distance between microphone and the air intake.
Sound power level: Acc. to DIN 45635 part 38 (ISO 10302)
Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 dB(A)
For further measurement conditions see section 3.5
a.) Operation condition:
6.000 1/min at free air
flow
PWM 100 % PWM min.: PWM max.:
Optimal operating point 190,0 m3/h @ 136 Pa
Sound power level at the optimal operating
point
7,0 bel(A)
Sound pressure level at free air flow,
measured in rubber bands
61,0 dB(A)
4 Environment
4.1 General
Min. permitted ambient temperature TU min. -20 °C
Max. permitted ambient temperature TU max. 65 °C
Min. permitted storage temperature TL min. -40 °C
Max. permitted storage temperature TL max. 80 °C
4.2 Climatic requirements*)
Humidity requirements humid heat, constant; according to DIN EN 60068-2-
78, 14 days
Water exposure None
Radiation exposure None
Dust requirements None
Salt fog requirements None
Harmful gas requirements None
*) Permittet application area:
The product is intended for use in sheltered rooms with controlled temperature and controlled humidity. Directly
exposure to water must be avoided.
Pollution degree 1 (according DIN EN 60664-1)
There is either no pollution or it occurs only dry, non-conductive pollution. The pollution has no negative impact.Please
require severity levels and specification parameters from the responsible development departments