88829198

17.5 mm
-
1 Relay 5A EMER8 Part number 88829198
Multifunction or mono-function
Multi
-range (7 ranges)
Multi
-voltage or single voltage
Screw terminals
LED status indicator (1 voltage present LED, 1 timer ON LED)
Option of supplying a load in parallel (EMER / EMYR)
Part numbers
Specifications
Type
Packaging
Functions
Timing
Nominal rating
Supply voltage
88829198
EMER8
Per unit
A - At -
B
-
C
-
D
-
Di
-
H
-
Ht
-
Pe
-
W
0,1→20h
5 A NO
12→240VDC/24→240VAC
Timing
Timing ranges (7 ranges)
0.1s→1s/1→10s/6→60s/1→10min/6→60min/1→10h/2→20h
Repetition accuracy with constant parameters
±
0,5 %
Drift Temperature
±
0,05 %/ °C
Drift Voltage
±
0,2 %/V
Display accuracy according to IEC/EN 61812
-1
±
10 % / 25 °C
Minimum pulse time
30 ms
Maximum reset time by denergisation
100 ms
Supply
Multi
-voltage power supply
EMAR2 : 110
-120 VAC
EMAR7 : 240 VAC
EMAR9 : 24 VAC/DC
EMER8/EMYR8:12→240VDC/24→240VAC
Operating range
EMAR2 : 93 to 132VAC
EMAR7 :
-15 % + 10 %
EMAR9 : 24 VAC
-
15 % + 10 % / 24 VDC
- 15 % + 20 %
EMER8/EMYR8 :
-15 % + 10 %
Frequency (Hz)
50 / 60 Hz
±
5 %
Max. absorbed power
EMAR2 : approx 3,2 VA 110 VAC
EMAR7 : approx. 3,2 VA 230 VAC
EMAR9 : approx. 1,2 VA (0,6 W) / 24 VAC (DC)
EMER8/EMYR8 : approx. 3,2 VA (1,5 W) / 230 VAC (DC)
Approx. 1,2 VA (0,6 W) / 24 VAC (DC)
Immunity from micro power cuts : typical
> 10 ms
Output specification
Changeover relay
1 NO : 1250 VA / 150 W
1 NC : 750 VA / 90 W
Maximum breaking current
NO : 5 A 250 VAC / 5 A 30 VDC resistive
NC : 3 A 250 VAC / 3 A 30 VDC resistive
Minimum breaking current
10 mA / 12 VDC
Voltage breaking capacity
277 VAC / 30 VDC
Electrical life (operations)
10
5
NO cycles
7 x 10
4
cycles
Mechanical life (operations cycles)
5 x 10
6
General characteristics
LED display
Green : voltage present
Yellow : timer R ON
Fixing : Symmetrical DIN rail
35 mm
Protection (IEC/EN 60529)
Casing : IP40
Connection terminals : IP20
Terminal capacity Multi
-wire with ferrule
1x0,5→4mm
2
(AWG20→AWG11)
2x0,5→2,5mm
2
(AWG20→AWG14)
Terminal capacity Single
-wire without ferrule
1x0,5→2,5mm
2
(AWG20→AWG14)
2x0,5→1,5mm
2
(AWG20→AWG16)
Stripping length (mm)
5 mm
Max. tightening torques
IEC/EN 60947
-1
0,6→0,8Nm
Temperature limits use (°C)
-
20°C→+60°C
Temperature limits stored (°C)
-
40°C→70°C
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
02/11/2015 www.crouzet.com
Relative humidity
no condensation acc. to IEC/EN 60068
-
2-30
93 %
Vibration resistance according to IEC/EN 60068
-2-6
10→55Hz,A=0.35mmpeaktopeak10xcycles,1octave/min
Weight (g)
60
Standard
Certifications
CE
-
cUL
Conforming to standards (directives BT and CEM)
IEC/EN 61812
-1
IEC/EN 61000
-6-2
IEC/EN 61000
-6-3
IEC/EN 61000
-6-4
Conformity with environmental directives
2002/95/CE : RoHS
1907/2006 : Reach
Immunity to electrostatic discharges acc.
IEC/EN 61000
-4-
2
Level III
air
±
8 kV / contact
±
4 kV
Immunity to radiated, radio
-frequency, electromagnetic
field acc. IEC/EN 61000
-4-3
Level III
10V/m(80MHz→1GHz)80%AM(1KHz)
3V/m(1.4→2GHz)80%AM(1KHz)
1V/m(2→2.7GHz)80%AM(1KHz)
Immunity to rapid transient bursts acc. to IEC/EN 61000
-4-
4
Level III
Direct
±
2 kV (power supply)
Coupling
±
1 kV (I/O)
Immunity to shock waves on power supply acc. to IEC/EN
61000-4-5
Level III
Power supply/earth
±
2 KV
Power supply input
±
1 KV
Immunity to radio frequency in common mode acc. to
IEC/EN 61000
-4-6
Level III
10V(0.15→80MHz)80%AM(1KHz)
Immunity to magnetical field acc. (IEC/EN 61000
-4-8)
50, 60 Hz 30 A/m, 1 min.
Immunity to voltage dips and breaks acc. to IEC/EN 61000
-
4-11
0 % residual voltage / 1 cycle
40 % residual voltage / 10 cycles (50 Hz) / 12 cycles (60 Hz)
70 % residual voltage / 25 cycles (50 Hz) / 30 cycles (60 Hz)
Mains
-
borne and radiated emissions acc. to IEC/EN
61000-6-3
Class B
Insulation
Insulation voltage
250 V
Insulation coordination (IEC/EN 60664
-1)
Category III, degree of pollution 3 ; up to 2000 m
Shock waves
2,5 KV (1,2 / 50
μ
s)
Breakdown voltage conforming to IEC/EN 61812
-1
2 KV / 1 min / 1 mA / 50 Hz
Insulation resistance
> 500 M
Ω
/
250 V DC / 1 min
Dimensions (mm)
Curves
A function
Function A
Delay on energisation 1 relay
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
02/11/2015 www.crouzet.com
Curves
At function
Function At
Timing on energisation with memory 1 relay
Curves
B function
Function B
Timing on impulse one shot 1 relay
Curves
C function
Function C
Timing after impulse 1 relay
Curves
D function
Function D
Flip
-flop Pause start 1 relay
Curves
Di function
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
02/11/2015 www.crouzet.com

88829198

Mfr. #:
Manufacturer:
Crouzet
Description:
Timers EMER8 TIMER 12-24VDC 24-240VAC, SPDT 5A
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet