SPECIFICATION
ORDER NO.
DC VOLTAGE (Typ.)
SAFETY MODEL NO.
RATED POWER
OUTPUT
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT
INPUT
ENVIRONMENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
SAFETY STANDARDS
SAFETY &
EMC
(Note. 6)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
PROTECTION
GC160A24- GC160A48-
GC160A24 GC160A48
GC160A12-
GC160A12
27.2V 54.4V13.6V
LED INDICATOR Charging(CC) : RED Floating charging(CV) : GREEN
85 ~ 264VAC 120 ~ 370VDC
47 ~ 63Hz
PF>0.94 / 230VAC PF>0.98 / 115VAC at full load
92.5% 94%89%
1.85A / 115VAC 1A / 230VAC
120A / 230VAC
0.75mA / 240VAC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P: 3KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH℃
274.1Khrs min. MIL-HDBK-217F(25 )℃
-30 ~ +70 (Refer to "Derating Curve")℃
20% ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH℃
±℃℃0.03% / (0~50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
175*72*35mm (L*W*H)
0.7Kg; 20pcs/15Kg/0.85CUFT(GC160Axx-R7B) 0.77Kg; 20pcs/16.4Kg/1.15CUFT(GC160Axx-AD1)
CONNECTOR
PLUG
CABLE
See page 2 ; Other type available by customer requested
See page 2 ; Other type available by customer requested
■ Features :
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A, EAC TP TC 020
OVERLOAD
Note.5
OVER VOLTAGE
90 ~ 110% rated output power
Protection type : Constant current limiting recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
160.2W 160.5W136W
Protection type : Shut down o/p voltage, re-power on to recover
UL1012 (for GC160Axx-AD1 only), TUV EN60950-1 approved
, EAC TP TC 004
Compliance to EN55032 class B, EN61000-3-2,3 FCC PART 15 / CISPR22 class B CAN ICES-3(B)-NMB-(B),, , EAC TP TC 020
Charger for lead-acid batteries (flooded,Gel and AGM and Li-ion)
batteries (lithium iron and lithium manganese) (Note.1)
2 stage charging characteristic
Universal AC input / Full range
Built-in active PFC function, PF>0.94
No load power consumption<1W
3 pole AC inlet IEC320-C14
Class power ( with earth pin)I
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Fully enclosed plastic case
2 color LED indicator for charging status
Approvals: UL / TUV / EAC / CB / FCC / CE
2 years warranty
OVER TEMPERATURE
GC160 series
160W Single Output Battery Charger
RECOMMENDED BATTERY
CAPACITY
Note.3
CURRENT (Typ.)
CONTINUOS OUTPUT
30 ~ 90Ah
5.89A
15 ~ 45Ah
2.95A
60 ~160Ah
10A
SHORT CIRCUIT
90 10 (RTH2) detect on inside ambient temperature℃± ℃
Protection type : Shut down o/p voltage, re-power on to recover
ORDER NO. OUTPUT CONNECTOR SAFETY
GC160Axx-R7B (standard model) 4pin power din TUV / CB / FCC / CE / EAC
GC160Axx-AD1 (optional model)
=R7B,AD1GC160Axx- xx=12,24,48 ;
Anderson connector UL / TUV / CB / FCC / CE / EAC
( for GC160Axx-AD1 only)
EMC IMMUNITY
EMC EMISSION
1. Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details.
2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
3. This is MeanWell's suggested range, please consult your battery manufacturer for their suggestions about maximum charging current limitation.
4. Derating may be needed under low input voltage. Please check the derating curve for more details.
5. Constant current operation region is within 50~100% rated output voltage.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
7. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
File Name:GC160-SPEC 2018-01-12