ADC1003S030_040_050_3 © IDT 2012. All rights reserved.
Product data sheet Rev. 03 — 2 July 2012 2 of 19
Integrated Design Technology
ADC1003S030/040/050
Single 10 bits ADC, up to 30 MHz, 40 Mhz or 50 MHz, with voltage
regulator
Cellular based stations
Bar
code scanner
Medical imaging
4. Quick reference data
Table 1. Quick reference data
V
CCA
= V3 to V4 = 4.75 V to 5.25 V; V
CCD
= V11 to V12 and V28 to V27 = 4.75 V to 5.25 V;
V
CCO
= V13 to V14 = 3.0 V to 5.25 V; AGND and DGND shorted together; T
amb
= 0
C to 70
C;
typical values measured at V
CCA
= V
CCD
= 5 V and V
CCO
= 3.3 V; C
L
= 15 pF and T
amb
= 25
C;
unless otherwise specified.
Symbol Parameter Conditions Min Typ Max Unit
V
CCA
analog supply voltage 4.75 5.0 5.25 V
V
CCD
digital supply voltage 4.75 5.0 5.25 V
V
CCO
output supply voltage 3.0 3.3 5.25 V
I
CCA
analog supply current - 30 35 mA
I
CCD
digital supply current - 16 21 mA
I
CCO
output supply current f
clk
= 40 MHz;
ramp input
- 1 2 mA
INL integral non-linearity f
clk
= 40 MHz;
ramp input
- 0.8 2.0 LSB
DNL differential non-linearity f
clk
= 40 MHz;
ramp input
- 0.5 0.9 LSB
f
clk(max)
maximum clock
frequency
ADC1003S030TS 30 - - MHz
ADC1003S040TS 40 - - MHz
ADC1003S050TS 50 - - MHz
P
tot
total power dissipation f
clk
= 40 MHz;
ramp input
- 235 305 mW
5. Ordering information
Table 2. Ordering information
Type number Package Sampling
frequency
(MHz)
Name Description Version
ADC1003S030TS SSOP28 plastic shrink small outline package; 28 leads;
body width 5.3 mm
SOT341-1 30
ADC1003S040TS SSOP28 plastic shrink small outline package; 28 leads;
body width 5.3 mm
SOT341-1 40
ADC1003S050TS SSOP28 plastic shrink small outline package; 28 leads;
body width 5.3 mm
SOT341-1 50