34
2707A2708
Basic Functions
Ranging Auto Manual Manual Manual Manual
Current 10A AC/DC 10A AC/DC 10A AC/DC 10A AC/DC 10A DC
Component Tests
Resistance 0.1Ω to 43MΩ 0.1Ω to 200MΩ 0.1Ω to 20MΩ 0.1Ω to 20MΩ 0.1Ω to 20MΩ
Capacitance to 20µF to 20µF to 20µF
Transistor Test √√√
Frequency Counter √√√
Temperature Probe √
Logic Probe √√
Backlight √
Common Features:
■ 2000 count
■ 0.5% DCV accuracy
■ DC voltage to 1000V
■ AC voltage to 750V
■ DC current to 10A
■ Continuity
■ Diode test
■ Drop resistant case
Features
models
2708 2707A 2706A 2704B 2703B
Excellent meters for most jobs that require flexibility, accu-
racy and speed. Value packed features make these meters
a must in every “Tool Kit
®
.”
DC Volts
Ranges 430mV, 4.3V, 43V, 1000V 200mV, 2V, 20V, 200V, 1000V
Resolution 100µV, 1mV, 10mV, 100mV, 1V
Accuracy ±(0.5% + 1 Digit)
Overload Protection 200mV Range 500V DC + AC Peak, 350V RMS Sine: All Other Ranges: 1200V DC + AC Peak, 800V RMS, Sine
Input Impedance 10MΩ
AC Volts
Ranges 430mV, 4.3V, 43V, 430V, 750V 200mV, 2V, 20V, 200V, 750V 200V, 750V,
Resolution 100µV, 1mV, 10mV, 100mV, 1V 100µV, 1mV, 10mV, 100mV, 1V 100mV, 1V
Basic Accuracy ±(1.5% + 4 Digits)
Frequency Response 50 to 100 Hz 50 to 500 Hz
Overload Protection 200mV Range: 500V DC + AC Peak, 350V RMS, Sine: All Other Ranges: 1200V DC + AC Peak, 800V RMS, Sine: 500VDC + AC Peak,
750VRMS, Sine
Input Impedance 10MΩ 4.5MΩ
DC Current
Ranges 430µA, 43mA, 430mA, 10A 200µA, 2mA, 20mA, 200mA, 2A, 10A (2A: 2706A only) 200mA, 20mA, 200mA, 10A
Resolution 0.1µA, 10µA, 100µA, 10mA 0.1µA, 1µA, 10µA, 100µA, 1mA, 10mA (1mA: 2706A only) 0.1µA, 1µA, 100µA, 10mA
Accuracy ±(0.5% + 1 Digit) ±(1% + 1 Digit): 10A Range: ±(2% + 3 Digits)
Burden Voltage 10A and 200mA range: 750mV max.; All Other Ranges: 325mV max.
Overload Protection 10A Range: Unfused; All Other Ranges: 250V Fuse
AC Current
Ranges 430µA, 43mA, 430mA, 10A 200µA, 2mA, 20mA, 200mA, 2A, 10A (2A: 2706A only) Does not apply
Resolution 0.1µA, 10µA, 100µA, 10mA 0.1µA, 1µA, 10µA, 100µA, 1mA, 10mA (1mA: 2706A only)
Accuracy ±(1.2% + 4 Digits): 10A Range: ±(2% + 4 Digits)
Frequency Response 50 to 500 Hz
Burden Voltage 10A and 200mA Range: 750mV max.; All Other Ranges: 325mV max.
Overload Protection 10A Range: Unfused; All Other Ranges: 250 V Fuse
Resistance
Ranges 430Ω, 4.3kΩ, 43kΩ, 4.3MΩ, 43MΩ 200Ω, 2kΩ, 20kΩ, 200kΩ, 2MΩ, 20MΩ, 200MΩ (200MΩ: 2707A only)
Resolution 0.1Ω, 1Ω, 10Ω, 100Ω, 1kΩ, 10kΩ 0.1Ω, 1Ω, 10Ω, 100Ω, 1kΩ, 10kΩ, 100kΩ (100kΩ: 2707A only)
Basic Accuracy 430Ω Range: ±(0.3% + 3 Digit)
200MΩ Range (2707A only): ±(5% + 10 Dgt.);
±(0.8% + 1 Digit)
4.3k - 4.3MΩ Range: ±(0.3% + 2dgt) 20MΩ Range: ±(3% + 1 Digit) 43MΩ Range: ±(1.5% + 4 Digit) 200Ω Range: ±(1% + 3 D)
Overload Protection 500V DC + AC Peak
Specifications
models
2708 2707A 2706A 2704B 2703B