2902962

1Description
Fault monitoring module
MINI MCR-SL-FM-RC-NC
© PHOENIX CONTACT
Data sheet
Fault monitoring module for evaluating and reporting group
errors of the fault monitoring system.
Supply voltages of MINI MCR-SL-PTB-FM(-SP) power termi-
nals can be monitored. Drawing off the supply is also possi-
ble. The error is reported via an N/C contact.
Features
Configurable fault monitoring module
–Configurable via DIP switch
Approval for Ex-zone 2 (nA)
Screw or spring-cage connection can be provided
WARNING: Correct usage in potentially explosive areas
The module is a category 3 item of electrical equipment. It is absolutely vital to follow the instructions provided
here during installation and observe the information in the "Safety regulations and installation notes".
Make sure you always use the latest documentation.
It can be downloaded from the product at www.phoenixcontact.net/products
.
This data sheet is valid for all products listed on the following page:
105448_en_00
2013-01-14
MINI MCR-SL-FM-RC-NC
105448_en_00 PHOENIX CONTACT 2
2Table of contents
1 Description .............................................................................................................................. 1
2 Table of contents..................................................................................................................... 2
3 Ordering data .......................................................................................................................... 3
4 Technical data ......................................................................................................................... 3
5 Safety regulations and installation notes.................................................................................. 5
5.1 Installation notes ................................................................................................................. 5
5.2 Installation in the Ex area (zone 2)............................................................................................ 5
6 Installation ............................................................................................................................... 6
6.1 Connection notes ................................................................................................................ 6
6.2 Structure ........................................................................................................................... 6
6.3 Block diagram..................................................................................................................... 6
6.4 Power supply...................................................................................................................... 6
6.5 Assembly........................................................................................................................... 7
6.6 Connecting the wires ............................................................................................................ 7
7 Fault monitoring FM................................................................................................................. 8
7.1 Fault monitoring for group error detection .................................................................................. 8
7.2 Fault monitoring for redundancy monitoring................................................................................ 8
7.3 Application options............................................................................................................... 8
8 Configuration ........................................................................................................................... 9
9 Diagnostic indicator ................................................................................................................. 9
MINI MCR-SL-FM-RC-NC
105448_en_00 PHOENIX CONTACT 3
Description Type Order No. Pcs. / Pkt.
The fault monitoring module is used to evaluate and report group errors
from the fault monitoring system and to monitor the supply voltages. The
error is reported via an N/O contact. Screw connection, standard configu-
ration.
MINI MCR-SL-FM-RC-NC 2902961 1
The fault monitoring module is used to evaluate and report group errors
from the fault monitoring system and to monitor the supply voltages. The
error is reported via an N/O contact. Spring-cage connection, standard
configuration.
MINI MCR-SL-FM-RC-SP-NC 2902962 1
3Ordering data
Accessories Type Order No. Pcs. / Pkt.
The MINI MCR-SL-PTB-FM(-SP) power terminal block is used to supply
the supply voltage to the T-connector. The FM power terminal block offers
the additional function of monitoring in combination with the fault monitor-
ing module. Screw connection.
MINI MCR-SL-PTB-FM 2902958 1
The MINI MCR-SL-PTB-FM(-SP) power terminal block is used to supply
the supply voltage to the T-connector. The FM power terminal block offers
the additional function of monitoring in combination with the fault monitor-
ing module. Spring-cage connection.
MINI MCR-SL-PTB-FM-SP 2902959 1
DIN rail connector (TBUS), 5-pos., for bridging the supply voltage, can be
snapped onto NS 35/... DIN rails according to EN60715
ME 6,2 TBUS-2 1,5/5-ST-3,81 GN 2869728 10
DIN rail power supply unit, primary-switched mode, slim design, output:
24 V DC / 1.5 A
MINI-SYS-PS-100-240AC/24DC/1.5 2866983 1
Fold up transparent cover for MINI MCR modules with additional labeling
option using insert strips and flat Zack marker strip 6.2 mm
MINI MCR DKL 2308111 10
Label for extended marking of MINI MCR modules in connection with the
MINI MCR-DKL
MINI MCR-DKL-LABEL 2810272 10
4 Technical data
Input
Description of the input Voltage input for redundancy monitoring
Voltage input signal 9.6 V DC ... 30 V DC
Output
Voltage output signal 9.6 V DC ... 30 V DC
Max. current output signal 2 A
Output description Switching output
Maximum switching voltage 30 V DC
Max. switching current 50 mA
Supply
Supply voltage range 9.6 V DC ... 30 V DC (The T connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order
No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a
35 mm DIN rail according to EN60715))
Max. current consumption < 5 mA (at 24 V DC)
Power consumption < 120 mW (at 24 V DC)
Diagnostic and status indicators
Status display Yellow LED (switching output active), red LED (error)