Product Data Sheet 412 JHHU
5/7/2012 page 5 of 10
3.2 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; Motor axis horizontal;warm-up
time before measuring 5 minutes (unless otherwise specified).In the intake and outlet area
should not be any solid obstruction within 0,5 m.
∆p = 0: corresp. to free air flow (see section 3.5)
I: corresp. to arithm. mean current value
Features Condition Symbol Values
Voltage range ∆p = 0 U 8,0 V 13,5 V
Nominal voltage ∆p = 0 U
N
12,0 V
Power consumption
∆p = 0
0001
P
1,5 W 3,2 W 4,2 W
Tolerance
+- 20,0 % +- 20,0 % +- 20,0 %
Current consumption
∆p = 0
0001
I
190 mA 270 mA 310 mA
Tolerance
+- 20,0 % +- 20,0 % +- 20,0 %
Speed
∆p = 0
0001
n
8.500 1/min 13.000 1/min 13.800 1/min
Tolerance
+- 15,0 % +- 15,0 %
+ 10 % - 15 %
Starting current
consumption
2.100 mA
3.3 Operating Data - Electrical Interface -Output
Tacho type None
Alarm type None
3.4 Electrical Features
Electronic function None
Reversed polarity protection Rectifying diode
Max. residual current at Un IF <= 50 uA
Locked rotor protection Auto restart
Locked rotor current at Un approx. 2.100 mA
Clock signal t3/t4 at locked rotor Typical: 0,16 s / 1,0 s
t3: 0,05 s... 0,37 s
t4: 0,34 s... 2,2 s