TLP700
2014-09-22
14
EN60747-5-2 Option:(D4)
Attachment : Specifications for EN60747-5-2 option: (D4)
Types : TLP700, TLP700F
Type designations for “option: (D4)”, which are tested under EN60747 requirements.
Ex.: TLP700 (D4-TP,F) D4 : EN60747 option
TP : Standard tape & reel type
F : `G`/RoHS COMPATIBLE (Note 11)
Note: Use TOSHIBA standard type number for safety standard application.
Ex.: TLP700 (D4-TP,F) → TLP700
EN60747 Isolation Characteristics
Description Symbol Rating Unit
Application classification
for rated mains voltage≤300V
rms
for rated mains voltage≤600V
rms
I-IV
I-III
—
Climatic classification
40/ 100 / 21 —
Pollution degree
2 —
Maximum operating insulation voltage
TLPxxx type
V
IORM
890
Vpk
TLPxxxFtype 1140
Input to output test voltage, method A
Vpr=1.5×V
IORM
, type and sample test
tp=10s, partial discharge<5pC
TLPxxx type
Vpr
1335
Vpk
TLPxxxFtype 1710
Input to output test voltage, method B
Vpr=1.875×V
IORM
, 100% production test
t
p
=1s, partial discharge<5pC
TLPxxx type
Vpr
1670
Vpk
TLPxxxFtype 2140
Highest permissible overvoltage
(transient overvoltage, t
pr
= 60s)
V
TR
8000 Vpk
Safety limiting values (max. permissible ratings in case of
fault, also refer to thermal derating curve)
current (input current I
F
, P
si
= 0)
power (output or total power dissipation)
temperature
Isi
Psi
Tsi
300
700
150
mA
mW
℃
Insulation resistance,
Rsi
≥10
12
≥10
11
≥10
9
Ω
=500V, Ta=25°C
=500V, Ta=100°C
=500V, Ta=Tsi
V
IO
V
IO
V
IO