RD-2405D/P

ECONOLINE
DC/DC-Converter
with 3 year Warranty
RD
EN-60950-1 Certified
Selection Guide
Output Power (%)
100
60
20
40
100500-40
85
150
Operating Temperature °C
0
80
Safe Operating Area
Input Voltage Range ±10%
Output Voltage Accuracy ±5%
Line Voltage Regulation 1.2%/1% of Vin typ.
Load Voltage Regulation 3.3V output types 20% max.
(10% to 100% full load) 5V output type 15% max.
9V, 12V, 15V, 24V output types 10% max.
Output Ripple and Noise (20MHz limited) 150mVp-p max.
Operating Frequency 20kHz min. / 50kHz typ. / 85kHz max.
Efficiency at Full Load 70% min. / 80% typ.
Minimum Load = 0% Specifications valid for 10% minimum load only.
Isolation Voltage (tested for 1 second) 1000VDC
(rated for 1 minute**) 500VAC / 60Hz
Isolation Voltage H-Suffix (tested for 1 second) 2000VDC
H-Suffix (rated for 1 minute**) 1000VAC / 60Hz
Isolation Capacitance 40pF min. / 115pF max.
Isolation Resistance 10 GΩ min.
Short Circuit Protection 1 Second
P-Suffix Continuous
Operating Temperature Range (free air convection) -40°C to +85°C (see Graph)
Storage Temperature Range -55°C to +125°C
Relative Humidity 95% RH
Package Weight 2.8g
Packing Quantity 25 pcs per Tube
MTBF (+25°C) using MIL-HDBK 217F 988 x 10
3
hours
(+85°C) using MIL-HDBK 217F 135 x 10
3
hours
Certifications
EN General Safety Report: SPCLVD1109103 EN60950-1:2006 + A12:2011
2 Watt
SIP7
Dual Output
Derating-Graph
(Ambient Temperature)
Low Cost 2W Dual Output Converter
Industry Standard SIP7 Packages
Power Sharing on Outputs
Optional Continuous Short Circuit Protected
1kVDC and 2kVDC Isolation Options
UL94V-0 Package Material
Efficiency to 86%
Features
Unregulated
Converters
}
Detailed Information see
Application Notes chapter "MTBF"
The RD series have been specifically designed for applications where dual power rails need to
be created from a single rail supply and a low cost solution is required. With efficiencies up to
85%, the full output power is available over the operating temperature range -40°C to +85°C
and the converters can be used in ambient temperatures of up to 100°C with derating. The wide
selection of industry standard input voltage and output voltage options plus an I/O-Isolation of
1kVDC or 2kVDC makes these converters suitable for many industrial applications.
Description
Specifications (measured at T
A
= 25°C, nominal input voltage, full load and after warm-up)
Refer to Application Notes
RoHS
2011/65/EU
6/6
**Any data referred to in this datasheet are of indicative nature and
based on our practical experience only. For further details, please
refer to our Application Notes.
Part Input Output Output Efficiency Max
Number Voltage Voltage Current Capacitive
SIP 7 2kV (VDC) (VDC) (mA) (%) Load
(1)
RD-xx05D (H) 5, 12, 24 ±5 ±200 75-82 ±470µF
RD-xx12D (H) 5, 12, 24 ±12 ±84 80-84 ±330µF
RD-xx15D (H) 5, 12, 24 ±15 ±66 82-86 ±330µF
RD-xx24D (H) 5, 12, 24 ±24 ±42 82-86 ±100µF
xx = Input Voltage. Other input and output voltage combinations available on request.
* add Suffix “P” for Continuous Short Circuit Protection, e.g. RD-0505D/P
* add Suffix „H“ for 2kV Isolation, e.g. RD-0505D/H, RD-0505D/HP
REV: 0/2015 E-91www.recom-power.com
RD
Typical Characteristics
RD
Series
ECONOLINE
DC/DC-Converter
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
0505
2405
1205
Deviation / Load
-10.000
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5.000
Total Output current (%)
2405
0.000
5.000
10.000
15.000
20.000
25.000
0505
1205
RD-xx05D
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
1212
2412
0512
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
2415
0515
1215
Deviation / Load
-10.000
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5.000
Total Output current (%)
0512
0.000
5.000
10.000
15.000
20.000
25.000
2412
1212
Deviation / Load
-10.000
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5.000
Total Output current (%)
2415
0.000
5.000
10.000
15.000
20.000
25.000
1215
0515
RD-xx12D RD-xx15D
Package Style and Pinning (mm)
Dual Output
12 5
RECOM
RD-0505D
****
6
4
7.05
0.51 typ.
4.10
10.20
19.65
1.27
0.25
5 x 2.54
2.0
RECOM
RD-xxxxD
****
0.51 typ.
2.54
1.00
ø
+0.15/0
2.54
Top View
Bottom View
Recommended Footprint Details
7 PIN SIP Package
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
Pin Connections
Pin # RD
1 +Vin
2 –Vin
4 –Vout
5 Com
6 +Vout
Notes
Note 1 Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter.
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
REV: 0/2015 www.recom-power.comE-92

RD-2405D/P

Mfr. #:
Manufacturer:
RECOM Power
Description:
Isolated DC/DC Converters 2W DC/DC 1kV UNREG 24Vin +/-5Vout
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union