※ In addition to the adjustment via the built-in potentiometer, the output voltage can be trimmed by applying EXTERNAL VOLTAGE.
4. Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim)
EXTERNAL VOLTAGE (DC)
PIN14 -V-signal
PIN12 PV
◎ Suitable for lead-acid batteries (flooded, Gel andAGM) and
Li-ion batteries (lithium iron and lithium manganese).
3200W Intelligent Single Output Battery Charger
DBU-3200 series
File Name:DBU-3200-SPEC 2018-08-01
OUTPUT VOLTAGE(V)
1.PMBus Communication Interface
2.Charging Curve
DBU-3200 supports PMBus Rev. 1.1 with maximum 100KHz bus speed, allowing information reading, status monitoring, output trimming, etc. For details,
※ By factory default, this charger performs the default curve which can be programmed via PMBus.
※ To disable / enable the charging curve, change to a 2 stage curve, a different curve frequently used for certain types of batteries in the industry, and
so on, please refer to the Installation Manual.
◎ Default 3 stage charging curve ◎ Embedded 3 stage charging curves
please refer to the Installation Manual.
Charge Current
Constant Current
stage 1 stage 2 stage 3
Constant Voltage Float
Start
3 Stage
Charge Voltage
100%
10%
boost
float
V
V
Orange
Charger fail if charging time
exceed charging timeout
Green
Color of LED
Status Indicator
MODEL
24V
48V
V
boost
28.8
57.6
28
56
28.4
56.8
29
58
V
float
27.6
55.2
27.2
54.4
26.8
53.6
27
54
Description
Default, programmable
Default, programmable
Pre-defined, gel batter
Pre-defined, gel batter
Pre-defined, flooded battery
Pre-defined, flooded battery
Pre-defined, AGM battery
Pre-defined, AGM battery
3. Front Panel LED Indicators & Corresponding Signal at Function Pins
LED
Green
Orange
Red
Float (stage 3)
Charging (stage 1 or stage 2)
Description
Abnormal status (OTP, OLP, Fan Fail, Charging timeout.)
V
5
EXTERNAL VOLTAGE (DC)
4.7
Non-Linear
10.4
18
24
30
DBU-3200-48
0
36
48
60
DBU-3200-24
0
CN1
+V
-V
CC
(default)
110A
55A
Note:
When using this charger unit, please configured the system with recommended
battery capacity defined by specification . Should battery capacity in use be
much smaller so that user needs to set a low current for charging, under such
condition it might cause higher current ripple.