DKA15A-12

2:1 wide input range
4:1 wide input range(option)
1000VDC I/O isolation
3000VDC I/O isolation(option)
Built-in EMI filter
Protections: Short circuit / Overload
Cooling by free air convection
Six-sided shield metal case
100% burn-in test
Low cost / High reliability
Approvals: FCC / CE
2 years warranty
SPECIFICATION
File Name:DKA15-SPEC 2018-01-15
DKA15A-05 DKA15B-05 DKA15C-05 DKA15B-12 DKA15C-12 DKA15A-15 DKA15B-15 DKA15C-15
ORDER NO.
DC VOLTAGE
CURRENT RANGE
RATED POWER
OUTPUT
SWITCHING FREQUENCY
VOLTAGE RANGE
EFFICIENCY (Typ.)
DC CURRENT
INPUT
ENVIRONMENT
SAFETY &
EMC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
WEIGHT
FILTER
PROTECTION
A: 9 ~ 18VDC B: 18 ~ 36VDC C: 36 ~ 72VDC
150KHz min.
±2.0%
±0.5%
±0.2%
50mVp-p 60mVp-p 60mVp-p
15W
±±150 ~ 1500mA ±±62.5 ~ 625mA ±±50 ~ 500mA
±5V ±12V ±15V
80% 82%
220uF
A: 1600mA B: 800mA C: 400mA
A: 30mA B: 30mA C: 15mA
110% ~ 250% rated output power
I/P-O/P:1KVDC
I/P-O/P: 100M Ohms / 500VDC / 25 / 70% RH
300Khrs min. MIL-HDBK-217F (25 )
-40 ~ +71 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-40 ~ +105 , 10 ~ 95% RH
±℃0.03% / ( 0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
50.8*25.4*11.27mm or 2"*1"*0.44" inch (L*W*H)
32g
1.All parameters are specified at normal input, rated load, 25 70% RH ambient.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
3.Line regulation is measured from low line to high line at rated load.
4.Load regulation is measured from 10% to 100% rated load.
5.Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds.
80%
Full load
No load
Pi network
82%
330uF
80%
83%
80%
Mechanical Specification
Unit: mm (inch)
Pin Configuration
Derating Curve
DKA15A-12
83% 82%
100uF
15W DC-DC Regulated Dual Output Converter
DKA15 series
Features :
Pin No.
Output
1
2
3
4
5
+Vin
-Vin
+Vout
COM
-Vout
OVER CURRENT
SHORT CIRCUIT
Protection type : Hiccup mode, recovers automatically after fault condition is removed
All output equipped with short circuit
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Ta ( )
LOAD (%)
-40 0 25 50
71
60
80
100
100
15.3 20.3
1
2
3
4
5
10.1
5.1
10.2
15.2
2.5
10.2
10.2
11.27
5.8
BOTTOM VIEW
2.5
1.0 + 0.2/-0.1ψ
VOLTAGE ACCURACY
RIPPLE & NOISE (max.)
Note.2
LINE REGULATION Note.3
LOAD REGULATION Note.4
(Note. 5)
Compliance to EN55032 Class A, FCC part 15 Class A, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A, EAC TP TC 020
PROTECTION
Fuse recommended
50.8
25.4
EMC IMMUNITY
EMC EMISSION
1200uF 1200uF 820uF 820uF 680uF 680uF
EXTERNAL CAPACITANCE LOAD (max.)
EAC TP TC 004 approved
SAFETY STANDARDS

DKA15A-12

Mfr. #:
Manufacturer:
Description:
Isolated DC/DC Converters 9-18Vin +/-12Vout 62.5-625mA, 15W
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: