Data Sheet
December 17, 2010
Naos Raptor 50A: Non-Isolated Power Modules
5 – 14Vdc input; 0.6Vdc to 2.0Vdc Output; 50A Output Current
* UL is a registered trademark of Underwriters Laboratories, Inc.
CSA is a registered trademark of Canadian Standards Association.
VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
** ISO is a registered trademark of the International Organization of Standards
Document No: DS10-004 ver. 1.06
PDF name: NSR050A0X432_ds.pdf
Features
Compliant to RoHS EU Directive 2002/95/EC (Z
versions)
Compatible in a Pb-free or SnPb wave-soldering
environment (Z versions)
Wide input voltage range (5Vdc-14Vdc)
Output voltage programmable from 0.6Vdc to
2.0Vdc via external resistor
Tunable Loop to optimize dynamic output voltage
response
Fixed switching frequency
Output overcurrent protection (non-latching)
Over temperature protection
Over voltage protection – Hiccup Mode
Remote On/Off
Power Good Signal
Small size: 36.8 mm x 27.9 mm x 20.1 mm
(1.45 in. x 1.10 in. x 0.79 in)
Wide operating temperature range (0°C to 70°C)
UL* 60950 Recognized, CSA
C22.2 No. 60950-00
Certified, and VDE
0805 (EN60950-1 3
rd
edition)
Licensed
ISO** 9001 and ISO 14001 certified manufacturing
facilitiesISO** 9001 and ISO 14001 certified
manufacturing facilities
Applications
Distributed power architectures
Intermediate bus voltage applications
Telecommunications equipment
Servers and storage applications
Networking equipment
Description
The Naos Raptor 50 SIP power modules are non-isolated dc-dc converters in an industry standard package that can
deliver up to 50A of output current with a full load efficiency of 87% at 1.8Vdc output voltage (V
IN = 12Vdc). These
modules operate over a wide range of input voltage (V
IN
= 5Vdc-14Vdc) and provide a precisely regulated output
voltage from 0.6dc to 2.0Vdc, programmable via an external resistor. Features include remote On/Off, adjustable
output voltage, over current, and over voltage protection. A new feature, the Tunable Loop, allows the user to
optimize the dynamic response of the converter to match the load.
RoHS Compliant
Data Sheet
December 17, 2010
Naos Raptor 50A: Non Isolated Power Module:
5 – 14Vdc input; 0.6Vdc to 2.0Vdc Output; 50A output current
LINEAGE POWER 2
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.
Parameter Device Symbol Min Max Unit
Input Voltage
Continuous All V
IN
-0.3 15 Vdc
Operating Ambient Temperature All T
A
0 70 °C
(see Thermal Considerations section)
Storage Temperature All T
stg
-55 125 °C
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Parameter Device Symbol Min Typ Max Unit
Operating Input Voltage All V
IN
5 12 14 Vdc
Maximum Input Current All I
IN,max
22.5 Adc
(V
IN
= V
IN, min
to V
IN, max
, I
O
=I
O, max
V
O,set
= 2Vdc)
Input No Load Current V
O,set
= 0.6 Vdc I
IN,No load
140 mA
(V
IN
= 12Vdc, I
O
= 0, module On) V
O,set
= 1.8Vdc I
IN,No load
200 mA
Input Stand-by Current All I
IN,stand-by
16 mA
(V
IN
= 12Vdc, module disabled)
Inrush Transient All I
2
t 1 A
2
s
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; V
IN, min
to
V
IN, max,
I
O
= I
Omax
; See Test configuration section)
All 172 mAp-p
Input Ripple Rejection (120Hz) All 48 dB
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to being
part of a complex power architecture. To preserve maximum flexibility, internal fusing is not included, however, to
achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-
acting fuse with a maximum rating of 30A (see Safety Considerations section). Based on the information provided in
this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be
used. Refer to the fuse manufacturer’s data sheet for further information.
Data Sheet
December 17, 2010
Naos Raptor 50A: Non Isolated Power Module:
5 – 14Vdc input; 0.6Vdc to 2.0Vdc Output; 50A output current
LINEAGE POWER 3
Electrical Specifications (continued)
Parameter Device Symbol Min Typ Max Unit
Output Voltage Set-point (with 0.1% tolerance for
external resistor used to set output voltage)
All V
O, set
-1.0 +1.0 % V
O, set
Output Voltage All V
O, set
-2.0
+2.0 % V
O, set
(Over all operating input voltage, resistive load, and
temperature conditions until end of life)
Adjustment Range All V
O
0.6 2.0 Vdc
Selected by an external resistor
Output Regulation (for V
O
< 2.0V)
Line (V
IN
=V
IN, min
to V
IN, max
) All
9 mV
Load (I
O
=I
O, min
to I
O, max
) All
12 mV
Output Ripple and Noise on nominal output
(V
IN
=V
IN, nom
and I
O
=I
O, min
to I
O, max
,
Cout = 0μF)
Peak-to-Peak (5Hz to 20MHz bandwidth) Vo = 0.6V
30 mV
pk-pk
Peak-to-Peak (5Hz to 20MHz bandwidth) Vo = 1V
30 mV
pk-pk
Peak-to-Peak (5Hz to 20MHz bandwidth) Vo = 1.5V
40 mV
pk-pk
Peak-to-Peak (5Hz to 20MHz bandwidth) Vo = 1.8V
40 mV
pk-pk
External Capacitance
1
Without the Tunable Loop
(combination of 500μF ceramic and 3760μF polymer) All C
O, max
0
4260 μF
With the Tunable Loop
ESR 0.15 m All C
O, max
0
4000 μF
ESR 10 m All C
O, max
0
10000 μF
Output Current All I
o
0
50 Adc
Output Current Limit Inception (Hiccup Mode ) All I
O, lim
146 % I
o
Output Short-Circuit Current All I
O, s/c
5.54
Arms
(V
O
250mV) ( Hiccup Mode )
Efficiency V
O
= 0.6Vdc η 72.5 %
V
IN
= V
IN, nom
, T
A
=25°C V
O
= 1Vdc η 80.6 %
I
O
=I
O, max ,
V
O
= V
O,set
V
O
= 1.2Vdc η 83.1 %
V
O
= 1.5Vdc η 85.4 %
V
O
= 1.8Vdc η 87.1 %
Switching Frequency All f
sw
500
kHz
Dynamic Load Response
(dIo/dt=10A/μs; V
IN
= V
IN, nom
; V
out
= 1.8V, T
A
=25°C)
Load Change from Io= 0% to 50% of Io,max;
Co = 0
Peak Deviation All V
pk
360 mV
Settling Time (Vo<10% peak deviation)
All t
s
40
μs
Load Change from Io= 50% to 0%of Io,max:
Co = 0
Peak Deviation All V
pk
520 mV
Settling Time (Vo<10% peak deviation)
All t
s
40
μs
1
External capacitors may require using the new Tunable Loop feature to ensure that the module is stable as well as
getting the best transient response. See the Tunable Loop section for details.

NSR050A0X432Z

Mfr. #:
Manufacturer:
Description:
Non-Isolated DC/DC Converters 50A 5-14Vin .6-2Vout Positive Logic SIP
Lifecycle: