JV-N
SPECIFICATIONS
COMPACT FLAT
POWER RELAY FOR
HEATER LOADS
JV-N RELAYS
22
16
10.9
.866
.630
.429
Compliance with RoHS Directive
FEATURES
• High 16 A capacity
The contacts are high capacity 16A,
125 V AC.
• Compact, flat type with low 10.9 mm
.429 inch height
Compact flat type with low surface area
of 16 × 22 mm .630 × .866 inch and
height of 10.9 mm .429 inch.
• High sensitivity at 200 mW
High sensitivity at 200 mW coil power
consumption.
• Represses contact terminal heat
The contact terminals are larger and
thicker compared to the existing JV relay.
This limits the rise in temperature of the
terminals when there is a large current
flowing to approx. 28°C 62°F (normal
current of 16 A).
• Conforms to the various safety
standards
UL/CSA, TÜV approved.
About Cd-free contacts
We have introduced Cadmium free type
products to reduce Environmental
Hazardous Substances.
(The suffix “F” should be added to the
part number)
Please replace parts containing
Cadmium with Cadmium-free products
and evaluate them with your actual
application before use because the life of
a relay depends on the contact material
and load.
Contact
Coil
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Excluding contact bounce time
*
2
Excluding contact bounce time, without diode
*
3
By resistive method; nominal voltage applied to the coil; contact carrying current:
16A, at 70°C 158°F
*
4
Nominal voltage applied to the coil, at 60°C 140°F
*
5
Half-wave pulse of sine wave: 11 ms; detection time: 10 µs
*
6
Half-wave pulse of sine wave: 6 ms
*
7
Detection time: 10 µs
*
8
Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT.
Characteristics
Arrangement 1 Form A
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Max. 100 mΩ
Contact material AgSnO2 type
Rating
(resistive
load)
Nominal switching
capacity
16 A 125 V AC, 10 A 277 V AC
10 A 30 V DC, 10 A 125 V AC
Max. switching power 2,770 VA, 300 W
Max. switching voltage 277 V AC, 30 V DC
Max. switching current 16 A (AC 125 V), 10 A (DC)
Min. switching capacity
#1
(Reference value)
100 mA, 5 V DC
Expected life (min. ope.)
Mechanical (at 180 cpm)
2×10
7
Electrical
at resistive
load
(at 20 cpm)
Sealed
type
16 A 125 V AC 3×10
4
10 A 30 V DC 10
5
Flux-resistant type
10 A 125 V AC
10
5
Nominal operating power
200 mW (DC 4.5 to 48 V)
600 mW (DC 100 V)
Max. operating speed 20 cpm
Operate time*
1
(at nominal voltage)
Max. 12 ms (DC 4.5 V to 48 V)
Max. 8 ms (DC 100 V)
Release time*
2
(at nominal voltage) Max. 5 ms
Initial insulation resistance Min. 1,000 MΩ (at 500 V DC)
Initial breakdown
voltage
(Detection
current: 10 mA
Between open
contacts
1,000 Vrms for 1 min.
Between contacts
and coil
2,500 Vrms for 1 min.
Surge voltage between contact and
coil
4,500 V
Temperature rise
Max. 45°C (DC 4.5 V to 48 V) *
3
Max. 55°C (DC 100 V)*
4
Conditions in case of operation,
transport and storage*
8
Ambient temperature
–40 to 70°C –40 to 158°F
(DC 4.5 to 48 V)
–40 to 60°C –40 to 140°F
(DC 100V)
Humidity: 5 to 85 % R.H.
(Note freezing and condensing
at low temperature)
Air pressure: 86 to 106 kPa
Shock resistance
Functional 200 m/s
2
{20G}*
5
Destructive 1,000 m/s
2
{100G}*
6
Vibration
resistance
Functional
10 to 55 Hz *
7
at double amplitude of 1.6 mm
Destructive
10 to 55 Hz at double
amplitude of 2 mm
Unit weight Approx. 8g .28 oz