SAC-3P-M12MS/ 0,6-PUR/M12FS P Order No.: 1442803
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1442803
PHOENIX CONTACT Inc., USA Page 2 / 5
http://www.phoenixcon.com May 5, 2011
Insulation resistance ≥ 100 MΩ
Length of cable 0.6 m
Ambient temperature (operation) -25 °C ... 90 °C (Male connector / female connector)
General characteristics
Standards/regulations M12 connector IEC 61076-2-101
Coding A - standard
Surge voltage category II
Pollution degree 3
Degree of protection IP65/IP68/IP69K
Insertion/withdrawal cycles ≥ 100
Contact material CuSn
Contact surface material Ni/Au
Contact carrier material TPU GF
Material of grip body TPU, hardly inflammable, self-extinguishing
Material, knurls Polyamide
Sealing material NBR
Status display No
Conductor data
Cable type PUR halogen-free black
Cable type (abbreviation) PUR
Cable abbreviation Li9Y11Y
UL AWM Style 20549
Conductor cross section 0.34 mm²
AWG signal line 22
Conductor structure signal line 42x 0.10 mm
Core diameter including insulation 1.27 mm ±0.02 mm
Thickness, insulation ≥ 0.21 mm (Core insulation)
Approx. 0.8 mm (Outer cable sheath)
External cable diameter 4.4 mm ±0.15 mm
Wire colors Brown, blue, black
External sheath, color Black-gray RAL 7021
Insulation resistance ≥ 100 GΩ*km (at 20°C)
Conductor resistance max. 58 Ω/km (at 20°C)
Nominal voltage, conductor ≤ 300 V