2210-T210-K0M1-H131-32A

Thermal-Magnetic Circuit Breaker 2210-T2...
www.e-t-a.de
1812
1
1
Description
Typical applications
Ordering information
Technical data
One, two and three pole thermal-magnetic circuit breakers with trip-free
mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934).
Featuring a combi-foot design for both symmetric and asymmetric rail
mounting. Available with auxiliary contact (1 x N/O or 1 x N/C) for status
signalling. Two and three pole models are internally linked to ensure that
both/all poles trip in the event of an overload on one pole, even if the
actuator is held in the ON position. This CBE can be supplied in current
ratings up to 32 A with a choice of characteristic curves. All screw
terminals are recessed for safety. Approved to CBE standard EN 60934
(IEC 60934).
Process control equipment, robotics, machine tool control,
communications systems, instrumentation.
2210-T2..
1-pole 3-pole
Type No.
2210 single and multipole thermal-magnetic circuit breaker
Mounting
T rail mounting
Actuator design
2 toggle
Number of poles
1 single pole protected
2 2-pole protected
3 3-pole protected
Accessories
0 without accessories
Terminal design (main contacts)
K0 screw terminals
Characteristic curve
F1 fast acting: therm.1.01-1.4xI
N
;
magn.2-4xI
N
DC (DC only)
F2 fast acting: therm.1.01-1.4xI
N
;
magn.3,5-6,5xI
N
AC/4,5-8,5xI
N
DC
M1 standard delay: therm. 1.01-1.4xI
N
;
magn. 6-12xI
N
AC, 7.8-15.6xI
N
DC
T1 delayed: therm. 1.01-1.4xI
N
; magn. 10-20xI
N
AC
Auxiliary contact design
H without intermediate position
Auxiliary contacts
1 with auxiliary contacts
2 auxiliary contacts on pole 1 only
(multipole devices)
Auxiliary contact function (see diagrams)
2 1 N/O contact
3 1 N/C contact
Auxiliary contact - terminal design
1 screw terminals
Current ratings
0.1...32 A
2210 - T 2 1 0 - K0 M1- H 1 2 1 - 10 A ordering example
For further details please see chapter: Technical Information
Voltage rating AC 250 V; 3 AC 433 V (50/60 Hz); DC 65 V
(UL: AC 277/480 V; DC 65 V)
Current rating range 0.1...32 A for curves M1, T1
0.1...16 A for curves F1, F2
Auxiliary circuit 1 A, AC 240 V / DC 65 V, resistive
(min. 10 V / 10 mA)
Typical life
3 AC 433 V; AC 250 V: 0.1...25 A
10,000 operations at 1 x I
N
, inductive
DC 65 V: 0.1...32 A
10,000 operations at 1 x I
N
, inductive
3 AC 433 V; AC 250 V: 32 A
6,000 operations at 1 x I
N
, resistive
Ambient temperature -30...+60 °C (-22...+140 °F) T 60
Insulation co-ordination rated impulse pollution
(IEC 60664 and 60664 A) withstand voltage degree
2.5 kV 2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A) test voltage
operating area AC 3,000 V
main/aux. circuit AC 3,000 V
pole/pole AC 1,500 V
Insulation resistance > 100 MΩ (DC 500 V)
Interrupting capacity I
cn
0.1...5 A 400 A
6...32 A 800 A
curves F1, F2, M1, T1: 0.1...16 A 2,500 A (at DC 32 V)
Interrupting capacity (UL 1077)
Degree of protection operating area IP30
(IEC 60529/DIN 40050) terminal area IP20
Vibration curves F1, F2: 3 g (57-500 Hz), ± 0.23 mm (10-57 Hz)
curves M1, T1: 5 g (57-500 Hz), ± 0.38 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
Shock curves F1, F2: 25 g (11 ms), directions 1, 2, 3, 4, 5
10 g (11 ms), direction 6
curves M1, T1: 25 g (11 ms), directions 1, 2, 3, 4, 5
20 g (11 ms), direction 6
to IEC 60068-2-27, test Ea
Corrosion 96 hours at 5 % salt mist
to IEC 60068-2-11, test Ka
Humidity 240 hours at 95 % RH
to IEC 60068-2-78, test Cab
Mass approx. 60 g per pole
I
N
0.1...16 A 20...25 A
AC 277 V 1-pole 5,000 A 2,000 A
AC 277/480 V
2-/3-pole 5,000 A 2,000 A
DC 65 V 2,000 A 2,000 A
Preferred types Standard current ratings (A)
1-pole 0.5 1 2 3 4 5 6 8 10 16 20
2210-T210-K0M1-H121-
x x x x x x x x x x x
2-pole 0.5 1 2 3 4 5 6 8 10 16 20
2210-T220-K0M1-H221-
x x x x x x
Preferred types
Thermal-Magnetic Circuit Breaker 2210-T2...Thermal-Magnetic Circuit Breaker 2210-T2...
www.e-t-a.de
1812
2
1
Installation drawing
Dimensions
12A
M1
Si-terminal M3
max. 1.5 mm
2
(AWG 16) (rigid conductor)
tightening torque 0.5 Nm
.295
12-14
.472-.551
.354-.472
9-12
unit I
unit II
unit III
44
30.5
18
12.5
12.5
40
5.5
37.5
OFF
ON
78.5
12.5
20
Si
1
Si
2
12
15
88.5
42.5
7.5
5.5
11.5
25
slot fitting labels from
Phoenix
Weidmüller
Wieland
G-profile
EN 50035-G32
symmetric rail
EN 50022-35x7.5
EN 50022-35x15/1.5
main contact terminal
max. 6 mm
2
(AWG 10)
(rigid conductor)
tightening torque 0.5 Nm
12A
M1
45
.787
1.77
.217
1.67
1.57
.472
.591
toggles linked
for multipole
devices
11.5
.453
1.73
3.09
3.48
.709
.984
1.20
1.48
.453
.492 .492
.492
.217
12A
M1
Si
1
Si
2
operating area
(reinforced insulation)
mounting area
Standard current ratings and typical internal resistance values
This is a metric design and millimeter dimensions take precedence (
mm
)
inch
Approvals
Current rating (A) Internal resistance (Ω)
F1 F2 M1 T1
fast acting
for DC only
fast acting
delay for
AC + DC
standard for
AC+DC
delayed low
resistance
for AC only
0.1 162 162 92 81
0.2 39.3 39.3 26.1 24.2
0.3 17.5 17.5 11.6 10.4
0.4 9.2 9.2 6.6 6.0
0.5 6.8 6.8 4.1 3.9
0.6 4.2 4.2 3 2.7
0.8 2.8 2.8 1.65 1.53
1 1.6 1.6 1.10 0.98
1.5 0.78 0,78 0.47 0.42
2 0.42 0,42 0.28 0.24
2.5 0.26 0.26 0.183 0.17
3 0.18 0.18 0.124 0.12
4 0.12 0.12 0.077 0.073
5 0.092 0.092 0.063 0.055
6 0.054 0.054 0.045 0.039
8 0.025 0.025 ≤ 0.02 ≤ 0.02
10 0.022 0.02 ≤ 0.02 ≤ 0.02
12 ≤ 0.02 ≤ 0.02 ≤ 0.02 ≤ 0.02
16 ≤ 0.02 ≤ 0.02 ≤ 0.02 ≤ 0.02
20 - - ≤ 0.02 ≤ 0.02
25 - - ≤ 0.02 ≤ 0.02
32 - - ≤ 0.02 ≤ 0.02
Authority Standard Rated voltage Current ratings
VDE IEC/EN
60934
3 AC 433 V
AC 250 V
DC 65 V
0.1 A…32 A
0.1 A…32 A
0.1 A…32 A
UL UL 1077 AC 277/480 V
AC 277 V
DC 65 V
0.1 A…32 A
0.1 A…32 A
0.1 A…32 A
CSA C22.2 No
235
AC 277/480 V
AC 277 V
DC 65 V
0.1 A…32 A
0.1 A…32 A
0.1 A…32 A
CQC GB 17701 AC 250/433 V
AC 250 V
DC 65 V
0.1 A…32 A
0.1 A…32 A
0.1 A…32 A
DNV GL IEC 60934,
DNVGL-
CG 0339
3 AC 433 V
AC 250 V
DC 65 V
0.1 A…32 A
0.1 A…32 A
0.1 A…32 A
KTL KC60934
AC 250 V, 1-pole
AC 433 V, 2-pole
0.1 A...16 A
0.1 A...16 A
Thermal-Magnetic Circuit Breaker 2210-T2...
www.e-t-a.de
1812
3
1
Thermal-Magnetic Circuit Breaker 2210-T2...
Trip time in seconds
Trip time in seconds
Trip time in seconds
-F1 0.1…16 A DC only
0.001
124681020
40
10000
1000
100
10
1
0.1
0.01
6080100
AC/ DC
1)
10000
0.001
0.001
1000
100
10
1
0.1
0.01
10000
1000
100
10
1
0.1
0.01
-F2 0.1…7.5 A
AC/ DC
1)
-30 °C
-22 °F
+23 °C
+73.4 °F
+60 °C
+140 °F
… times rated current
… times rated current
… times rated current
1)
Magnetic tripping currents are increased by 30% on DC supplies.
1246810 20 406080100
1246810 20 406080100
-F2 8…16 A
Typical time/current characteristicsInternal connection diagrams
OFF position ON position
N/O contact
N/C contact
0I 113
2
0I 111
2
I
>
0I
1
13
2
0I 111
2
line line
line line
(Si)
(Si)
(Si) (Si)
(Si) (Si)
12 12
(Si) (Si)
14 14
I
>
I
>
I
>
...-H131-...
...-H121-...
56
1
2
4
3
Shock directions

2210-T210-K0M1-H131-32A

Mfr. #:
Manufacturer:
E-T-A Circuit Breakers
Description:
Circuit Breakers 1077, 1P, DM, 277VAC/65VDC,M1, 1NC AUX, 32A
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union