Thermal-Magnetic Circuit Breaker 2210-T2...
www.e-t-a.de
1812
5
1
Thermal-Magnetic Circuit Breaker 2210-T2...
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications
without notice is reserved.Product markings may not be exactly as the ordering codes.
Errors and omissions excepted.
Accessories
Art.-Nr. Y 308 498 01
IEC 664 500 V/100 A (40 °C)
Art.-Nr. Y 308 498 01
IEC 664 500 V/100 A (40 °C)
marking 4 x on busbar
79 x 12.5 = 987.5
12.5
3
4.6
14.7
1.5
30.7
±0.4
16
Art.-Nr. Y 308 499 01
IEC 664 500 V/100 A (40 °C)
Art.-Nr. Y 308 499 01
IEC 664 500 V/100 A (40 °C)
marking 4 x on busbar
79 x 12.5 = 987.5
3
±0.2
16
L2
L1
L1
L2
L1
L1
L2
L2
L1
L1
L2
L2
L1
L1
L2
L2
L1
L1
L2
L2
L1
L1
L2
L2
L1
L1
L2
L2
L1
L1
L2
L1
L2
L2
L1
995
+2
995
+2
15.8
33,3
±0.4
17.3
~2.76
Connector bus links -K10
X210 589 01/ 2.5 mm
2
, (AWG 14) (black) up to 20 A max. load
X210 589 02/ 1.5 mm
2
, (AWG 16) (brown) up to 13 A max. load
50 pin lugs to
DIN 46230
tinned copper
ø2.5
.099
~70
79 x 12.5 = 987.5
12.5
3
±0.2
1.5
20
-1
16
-1
14.7
4.6
Busbar 1-pole, 90°
X 222 540 01
The one metre long busbars can be cut to suitable lengths.
Plug-on caps can be fitted on the ends to provide brush
contact protection.
I
max
- busbar 100 A (40 °C)
.118
±.008
.492
79 x .492 = 38.878
.579
.181
.059
.630
-.039
.787
-.039
.118
.492
79 x .492 = 38.878
79 x .492 = 38.878
39.173
+.079
.630
.181
.579
1.209
±.016
.059
39.173
+.079
.630
12.5
.492
.118
±.008
1.5
.059
.622
.681
1.311
±.016
Elektrotechnische Apparate GmbH
D-90418 Altdorf bei Nürnberg
Elektrotechnische Apparate GmbH
D-90418 Altdorf bei Nürnberg
Busbar 1-pole
308 498 01
I
max
- busbar 100 A (40 °C)
Plug-on cap, 1-pole
Y 307 851 01
Busbar 2-pole
Y 308 499 01
I
max
- busbar 100 A (40 °C)
Elektrotechnische Apparate GmbH
D-90418 Altdorf bei Nürnberg
Elektrotechnische Apparate GmbH
D-90418 Altdorf bei Nürnberg
Plug-on cap, busbar 2/3-pole
Y 308 506 01
Plug-on cap, 1-pole
Y 307 851 01
This is a metric design and millimeter dimensions take precedence (
mm
)
inch
Supply terminal
Y 308 503 01
I
max
63 A with 1-pole busbar,
50 A with multipole busbar
Max. tightening torque of terminal screw 2 Nm
Max. cable cross section: 25 mm
2
/ single strand
16 mm
2
/ multistrand
with wire end ferrule
Art.-Nr. Y 308 500 01
IEC 664 500 V/100 A (40 °C)
Art.-Nr. Y 308 500 01
IEC 664 500 V/100 A (40 C)°
marking 4 x on busbar
80 x 12.5 = 1000
12.5
3
±0.2
L3
L1
L2
L2
L2
L3
L3
L1
L2
L2
L1
L3
L3
L1
L2
L2
L2
L2
L1
L3
L3
L1
L2
L2
L1
L3
L3
L1
L2
L2
L1
L3
L3
L2
L2
L2
1010
+2
15.8
17.3
1.5
18.4
3
16.2
33.7
13
16
39.764
+.079
.630
.492
118
±.0082
80 x .492 = 39.370
.622
.681
33,3
±0.4
1.311
±.016
1.5
.059
.059
.118
.512
1.327
.638
.724
Elektrotechnische Apparate GmbH
D-90418 Altdorf bei Nürnberg
Elektrotechnische Apparate GmbH
D-90418 Altdorf bei Nürnberg
Busbar 3-pole
Y 308 500 01
I
max
- busbar 100 A (40 °C)
Plug-on cap, busbar 2/3-pole
Y 308 506 01
Caution:
When using multipole busbars please leave at least one pole’s
width between two adjacent line entry terminals.