AXL E PB DI8 DO4 2A M12 6P
8438_en_03 PHOENIX CONTACT 4
General data
Housing material Pocan
®
Color anthracite
Weight 480 g
Ambient temperature (operation) -25 °C ... 60 °C
CAUTION: Risk of burns
If the device is used at an ambient temperature above50°C, the contact temperature of metal surfaces may exceed70°C.
Ambient temperature (storage/transport) -25 °C ... 85 °C
Permissible humidity (operation) 5 % ... 95 %
Permissible humidity (storage/transport) 5 % ... 95 %
Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protection IP65/IP67
Protection class III, IEC 61140, EN 61140, VDE 0140-1
Connection data
Connection method M12 connector
Interface PROFIBUS DP
Number 2
Connection method 2x M12 connectors, B-coded
Designation connection point Copper cable
Number of positions 5
Transmission speed 9,6 kBit/s ... 12 MBit/s (Automatic baud rate detection)
Transmission physics PROFIBUS-DP-compliant copper cable
PROFIBUS DP
Equipment type PROFIBUS slave
PROFIBUS protocols DP V1
Supply: Module electronics and sensors (U
S
)
Connection method M12 connector (T-coded)
Number of positions 4
Supply voltage 24 V DC
Nominal supply voltage range 18 V DC ... 31.2 V DC (including all tolerances, including ripple)
Typical current consumption 110 mA ±15 % (at 24 V DC)
Current consumption max. 12 A
Supply: Actuators (U
A
)
Connection method M12 connector (T-coded)
Number of positions 4
Supply voltage 24 V DC
Nominal supply voltage range 18 V DC ... 31.2 V DC (including all tolerances, including ripple)
Typical current consumption 30 mA ±15 % (at 24 V DC)
Current consumption max. 12 A
AXL E PB DI8 DO4 2A M12 6P
8438_en_03 PHOENIX CONTACT 5
Digital inputs
Number of inputs 8 (EN 61131-2 types 1 and 3)
Connection method M12 connector, double occupancy
Connection method 2, 3, 4-wire
Nominal input voltage 24 V DC
Nominal input current typ. 3 mA
Sensor current per channel typ. 0.75 mA (from U
S
)
Total sensor current max. 0.6 A (per device)
Input voltage range "0" signal -30 V DC ... 5 V DC
Input voltage range "1" signal 11 V DC ... 30 V DC
Input filter time < 1000 µs
Permissible conductor length to the sensor 30 m
Overload protection, short-circuit protection of sensor supply Yes
Digital outputs
Number of outputs 4
Connection method M12 connector, (A-coded)
Connection method 2, 3-wire
Nominal output voltage 24 V DC (from voltage U
A
)
Maximum output current per channel 2 A
Nominal load, ohmic 12 W (48 ; with nominal voltage)
Nominal load, inductive 12 VA (1.2 H; 48 ; with nominal voltage)
Signal delay max. 150 µs (when switched on)
max. 200 µs (when switched off)
Switching frequency max. 5500 per second (with at least 50mA load current)
Switching frequency max. 1 per second (with inductive load)
Limitation of the voltage induced on circuit interruption -28 V ... -17 V
Output voltage when switched off max. 1 V
Output current when switched off max. 20 µA
Behavior with overload Auto restart
Reverse voltage resistance to short pulses Reverse voltage proof
Overcurrent shut-down min. 2.2 A
Overload protection, short-circuit protection of outputs Electronic
Configuration data
ID number 0E5F
Input address area 8 Bit
Output address area 8 Bit
AXL E PB DI8 DO4 2A M12 6P
8438_en_03 PHOENIX CONTACT 6
Electrical isolation/isolation of the voltage areas
Test section Test voltage
24 V supply (communications power and sensor supply, digital inputs)/
bus connection
500 V AC, 50 Hz, 1 min
24 V supply (communications power and sensor supply, digital inputs)/FE 500 V AC, 50 Hz, 1 min
Bus connection / FE 500 V AC, 50 Hz, 1 min
24 V supply (actuator supply, digital outputs)/
24 V supply (communications power and sensor supply, digital inputs)
500 V AC, 50 Hz, 1 min
24 V supply (actuator supply, digital outputs)/bus connection 500 V AC, 50 Hz, 1 min
24 V supply (actuator supply, digital outputs)/FE 500 V AC, 50 Hz, 1 min
Mechanical tests
Vibration resistance in acc. with EN60068-2-6/IEC60068-2-6 5g
Shock in acc. with EN60068-2-27/IEC60068-2-27 30g, 11 ms period, half-sine shock pulse
Continuous shock according to EN60068-2-27/IEC60068-2-27 10g
Conformance with EMC Directive 2004/108/EC
Noise immunity test in accordance with EN 61000-6-2
Electrostatic discharge (ESD) EN61000-4-2/IEC61000-4-2 Criterion B; 6 kV contact discharge, 8 kV air discharge
Electromagnetic fields EN61000-4-3/IEC61000-4-3 Criterion A; Field intensity: 10 V/m
Fast transients (burst) EN61000-4-4/IEC61000-4-4 Criterion B, 2kV
Transient surge voltage (surge) EN61000-4-5/IEC61000-4-5 Criterion B; DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
Conducted interference EN61000-4-6/IEC61000-4-6 Criterion A; Test voltage 10 V
Noise emission test as per EN 61000-6-4
Radio interference properties EN 55022 Class A
Approvals
For the latest approvals, please visit phoenixcontact.net/products.

2701502

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
Terminal Block Interface Modules AXL E PB DI8 DO4 2A M12 6P
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet