B82559A9153A020

4 02/16
Please read Cautions and warnings and
Important notes at the end of this document.
Taping and packing
Tape:
Reel:
Height (mm) Packing unit
component h cavity H per reel
9.8 12.5 130
10.7 12.5 130
12.1 13.9 115
14.1 15.9 100
Dimensions in mm
Dimensions in mm
B82559*A020ERU chokes
ERU 20
Helically woundH
5 02/16
Please read Cautions and warnings and
Important notes at the end of this document.
B82559*A020ERU chokes
ERU 20
Technical data and measuring conditions
Characteristics and ordering codes
Rated inductance L
R
Measured at 100 kHz, 0.1 V, +25 °C
Inductance tolerance r10%
Saturation current I
Sat
Current that will result in an approximately 10% drop in
the inductance values at the specified temperature
DC resistance R
DC
Measured at +25 °C
Self-resonant frequency ! 2 MHz
High voltage: N1 - core 200 V DC, 1 s
Solderability
(test of wettability of the pins)
(245 r5) °C, (3 r0.3) s,
wetting of soldering area t95%
(based on IEC 60068-2-58, solder bath method)
Resistance to soldering heat To JEDEC J-STD 020D (Tc: +245 °C on pin)
Operating temperature 40 °C … +150 °C
Storage conditions (packaged) –25 °C … +40 °C, d75% RH
L
R
PH
I
sat, 25°C
A
I
sat, 100°C
A
R
DC
(max)
m:
R
DC
(typ)
m:
Height h
(nom.)
mm
Approx.
weight
g
Ordering code
1.0 50.0 45.0 0.65 0.55 9.8 15.7 B82559A2102A020
1.5 50.0 43.0 0.90 0.80 10.7 17.6 B82559A3152A020
2.2 43.0 38.0 1.20 1.00 12.1 19.8 B82559A4222A020
3.3 34.0 29.0 1.50 1.30 14.1 22.5 B82559A5332A020
4.7 22.0 19.0 2.40 2.15 9.8 15.7 B82559A4472A020
6.8 19.0 16.5 2.90 2.70 9.8 16.3 B82559A5682A020
10.0 18.3 16.0 3.90 3.70 10.7 18.1 B82559A7103A020
15.0 15.3 13.5 4.95 4.65 12.1 19.7 B82559A9153A020
20.0 14.3 12.0 6.40 5.70 14.1 22.5 B82559A0203A020
29.0 11.0 9.5 7.10 6.65 14.1 23.9 B82559A0293A020
35.0 9.3 7.5 7.10 6.65 14.1 23.9 B82559A0353A020
Helically wound
6 02/16
Please read Cautions and warnings and
Important notes at the end of this document.
B82559*A020
ERU 20
Inductance L versus DC load current I
DC
The temperature rise 'T is measured at an am-
bient temperature of +25 °C. A current is applied
for 30 minutes and the temperature is measured
via a thermocouple placed on top of the device.
No forced air cooling is applied.
The inductance vs current curves are generated
by measuring the inductors at +25 °C and
+100 °C.
B82559A3152A020
B82559A2102A020 B82559A4222A020
ERU chokes
Helically wound

B82559A9153A020

Mfr. #:
Manufacturer:
EPCOS / TDK
Description:
15 UH 10%
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union