Timed contacts KZR3
-
RS Part number 85100736
"Emergency stop" and "mobile guard monitoring" functions
Safety timer function from 0,5 s to 30 s
Integrity check on control devices
1 "N/O" instantaneous safety contact with linked contacts-
6A/250 V AC
1 "N/O" timed safety contact with linked contacts -
6A/250 V AC
1 "N/C" timed safety contact with linked contacts-
6A/250 V AC
1 "N/C" timed signalling contact
Level 4 according to NF.EN 954-1
Timed contactsEmergency stopMobile guard monitoring
*** TRADUCTION MANQUANTE ***
1 power supply voltage LED
Breaking capacity (V resistive)
10
5
operations at 1500 VA resistive
5x10
5
operations at 500 VA resistive
Mechanical life (operations)
Operating temperature (°C) IEC 68
-2-14
Storage temperature (IEC 68
-2-12) (º
C)
Drop
-out / short breaks / microbreaks
Un
-30% for 10 ms every 1 s
Un
-60% for 100 ms every 1 s according to IEC 61496-1/97
Un
-100% for 10 ms every 100 ms
Un
-50% for 20 ms every 200 ms
Un
-50% for 500 ms every 5 s
Polycarbonate
Self-extinguishing-UL94 class VO
Degree of terminal protection
2 x 1,5 mm
2
multicore with ferrule
2 x 2,5 mm
2
solid conductor
Spring terminals, 2 terminals per connection point
-
rigid
wire
Spring terminals, 2 terminals per connection point
-
flexible wire
Maximum response time on emergency stop
Number of safety circuits
*** TRADUCTION MANQUANTE ***
Radiated electromagnetic field
15 kV in the air acc. to IEC 1000.4.2.
Level 3 acc. to IEC 1000.4.5
Common mode 4 kV for 230 V AC
Common mode 2 kV for 24 V DC and 24 V AC
Radio frequencies in common mode
30 V rms Level X acc. to IEC 1000.4.3
150 kHz to 80 MHz (ENV 50141) acc. to IEC 1000.4.11
European "Machinery" Directive 89/392/EEC
French decree 92/765-766-768
European "Usage" Directive 89/655/EEC
French decree 93-40 /93-41
www.crouzet.com