19
FN8251.1
May 24, 2006
Notes: (1) The device enters the Active state after any start, and remains active until: 9 clock cycles later if the Device Select Bits in the Slave
Address Byte are incorrect; 200ns after a stop ending a read operation; or t
WC
after a stop ending a write operation.
(2) The device goes into Standby: 200ns after any stop, except those that initiate a high voltage write cycle; t
WC
after a stop that initiates a high
voltage cycle; or 9 clock cycles after any start that is not followed by the correct Device Select Bits in the Slave Address Byte.
(3) V
IL
Min. and V
IH
Max. are for reference only and are not tested.
(4) At 25°C, V
CC
= 3V
(5) See ordering information for standard programming levels. For custom programmed levels, contact factory.
(6) Based on characterization data.
EQUIVALENT INPUT CIRCUIT FOR VxMON (x = 1, 2, 3)
CAPACITANCE
V
CC
Supply
V
TRIP1
(5)
V
CC
Trip Point Voltage Range 2.0 4.75 V
4.55 4.6 4.65 V X40430, X40431-A, X40434,
X40435
4.35 4.4 4.45 V X40430, X40431-B
2.85 2.9 2.95 V X40430, X40431-C
Second Supply Monitor
I
V2
V2MON Current 15 µA
V
TRIP2
(5)
V2MON Trip Point Voltage Range 1.7
0.9
4.75
3.5
V
V
x40430, X40431
x40434, X40435
2.85 2.9 2.95 V X40430, X40431-A
2.55 2.6 2.65 V X40430, X40431-B
2.15 2.2 2.25 V X40430, X40431-C
1.25 1.3 1.35 V X40434, X40435-A&B
0.95 1.0 1.05 V X40434, X40435-C
t
RPD2
(6)
V
TRIP2
to V2FAIL s
Third Supply Monitor
I
V3
V3MON Current 15 µA
V
TRIP3
(5)
V3MON Trip Point Voltage Range 1.7 4.75 V
1.65 1.7 1.75 V X40430, X40431
3.05 3.1 3.15 V X40434, X40435-A
2.85 2.9 2.95 V X40434, X40435-B&C
t
RPD3
(6)
V
TRIP3
to V3FAIL s
D.C. OPERATING CHARACTERISTICS (Continued)
(Over the recommended operating conditions unless otherwise specified)
Symbol Parameter Min Typ
(4)
Max Unit Test Conditions
+
V
REF
t
RPDX
= 5µs worst case
Output Pin
VxMON
R
C
V = 100mV
V
V
ref
Symbol Parameter Max Unit Test Conditions
C
OUT
(1)
Output Capacitance (SDA, RESET/RESET, LOWLINE,
V2FAIL
,V3FAIL, WDO)
8pF V
OUT
= 0V
C
IN
(1)
Input Capacitance (SCL, WP, MR) 6 pF V
IN
= 0V
Note: (1) This parameter is not 100% tested.
X40430, X40431, X40434, X40435
20
FN8251.1
May 24, 2006
EQUIVALENT A.C. OUTPUT LOAD CIRCUIT FOR
V
CC
= 5V
A.C. TEST CONDITIONS
SYMBOL TABLE
A.C. CHARACTERISTICS
Note: (1) Cb = total capacitance of one bus line in pF.
Input pulse levels V
CC
x 0.1 to V
CC
x 0.9
Input rise and fall times 10ns
Input and output timing levels
V
CC
x 0.5
Output load Standard output load
5V
SDA
30pF
V2MON, V3MON
4.6k
RESET
30pF
2.06k
V2FAIL
,
V
CC
4.6k
30pF
WDO
V3FAIL
Must be
steady
Will be
steady
May change
from LOW
Will change
from LOW
to HIGH
May change
from HIGH
to LOW
Will change
from HIGH
to LOW
Don’t Care:
Changes
Allowed
Changing:
State Not
Known
N/A Center Line
is High
Impedance
WAVEFORM INPUTS OUTPUTS
to HIGH
Symbol Parameter Min Max Unit
f
SCL
SCL Clock Frequency 400 kHz
t
IN
Pulse width Suppression Time at inputs 50 ns
t
AA
SCL LOW to SDA Data Out Valid 0.1 0.9 µs
t
BUF
Time the bus free before start of new transmission 1.3 µs
t
LOW
Clock LOW Time 1.3 µs
t
HIGH
Clock HIGH Time 0.6 µs
t
SU:STA
Start Condition Setup Time 0.6 µs
t
HD:STA
Start Condition Hold Time 0.6 µs
t
SU:DAT
Data In Setup Time 100 ns
t
HD:DAT
Data In Hold Time 0 µs
t
SU:STO
Stop Condition Setup Time 0.6 µs
t
DH
Data Output Hold Time 50 ns
t
R
SDA and SCL Rise Time 20 +.1Cb
(1)
300 ns
t
F
SDA and SCL Fall Time 20 +.1Cb
(1)
300 ns
t
SU:WP
WP Setup Time 0.6 µs
t
HD:WP
WP Hold Time 0 µs
Cb Capacitive load for each bus line 400 pF
X40430, X40431, X40434, X40435
21
FN8251.1
May 24, 2006
TIMING DIAGRAMS
Bus Timing
WP Pin Timing
Write Cycle Timing
Nonvolatile Write Cycle Timing
Note: (1) t
WC
is the time from a valid stop condition at the end of a write sequence to the end of the self-timed internal nonvolatile write cycle. It is
the minimum cycle time to be allowed for any nonvolatile write by the user, unless Acknowledge Polling is used.
t
SU:STO
t
HIGH
t
SU:STA
t
HD:STA
t
HD:DAT
t
SU:DAT
SCL
SDA IN
SDA OUT
t
F
t
LOW
t
BUF
t
R
t
DH
t
AA
t
HD:WP
SCL
SDA IN
WP
t
SU:WP
Clk 1 Clk 9
Slave Address Byte
START
SCL
SDA
t
WC
8
th
Bit of Last Byte
ACK
Stop
Condition
Start
Condition
Symbol Parameter Min Typ Max Unit
t
WC
(1)
Write Cycle Time 5 10 ms
X40430, X40431, X40434, X40435

X40431S14-B

Mfr. #:
Manufacturer:
Renesas / Intersil
Description:
IC VOLT MON TRPL EEPROM 14-SOIC
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: