THD< 20% when output loading≧75% at 115VAC/230VAC input and output loading≧75% at 277VAC input
TOTAL HARMONIC DISTORTION
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC
SPECIFICATION
MODEL PLN-100-12 PLN-100-15 PLN-100-20 PLN-100-24 PLN-100-27 PLN-100-36 PLN-100-48
DC VOLTAGE
RATED CURRENT Note.5
RATED POWER Note.5
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS Note.7
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT
OVER VOLTAGE
OVER TEMPERATURE
12V 15V 20V 24V 27V 36V 48V
5A 5A 4.8A 4A 3.55A 2.65A 2A
60W 75W 96W 96W 95.85W 95.4W 96W
150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p
±3.0%
±1.0%
±2.0%
500ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load
60ms/230VAC 16ms/115VAC at full load
90 ~ 295VAC 127 ~ 417VDC
47 ~ 63Hz
PF>0.95/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
±3.0% ±3.0% ±3.0% ±3.0% ±2.0% ±2.0%
13 ~ 16V 16.5 ~ 20V 22 ~ 27V 27 ~ 34V 30 ~ 36V 39 ~ 48V 52 ~ 64V
COLD START 40A(twidth=1030 s measured at 50% Ipeak) at 230VACμ
<0.75mA / 240VAC
95 ~ 102%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
-30 ~ +50℃ (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80℃, 10 ~ 95% RH
±0.03%/℃ (0 ~ 50℃)
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
303.1Khrs min. MIL-HDBK-217F (25℃)
200*70.5*35mm (L*W*H)
0.52Kg; 20pcs/12.5Kg/0.9CUFT
Protection type : Shut down and latch off o/p voltage, re-power on to recover
100W Single Output Switching Power Supply
‧UniversalACinput/Fullrange(upto295VAC)
‧Highefficiencyupto88.5%
‧Protections:Shortcircuit/Overcurrent/Overvoltage/Overtemperature
‧Coolingbyfreeairconvection
‧Built-inactivePFCfunction
‧FullyisolatedplasticcasewithIP64level
‧PassLPS
‧Class2powerunit
‧100%fullloadburn-intest
‧Highreliability
‧SuitableforLEDlightingandmovingsignapplications
‧Suitablefordry/damplocations
‧Compliancetoworldwidesafetyregulationsforlighting
‧2yearswarranty
■Features:
PLN-100 series
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, re-power on to recover
Compliance to EN55015, EN55032 (CISPR32) Class B, EN61000-3-2 Class C (>75% load) ; EN61000-3-3;GB17743 and GB17625.1,EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A;EAC TP TC 020
IP64
..
M M
110
LPS
SELV
9 ~ 12V 11.25 ~ 15V 15 ~ 20V 18 ~ 24V 20.25 ~ 27V 27 ~ 36V 36 ~ 48V
CONSTANT CURRENT REGION Note.6
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
VOLTAGE ADJ. RANGE (SVR1)
CURRENT ADJ. RANGE(SVR2)
10.2 ~ 12V
3.75 ~ 5A
12.8 ~ 15V
3.75 ~ 5A
17 ~ 20V
3.6 ~ 4.8A
20.4 ~ 24V
3 ~ 4A
23 ~ 27V
2.6 ~ 3.55A
30.6 ~ 36V
2 ~ 2.65A
40.8 ~ 48V
1.5 ~ 2A
EMC IMMUNITY
EMC EMISSION
83% 85% 88.5% 88.5% 88% 88% 88.5%
12V:0.8A/115VAC 0.4A/230VAC 0.3A/277VAC 15V:0.9A/115VAC 0.45A/230VAC 0.35A/277VAC
20V ~ 48V:1.1A/115VAC 0.55A/230VAC 0.45A/277VAC
1.AllparametersNOTspeciallymentionedaremeasuredat230VACinput,ratedloadand25℃ofambienttemperature.
2.Ripple&noisearemeasuredat20MHzofbandwidthbyusinga12"twistedpair-wireterminatedwitha0.1uf&47ufparallelcapacitor.
3.Tolerance:includessetuptolerance,lineregulationandloadregulation.
4.Deratingmaybeneededunderlowinputvoltage.Pleasecheckthestaticcharacteristicsformoredetails.
5.Thisisthemaximumpossibleoutputcurrentandpower.Overloadprotectionmaybeactivatedslightlybelowthisleveltocomplywiththerequirement
ofUL1310class2.
6.Pleasereferto"DRIVINGMETHODSOFLEDMODULE".
7.SafetyandEMCdesignrefertoEN60598-1,subject8750(UL),CNS15233,GB7000.1,FCCpart18.
8.Thepowersupplyisconsideredasacomponentthatwillbeoperatedincombinationwithfinalequipment.SinceEMCperformancewillbeaffectedbythe
completeinstallation,thefinalequipmentmanufacturersmustre-qualifyEMCDirectiveonthecompleteinstallationagain.
9.TofulfillrequirementsofthelatestErPregulationforlightingfixtures,thisLEDpowersupplycanonlybeusedbehindaswitchwithoutpermanently
connectedtothemains.
10.Theambienttemperaturederatingof3.5℃/1000mwithfanlessmodelsandof5℃/1000mwithfanmodelsforoperatingaltitudehigherthan2000m(6500ft).
File Name:PLN-100-SPEC 2018-06-07
UL879, UL1310, UL8750, CSA C22.2 No. 207-M89, TUV EN61347-1, EN61347-2-13 independent, TUV EN60950-1,CAN/CSA C22.2 No.223-M91(except for 48V),
CAN/CSA C22.2 No. 250.13-12, EAC TP TC 004,GB19510.1,GB19510.14,IP64, J61347-1, J61347-2-13 approved ; design refer to UL60950.
(exceptfor48V)forUL1310
(allmodels)forUL8750andUL879
(for48Vonly)
(CCCoptional)