SPECIFICATION
MODEL
APV-8-5
APV-8-12
APV-8-24
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
Note.8
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVER LOAD
OVER VOLTAGE
5V
12V
24V
1.4A
0.67A
0.34A
0 ~ 1.4A
0 ~ 0.67A
0 ~ 0.34A
7W
8.04W
8.16W
250mVp-p
250mVp-p
300mVp-p
±5.0%
±1.0%
±2.0%
500ms, 30ms / 230VAC 1500ms,30ms / 115VAC at full load
90 ~ 264VAC 127 ~ 370VDC ( )
Note.6
47 ~ 63Hz
74%
80%
81%
5.75 ~ 6.75V
13.8 ~ 16V
27.6 ~ 32.4V
0.15A/230VAC 0.3A/115VAC
COLD START 70A(twidth=120 s measured at 50% Ipeak) at 230VACμ
0.25mA / 240VAC
-30 ~ +70 (Refer to "Derating Curve")℃
20 ~ 90% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 45 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be
affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. When applying DC voltage for input, please connect the brown input wire to the positive side whereas blue input wire to the negative side.
7. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
8.
The model certified for CCC(GB19510.14, GB19510.1, GB17743 and GB17625.1) is an optional model . Please contact MEAN WELL for details.
Protection type : Shut off o/p voltage, clamping by zener diode
8W Single Output Switching Power Supply
APV-8 series
RIPPLE & NOISE
(max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
20ms/230VAC at full load
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH℃
EMC IMMUNITY
EMC EMISSION
60*30*23.5mm(L*W*H)
1631.5K hrs min. MIL-HDBK-217F (25 )℃
Above 105% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
Compliance to EN55032,EN61000-3-2 Class A,EN61000-3-3, EAC TP TC 020
Compliance to EN55024,EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), criteria A, EAC TP TC 020
UL8750,CSA C22.2 No.250.0-08,BIS IS15885(except for 5V), EAC TP TC 004 approved;
design refer to EN60950-1,EN61347-1,EN61347-2-13
0.05Kg;144pcs/7.6Kg/0.75CUFT
File Name:APV-8E-SPEC 2018-01-05