2
Technical Data 10578
Effective December 2016
CL0608
Multi-phase power inductors
www.eaton.com/electronics
Product specifications
Part Number
5
Inductor
Phases
OCL
1
(nH) ±20%
FLL
2
(nH) minimum
I
sat
1
2
(A)
DCR (mΩ)
±10%
@ 20 °C
SCL
3
(nH) ±20%
I
sat
2
4
(A)
CL0608- 2- 100TR-R 2 380 300 15 0.89 100 38
1. Open Circuit Inductance (OCL) Test Parameters: 1.0 MHz, 0.1 V
rms
, 0.0 Adc, +25 °C
2. Full Load Inductance (FLL) Test Parameters: 1.0 MHz, 0.1 V
rms
, I
sat
1, +25 °C
3. Short Circuit Inductance (SCL) Test Parameters: 1.0 MHz, 0.1 V
rms
, 0.0 Adc, +25 °C
CL0608-2-100TR-R short (1 & 4), measure (2 & 3), and divide by 2.
4. I
sat
2: Peak current where SCL drops approximately 20% @ +25 °C
8. Part Number Definition: CL0608-x-100TR-R
CL0608 = Product code and size
x = Number of phases
100 = Inductance value per phase in nH
TR = Tape and reel packaging
-R suffix = RoHS compliant
Note: This device is licensed for use only when incorporated within a voltage regulator
employing power regulating devices manufactured by Maxim Integrated Devices, Inc.
No license is granted expressly or by implication to use this device with power
regulating devices manufactured by any company other than Maxim.
Dimensions (mm)
Part marking: CL0608-x-100TR-R (x = number of phases), xxxx = lot code
Tolerances are ±0.25 millimeters unless stated otherwise
All soldering surfaces to be coplanar within 0.13 millimeters
PCB tolerances are ±0.1 millimeters unless stated otherwise
DCR measured from point “a” to point “b”
Do not route traces or vias underneath the inductor
Packaging information (mm)
Supplied in tape and reel packaging , 500 parts per 13” diameter reel
Drawing not to scale