SCT45

811-800-526-2324 • www.us.tdk-lambda.com/lp/ Disclaimer: us.tdk-lambda.com/lp/legal.htm
SC40/60 Series
Features
Low Cost
Single and Multiple Outputs
Wide Range AC Input
Low pro le
Global Safety Agency Compliance
Meets EN61000-4 (-2 to -6)
Industry standard footprint
40-60W, 3 x 5” AC-DC Power Supplies
Model SCS40 SCT4x SCS60 SCD60 SCT6x
Output Power Convection W 40 60
Output Power Forced Air W 55 -
Main Output Adjustment V -5, +10% O/P 1 only -5, +10%
Line and Load Regulation % Output 1: ±2%, Output 2: ±5% (±7% on 24V models), Output 3: ±5%
Hold Up Time (typical) ms 20 20
Size (1) in 3 x 5 x 1” 3 x 5 x 1.34”
AC Input - 85-265 VAC, 47-63 Hz
Ef ciency % Typically 70% full load at nominal AC Line
Inrush Current Limiting A 36A typical @230VAC cold start
Surge Immunity - EN61000-4 (-2 through -6) level 3
EMI - FCC Class B, EN55022 B
Cross Regulation % ± 2% on output 1, ±5% on outputs 2 & 3 (multiple outputs only)
Ripple and Noise % 1% peak to peak
Overcurrent Protection - Short circuit protection, automatic recovery
Overvoltage Protection - Output 1 only, <135%
Cooling - When speci ed with forced air cooling, ow is 300 LFM (1.5m/s)
Operating Temp. Range (2) - 0 to +70°C (Derate linearly to 50% load from 50-70°C)
Storage Temperature °C -20 to +85°C
Safety Agency Approval - UL60950-1, CSA60950-1, IEC/EN60950-1, CE Mark
Warranty yr 1 year
Speci cations
(1) Height is speci ed as maximum component height
Note: See Installation Manual for full details, test methods of parameters and application notes
(2) -40°C startup, contact factory for details.
Key Market Segments & Applications
821-800-526-2324 • www.us.tdk-lambda.com/lp/
Revision B5: Apr 2015
SC40/60 Series
For Additional Information, please visit
us.tdk-lambda.com/lp/products/sc-series.htm
Outline Drawing
ZP 20 to 60W 2” x 4”, 1-3 outputs
NV175 175W 3” x 5”, 1-5 outputs
ZWS 5 to 240W single output, universal input
VSB, VSC, VSP 10 to 150W single output, 115VAC input
SCS120PW 120W 3” x 5” single output
CSS150 150W 3” x 5” single output
Other AC-DC Products
O/P Min Convec. Forced Peak
Model (V) Load(A) (A) Air(A) Load(A)**
Single Output SCS4024 V1 24.0 - 1.6 2.3 2.5
SCS4048 V1 48.0 - 0.9 1.2 1.3
SCS6012 V1 12.0 - 5.0 6.7 7.5
SCS6024 V1 24.0 - 2.5 3.3 3.8
SCS6028 V1 28.0 - 2.1 2.9 3.2
SCS6048 V1 48.0 - 1.3 1.7 1.9
Dual Output SCD601515 V1 15.0 0.2 2.2 2.9 -
V2 -15.0 0.2 1.8 2.4 -
Triple Output SCT42 V1 5.0 0.4 4.0 5.0 7.0
V2 12.0 0.2 2.0 2.5 4.0
V3 -12.0 - 0.5 0.7 1.0
SCT45 V1 5.0 0.4 4.0 5.0 7.0
V2 15.0 0.2 2.0 2.5 3.0
V3 -15.0 - 0.5 0.7 1.0
SCT48/R* V1 5.0 0.4 4.0 5.0 6.0
V2 24.0 0.1 1.0 1.5 2.0
V3 -5.0 - 0.5 0.7 1.0
SCT62 V1 5.0 0.7 7.0 - 10.0
V2 12.0 0.3 3.0 - 6.0
V3 -12.0 - 0.7 - 1.5
SCT63 V1 5.0 0.7 7.0 - 10.0
V2 15.0 0.3 2.8 - 4.0
V3 -15.0 - 0.7 - 1.5
SCT65 V1 5.0 0.7 7.0 - 10.0
V2 24.0 0.1 1.5 - 3.0
V3 12.0 - 0.7 - 1.5
Options
Model Selector Notes:
* /R = Remote Sense. Leave unconnected when not used.
** <30s, 10% duty cycle, average power must not exceed maximum ratings.

SCT45

Mfr. #:
Manufacturer:
TDK-Lambda
Description:
Switching Power Supplies 40W 5V 15V 0.4A
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS