811-800-526-2324 • www.us.tdk-lambda.com/lp/ Disclaimer: us.tdk-lambda.com/lp/legal.htm
SC40/60 Series
Features
Low Cost
Single and Multiple Outputs
Wide Range AC Input
Low profi le
Global Safety Agency Compliance
Meets EN61000-4 (-2 to -6)
Industry standard footprint
40-60W, 3 x 5” AC-DC Power Supplies
Model SCS40 SCT4x SCS60 SCD60 SCT6x
Output Power Convection W 40 60
Output Power Forced Air W 55 -
Main Output Adjustment V -5, +10% O/P 1 only -5, +10%
Line and Load Regulation % Output 1: ±2%, Output 2: ±5% (±7% on 24V models), Output 3: ±5%
Hold Up Time (typical) ms 20 20
Size (1) in 3 x 5 x 1” 3 x 5 x 1.34”
AC Input - 85-265 VAC, 47-63 Hz
Effi ciency % Typically 70% full load at nominal AC Line
Inrush Current Limiting A 36A typical @230VAC cold start
Surge Immunity - EN61000-4 (-2 through -6) level 3
EMI - FCC Class B, EN55022 B
Cross Regulation % ± 2% on output 1, ±5% on outputs 2 & 3 (multiple outputs only)
Ripple and Noise % 1% peak to peak
Overcurrent Protection - Short circuit protection, automatic recovery
Overvoltage Protection - Output 1 only, <135%
Cooling - When specifi ed with forced air cooling, fl ow is 300 LFM (1.5m/s)
Operating Temp. Range (2) - 0 to +70°C (Derate linearly to 50% load from 50-70°C)
Storage Temperature °C -20 to +85°C
Safety Agency Approval - UL60950-1, CSA60950-1, IEC/EN60950-1, CE Mark
Warranty yr 1 year
Specifi cations
(1) Height is specifi ed as maximum component height
Note: See Installation Manual for full details, test methods of parameters and application notes
(2) -40°C startup, contact factory for details.
Key Market Segments & Applications