Electronic device circuit breaker-ECP-E3 2A-0912042
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Electronic device circuit breaker, Number of positions:1, Connection method:Screw connection, Width:12.5 mm,
Fuse type:Electronic, Fuse type:Automatic device, Mounting type:On base element, Color:black
The figure shows the ECP-E3 1A
version
Why buy this product
Includes the advantages of current limitation
Output voltage of switched-mode power supply unit remains stable
Sufficient supply of all error-free load circuits
Application - all aspects of the switched-mode power supply unit
In addition, the ECP-E2 can be controlled remotely by the control input (12), e.g., by means of a PLC
Responds faster than switched-mode power supply unit to overload and short circuit
Key Commercial Data
Packing unit 1 STK
Custom tariff number 85362010
Country of origin Germany
Technical data
General
Installation instructions
When mounted in rows without convection cooling, the nominal device
current should only be led to a maximum of 80% due to the thermal effect
during continuous operation (100% operating factor).
Special precautionary measures must be taken in systems or machines, to
prevent components from restarting (e.g., use of a safety PLC).
Parallel connection of multiple circuit breakers is not permitted.
Mounting type On base element
Color black
https://www.phoenixcontact.com/us/products/0912042
08/01/2016Page2/4
Electronic device circuit breaker-ECP-E3 2A-0912042
Technical data
General
Number of positions 1
Overvoltage category II
Insulating material PA66/6
Flammability rating according to UL 94 V0
Electrical data
Fuse Electronic
Fuse type Automatic device
Rated surge voltage 0.5 kV
Operating voltage 24 V DC
24 V DC ()
18 V DC ... 32 V DC
Nominal current I
N
2 A
Required backup fuse not required, integrated failsafe element
Dielectric strength max. 32 V DC (Load circuit)
Degree of pollution 2
Overvoltage category II
Insulating material group I
Switching capacity I
CN
Active current limitation
Closed-circuit current range I0 typ. 25 mA ±5 mA (When switched on)
Dimensions
Height 60 mm
Width 12.5 mm
Depth 70 mm
Height NS 35/7,5 144 mm
Height NS 35/15 151.5 mm
Complete module height 115 mm
Complete module width 38 mm
Complete module depth 112.5 mm
Ambient conditions
Degree of protection IP30 (Actuation area)
Ambient temperature (operation) 0 °C ... 50 °C (non-condensing)
Connection data
Connection method Screw connection
Standards and Regulations
Standards/specifications UL 2367
https://www.phoenixcontact.com/us/products/0912042
08/01/2016Page3/4
Electronic device circuit breaker-ECP-E3 2A-0912042
Technical data
Standards and Regulations
UL 508
CSA 22.2 No. 14
Drawings
Block diagram
2
12
14
13
11
1
Control Unit
I<
LINE (+)
SO
Reset
SC
LOAD (+)
GND (-)
On/Off
Classifications
eCl@ss
eCl@ss 4.0 27141116
eCl@ss 4.1 27141116
eCl@ss 5.0 27141116
eCl@ss 5.1 27141116
eCl@ss 6.0 27141116
eCl@ss 7.0 27141116
eCl@ss 8.0 27141116
eCl@ss 9.0 27141116
ETIM
ETIM 2.0 EC000899
ETIM 3.0 EC000899
ETIM 4.0 EC000899
ETIM 5.0 EC000899
UNSPSC
UNSPSC 6.01 30211812
UNSPSC 7.0901 39121411
UNSPSC 11 39121411
UNSPSC 12.01 39121411
UNSPSC 13.2 39121411

0912042

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
Terminal Block Tools & Accessories ECP-E3 2A
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet