Additional tests and test conditions
For type C1172:
Enhanced test condition to K.20
power induction
600 V
AC
, R = 600 Ω, t = 0.5 s, without GDT, criteria A
(no damage, function must be fulfilled)
Enhanced test condition to K.20
single port, lightning
V
c(max)
= 2500 V, t = 1.2/50 µs, R = 2 Ω, without GDT,
criteria A (no damage, function must be fulfilled)
Number of cycles: 500
For type C1173:
Enhanced test condition to K.20
power induction
600 V
AC
, R = 600 Ω, t = 0.5 s, without GDT, criteria A
(no damage, function must be fulfilled)
Enhanced test condition to K.20
single port, lightning
V
c(max)
= 4 kV, t = 10/700 µs, R = 40 Ω, without GDT,
criteria A (no damage, function must be fulfilled)
For type C1183:
GR1089
Second level intra building AC
power fault
120 V
AC
(50 Hz), short circuit current 25 A, t = 15 min,
criteria A (no damage, function must be fulfilled)
Enhanced test condition to K.20
power induction
600 V
AC
, R = 600 Ω, t = 1 s, without GDT, criteria A
(no damage, function must be fulfilled)
Enhanced test condition to K.20
single port, lightning
V
c(max)
= 4 kV, t = 10/700 µs, R = 40 Ω, without GDT,
criteria A (no damage, function must be fulfilled)
For type C1184:
Enhanced test condition to K.20
power induction
600 V
AC
, R = 600 Ω, t = 0.5 s, without GDT, criteria A
(no damage, function must be fulfilled)
Enhanced test condition to K.20
power contact
230 V
AC
, t = 15 min., R = 10 ... 1000 Ω, criteria A
(no damage, function must be fulfilled)
For type U1154:
GR1089
Second level intra building AC
power fault
120 V
AC
(50 Hz), short circuit current 25 A, t = 15 min,
criteria A (no damage, function must be fulfilled)
Enhanced test condition to GR1089
first level intra building lightning
surge for multi-pair ports
V
c(max)
= ±2.25 kV (each polarity 1 application), t = 2/10 µs,
R
G
= 2 Ω, R = 12 Ω, criteria A
(no damage, function must be fulfilled)
Overcurrent protection for telecom
Leaded disks