MKP1848C DC-Link
www.vishay.com
Vishay Roederstein
Revision: 21-Mar-16
16
Document Number: 26015
For technical questions, contact: dc-film@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
INSPECTION REQUIREMENTS
SUB-CLAUSE NUMBER AND TEST CONDITIONS PERFORMANCE REQUIREMENTS
ROUTINE TEST - FINAL INSPECTION
5.14.2-1
External inspection, visual examination
Legible marking as specified
5.14.2-2
Dimensions
See specification drawing
5.3-1
Capacitance
1 kHz at room temperature See specific reference data
5.3-2
tan
1 kHz at room temperature
10 kHz at room temperature
See specific reference data
5.5.1-2
Voltage test between terminals
1.5 x U
NDC
at T
amb
Duration: 10 s
No visible damage or puncture
No flashover
5.7
Insulation resistance
U
NDC
500 V measuring voltage 100 V at
room temperature
U
NDC
> 500 V measuring voltage 500 V at
room temperature
Duration: 1 min
See specific reference data
TYPE TESTS
5.14.2
External inspection
Check for finish, marking and overall
dimensions
Legible marking and finish as specified
Dimensions: see specification drawing
5.14.0
Initial measurements
Capacitance at 1 kHz
tan at 10 kHz
5.14.1-1/4 Tensile Ua1
Robustness of terminations
IEC 60068-2-21
Wire diameter Section modulus Load
0.8 mm 0.5 mm
2
10 N
1.25 mm 1.2 mm
2
20 N
Duration: 10 s ± 1 s
Bending, Ub method 1
Wire diameter Section modulus Load
0.8 mm 0.05 mm
2
10 N
1.25 mm 0.019 mm
2
20 N
4 x 90°, duration: 2 s to 3 s/bend
5.14.1-6
Resistance to soldering heat
IEC 60068-2-20
No pre-drying, method 1A
Solder bath: 260 °C ± 5 °C
Duration: 10 s ± 1 s
5.14.4
Final measurements
Capacitance
tan
|C/C| 0.5 %
Increase of tan 0.0050
compared to the values measured in 5.14.0
5.14.0
Initial measurements
Capacitance at 1 kHz
tan at 10 kHz
5.14.3-1
Vibration
IEC 60068-2-6
10 Hz to 55 Hz; amplitude ± 0.35 mm or
acceleration 98 m/s
2
Test duration: 10 frequency cycles
3 axes offset from each other by 90°
1 octave/min
Visual examination No visible damage
5.14.3-2
Shock or impact
IEC 60068-2-6
Pulse shape: half sine
Acceleration: 490 m/s
2
Duration of pulse: 11 ms
Visual examination No visible damage
5.14.4
Final measurements
Capacitance
tan
|C/C| 0.5 %
Increase of tan 0.0050
compared to the values measured in 5.14.0
MKP1848C DC-Link
www.vishay.com
Vishay Roederstein
Revision: 21-Mar-16
17
Document Number: 26015
For technical questions, contact: dc-film@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
5.5.3-1
Initial measurements
Capacitance at 1 kHz
tan at 10 kHz
R insulation
5.5.3-2
Voltage test between terminals
1.5 x U
NDC
at T
amb
Duration: 60 s
5.5.3-3
Final measurements
Capacitance
tan 
R insulation
|C/C| 0.5 %
Increase of tan 0.0050
R insulation 50 % of specified values
5.9-1
Initial measurements
Capacitance at 1 kHz
tan at 10 kHz
5.9-2
Surge discharge test
1.1 x U
NDC
Number of discharges: 5
Time lapse: every 2 min (10 min total)
5.9-2
Voltage test between terminals
Within 5 min after the surge
discharge test
Duration: 60 s
1.5 x U
NDC
at T
amb
5.9-3
Final measurements
Capacitance
tan at 10 kHz
|C/C| 1.0 %
tan 1.2 x initial tan + 0.0001
compared to the values measured in 5.9-1
5.11-1
Initial measurements
Capacitance at 1 kHz
tan at 10 kHz
5.11-2
Self healing test
1.5 x U
NDC
Duration: 10 s
Number of clearings 5
Clearing = voltage drop of 5 %
increase the voltage at 100 V/s till
5 clearings occur
with a max. of 2.5 x U
NDC
for a duration of 10 s
5.11-3
Final measurements
Capacitance
tan
|C/C| 0.5 %
tan 1.2 x initial tan + 0.0001
compared to the values measured in 5.11-1
5.13-0
Initial measurements
Capacitance at 1 kHz
tan at 10 kHz
5.13-1
Change of temperature according to
IEC 60682-2-14
Test Nb
T
max.
= 85 °C
T
min.
= -55 °C
Transition time: 1 h, equivalent to 1 °C/
min. 5 cycles
5.13-2
Damp heat steady state according to
IEC 60682-2-78
Test Ca
T
max.
= 40 °C + 2 °C
RH = 93 % ± 3 %
Duration: 56 days
5.5.3-2
Voltage test between terminals
1.5 x U
NDC
at ambient temperature
Duration: 60 s
5.13-3
Final measurements
Visual examination No puncturing or flashover
Self healing punctures are permitted
Capacitance
tan at 1 V
RMS
10 kHz
|C/C| 2.0 %
Increase of tan 0.0150
compared to the values measured in 5.13-0
INSPECTION REQUIREMENTS
SUB-CLAUSE NUMBER AND TEST CONDITIONS PERFORMANCE REQUIREMENTS
MKP1848C DC-Link
www.vishay.com
Vishay Roederstein
Revision: 21-Mar-16
18
Document Number: 26015
For technical questions, contact: dc-film@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
5.10.0
Initial measurements
Capacitance at 1 kHz
tan at 10 kHz
5.10-1
Thermal stability test under overload
conditions
Natural cooling T
amb
± 5 °C
1.21 x P
max.
= (U
2
/2) x W
2
x C x tan =
1.21 x (I
2
max.
/W
2
x C) x tan 
with W
2
= 2 x p x f
2
for I
max.
(see specific reference data)
f
2
= 10 kHz
Duration: 48 h
5.10-2
Final measurements
Measure the temperature every 1.5 h
during the last 6 h
Temperature rise 1 °C
|C/C| 2.0 %
Increase of tan 1.2 x initial + 0.0150
5.12
Resonance frequency measurement
Impedance analyser at T
amb
< 0.9 times the value as specified in typical
curve “Resonant frequency” of this
specification
5.15-0
Initial measurements
Capacitance at 1 kHz
tan at 10 kHz
5.15-1
Endurance test between terminals
Sequence:
1.3 x U
NDC
at 85 °C
1.3 x U
OPDC
at 105 °C
Duration: 500 h
1000 x discharge
at 1.3 x I
peak
(maximum respective peak
current in continuous operation)
1.3 x U
NDC
at 85 °C
1.3 x U
OPDC
at 105 °C
Duration: 500 h
5.15-2
Final measurement
Capacitance
tan
|C/C| 3.0 %
Increase of tan 0.0150
compared to the values measured in 5.15-0
5.16.3-0A
Initial measurements
Capacitance at 1 kHz
5.16.3-1A
Destruction test sequence for non segment
film
T
max.
= 85 °C
Product enveloped with cheese cloth
High DC voltage test 3 x U
NDC
or DC voltage
until repetitive product healings occur
Duration = 15 min
Audible healings or check healings with
oscilloscope
High AC voltage test AC RMS voltage = U
NDC
/2 2
with minimum of 250 V
AC
Duration = 5 min
Repeat destruction sequence 3 x
5.16.3-2A
Final measurements
Visual examination No puncturing, flashover or burning of the
cheese cloth
Self healing punctures are permitted
INSPECTION REQUIREMENTS
SUB-CLAUSE NUMBER AND TEST CONDITIONS PERFORMANCE REQUIREMENTS

MKP1848C65560JY5

Mfr. #:
Manufacturer:
Description:
Film Capacitors MKP , 55 uF , 5% , 600Vdc, pitch 52,5 , 4 pins
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: