Circuit diagram
Technical data and measuring conditions
Rated voltage V
R
250 V AC (50/60 Hz) / 250 V DC
Rated current I
R
Referred to 40 °C rated temperature
Test voltage V
test
1414 V DC, 2 s (line/line)
2700 V DC, 2 s (lines/case)
Climatic category (IEC 60068-1) 25/085/21 (25 °C/+85 °C/21 days damp heat test)
Approvals IEC 60939, UL 1283, CSA C22.2 No.8
Characteristics and ordering codes
I
R
A
C
R
X2
µF
C
R
Y2
pF
L
R
mH
I
LK
mA
Approx.
weight
g
Ordering code
Approvals
× = Approval granted
V
R
= 250 V AC/DC
3 2 × 0.47 2 × 4700 4 × 4.7 0.369 210 B84113C0000A030 × × ×
3 2 × 0.47 2 × 4700 4 × 4.7 0.369 210 B84113C0000B030 × × ×
6 2 × 0.47 2 × 4700 4 × 4.7 0.369 510 B84113C0000A060 × × ×
6 2 × 0.47 2 × 4700 4 × 4.7 0.369 510 B84113C0000B060 × × ×
10 2 × 0.47 2 × 4700 4 × 3.6 0.369 690 B84113C0000A110 × × ×
10 2 × 0.47 2 × 4700 4 × 3.6 0.369 690 B84113C0000B110 × × ×
2-line filters B84113C
SIFI-C for very high insertion loss
Page 3 of 11Please read Cautions and warnings and