Data Sheet ADuM4151/ADuM4152/ADuM4153
REGULATORY INFORMATION
The ADuM4151/ADuM4152/ADuM4153 are approved by the organizations listed in Table 14. See Table 19 and the Insulation Lifetime
section for the recommended maximum working voltages for specific cross isolation waveforms and insulation levels.
Table 14.
UL CSA VDE
Recognized Under UL 1577
Component Recognition Program
1
Approved under CSA Component Acceptance
Notice 5A
Certified according to DIN V VDE V 0884-10
(VDE V 0884-10):2006-12
2
5000 V rms Single Protection Basic insulation per CSA 60950-1-07+A1+A2
and IEC 60950-12nd Ed+A1+A2., 800 V rms
(1131 V peak) maximum working voltage
3
Reinforced insulation, 849 V peak
Reinforced Insulation per CSA 60950-1-
07+A1+A2 and IEC 60950-1 2
nd
Ed.+A1+A2,
400 V rms (565 V peak) maximum working
voltage
Reinforced insulation (2MOPP) per IEC 60601-1
Ed.3.1, 250 V rms (353 V peak) maximum
working
File E214100 File 205078 File 2471900-4880-0001
1
In accordance with UL 1577, each model is proof tested by applying an insulation test voltage ≥6000 V rms for 1 second (current leakage detection limit = 10 µA).
2
In accordance with DIN V VDE V 0884-10, each model is proof tested by applying an insulation test voltage ≥ 1590 V peak for 1 second (partial discharge detection limit = 5 pC).
The asterisk (*) marked on the component designates DIN V VDE V 0884-10
approval.
3
Use at working voltages above 400 V
AC
RMS
shortens lifetime of the isolator significantly. See Table 19 for recommended maximum working voltages under ac and dc conditions.
INSULATION AND SAFETY RELATED SPECIFICATIONS
Table 15.
Parameter Symbol Value Unit Test Conditions/Comments
Rated Dielectric Insulation Voltage 5000 V rms 1-minute duration
Minimum External Air Gap (Clearance) L(I01) 8.3 mm min Measured from input terminals to output terminals,
shortest distance through air
Minimum External Tracking (Creepage) L(I02) 8.3 mm min Measured from input terminals to output terminals,
shortest distance path along body
Minimum Internal Gap (Internal Clearance) 0.017 mm min Insulation distance through insulation
Tracking Resistance (Comparative Tracking Index) CTI >400 V DIN IEC 112/VDE 0303, Part 1
Material group (DIN VDE 0110, 1/89, Table 1)