Users should evaluate the suitability of this product for their application. Specications are subject to change without notice.
Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specication, without notication to Buyer.
1/ COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE
ADDED TO THE PART NUMBER. AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
Page 1 of 2
TE Connectivity, TE connectivity (logo), TE (logo), and Raychem are trademarks.
Raychem Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-227-8816
Fax: 1-650-361-6297
DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL.
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
© 2005-2011 Tyco Electronics Corporation,. All rights reserved.
SPECIFICATION CONTROL DRAWING
FLTW+0319
GENERAL PURPOSE HOOKUP WIRE, MODIFIED POLYESTER-INSULATED, 600 VOLT 4-18-11 L
The complete requirements for procuring the wire described herein shall consist of this document and the issue in effect of
Raychem Specication WCD 3106, UL Subject 758, Style 10208, File E303150 and carries UL labels to this effect.
TITLE
Date Revision
CONSTRUCTION DETAILS
PART NUMBER
1/
WIRE
SIZE
(AWG)
CONDUCTOR
STRANDING
(number x AWG)
NOMINAL
CONDUCTOR
DIAMETER
(in.) (mm)
FINISHED WIRE
MAXIMUM
RESISTANCE
AT 20°C
(ohms/1000 ft.)
(ohms/km)
DIAMETER
(in.) (mm)
NOMINAL
WEIGHT
(lbs/1000 ft.)
(kg/km)
MINIMUM NOMINAL MAXIMUM
FLTWB0319-20-* 20 7 x 28 .038 (.965) 10.6 (34.8) .054 (1.37) .056 (1.42) .058 (1.47) 4.2 (6.25)
FLTWC0319-24-* 24 19 x 36 .024 (.610) 26.7 (87.6) .036 (.914) .038 (.965) .040 (1.02) 2.2 (3.27)
FLTWC0319-22-* 22 19 x 34 .030 (.762) 16.9 (55.4) .044 (1.12) .046 (1.17) .048 (1.22) 2.8 (4.17)
FLTWC0319-20-* 20 19 x 32 .038 (.965) 10.6 (34.8) .054 (1.37) .056 (1.42) .058 (1.47) 4.4 (6.55)
FLTWC0319-18-* 18 19 x 30 .047 (1.19) 6.66 (21.9) .063 (1.60) .065 (1.65) .067 (1.70) 6.3 (9.38)
FLTWC0319-16-* 16 19 x 29 .059 (1.50) 4.82 (15.8) .076 (1.93) .079 (2.01) .082 (2.08) 8.6 (12.8)
FLTWC0319-14-* 14 19 x 27 .072 (1.83) 3.05 (10.0) .092
(2.34) .096 (2.44) .100 (2.54) 13.8 (20.5)
FLTWD0319-12-* 12 37 x 28 .090 (2.29) 2.01 (6.59) .110 (2.79) .114 (2.90) .118 (3.00) 22.9 (34.1)
FLTWD0319-10-* 10 37 x 25 .113 (2.87) 1.26 (4.13) .133 (3.38) .137 (3.48) .141 (3.58) 35.1 (52.2)
CONDUCTOR - BARE COPPER
INSULATION - FLAME RETARDED,
MODIFIED POLYESTER