FLTWC0319-20-9

Users should evaluate the suitability of this product for their application. Specications are subject to change without notice.
Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specication, without notication to Buyer.
1/ COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE
ADDED TO THE PART NUMBER. AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
Page 1 of 2
TE Connectivity, TE connectivity (logo), TE (logo), and Raychem are trademarks.
Raychem Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-227-8816
Fax: 1-650-361-6297
DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL.
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
© 2005-2011 Tyco Electronics Corporation,. All rights reserved.
SPECIFICATION CONTROL DRAWING
FLTW+0319
GENERAL PURPOSE HOOKUP WIRE, MODIFIED POLYESTER-INSULATED, 600 VOLT 4-18-11 L
The complete requirements for procuring the wire described herein shall consist of this document and the issue in effect of
Raychem Specication WCD 3106, UL Subject 758, Style 10208, File E303150 and carries UL labels to this effect.
TITLE
Date Revision
CONSTRUCTION DETAILS
PART NUMBER
1/
WIRE
SIZE
(AWG)
CONDUCTOR
STRANDING
(number x AWG)
NOMINAL
CONDUCTOR
DIAMETER
(in.) (mm)
FINISHED WIRE
MAXIMUM
RESISTANCE
AT 20°C
(ohms/1000 ft.)
(ohms/km)
DIAMETER
(in.) (mm)
NOMINAL
WEIGHT
(lbs/1000 ft.)
(kg/km)
MINIMUM NOMINAL MAXIMUM
FLTWB0319-20-* 20 7 x 28 .038 (.965) 10.6 (34.8) .054 (1.37) .056 (1.42) .058 (1.47) 4.2 (6.25)
FLTWC0319-24-* 24 19 x 36 .024 (.610) 26.7 (87.6) .036 (.914) .038 (.965) .040 (1.02) 2.2 (3.27)
FLTWC0319-22-* 22 19 x 34 .030 (.762) 16.9 (55.4) .044 (1.12) .046 (1.17) .048 (1.22) 2.8 (4.17)
FLTWC0319-20-* 20 19 x 32 .038 (.965) 10.6 (34.8) .054 (1.37) .056 (1.42) .058 (1.47) 4.4 (6.55)
FLTWC0319-18-* 18 19 x 30 .047 (1.19) 6.66 (21.9) .063 (1.60) .065 (1.65) .067 (1.70) 6.3 (9.38)
FLTWC0319-16-* 16 19 x 29 .059 (1.50) 4.82 (15.8) .076 (1.93) .079 (2.01) .082 (2.08) 8.6 (12.8)
FLTWC0319-14-* 14 19 x 27 .072 (1.83) 3.05 (10.0) .092
(2.34) .096 (2.44) .100 (2.54) 13.8 (20.5)
FLTWD0319-12-* 12 37 x 28 .090 (2.29) 2.01 (6.59) .110 (2.79) .114 (2.90) .118 (3.00) 22.9 (34.1)
FLTWD0319-10-* 10 37 x 25 .113 (2.87) 1.26 (4.13) .133 (3.38) .137 (3.48) .141 (3.58) 35.1 (52.2)
CONDUCTOR - BARE COPPER
INSULATION - FLAME RETARDED,
MODIFIED POLYESTER
SPECIFICATION CONTROL DRAWING
2 of 2 L
FLTW+0319
Page
Revision
SCD
WIRE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 135°C
VOLTAGE RATING: 600 volts (rms) at sea level
INSULATION ELONGATION AND TENSILE STRENGTH:
Elongation, 230% (minimum)
Tensile Strength, 5200 lbf/in
2
(minimum)
INSULATION FLAWS:
Spark Test, 6.0 kV (rms)
Impulse Dielectric Test, 8.0 kV (peak)
INSULATION THICKNESS: .005 inch (minimum), .006 inch (minimum average)
SHRINKAGE: 125°C for 1 hour, 0.125 in. (maximum) per end
THERMAL STABILITY: 167°C for 168 hours,
Elongation Retention, 75% (minimum)
Tensile Strength Retention, 55% (minimum)
VOLTAGE WITHSTAND (Post Environmental): 1500 volts (rms), 60 Hz
PART NUMBER: The “+” in the part number in the upper right hand corner of pages 1 and 2
shall be replaced with a letter designator to dene conductor stranding (see part numbers in table).
B = 7 Strands C = 19 Strands D = 37 Strands
The “*” in the part numbers on page 1 shall be replaced by a color code designator.
1/ Example: AWG 20, 19 strands, white: FLTWC0319-20-9
AWG 20, 19 strands, white with black stripe: FLTWC0319-20-90
1/ See footer section on page 1

FLTWC0319-20-9

Mfr. #:
Manufacturer:
TE Connectivity
Description:
Hook-up Wire FLTWC0319-20-9
Lifecycle:
New from this manufacturer.
Delivery: