Absolute maximum ratings & operating conditions LM111-LM211-LM311
4/14
2 Absolute maximum ratings & operating conditions
Table 1. Absolute maximum ratings (AMR)
Symbol Parameter Value Unit
V
CC
Supply voltage 36 V
V
id
Differential input voltage ±30 V
V
i
Input voltage
(1)
1. This rating applies for ±15V supplies. The positive input voltage limit is 30V above the negative. The
negative input voltage is equal to the negative supply voltage or 30V below the positive supply, whichever
is less.
±15 V
V
(1-4)
Ground to negative supply voltage 30 V
V
(7-4)
Output to negative supply voltage
LM111-LM211
LM311
50
40
V
Output short-circuit duration 10 s
Voltage at strobe pin V
CC
+
-5 V
p
d
Power dissipation
(2)
DIP8
SO-8
2. P
d
is calculated with T
amb
= +25°C, T
j
= +150°C and R
thja
= 100°C/W for the DIP8 package, and
R
thja
= 175°C/W for the SO-8 package.
1250
710
mW
T
j
Junction temperature +150 °C
T
stg
Storage temperature range -65 to +150 °C
Table 2. Operating conditions
Symbol Parameter Value Unit
V
CC
Supply voltage 5 to ±15 V
T
oper
Operating free-air temperature range
LM111
LM211
LM311
-55 to +125
-40 to +105
0 to +70
°C