8330-FG19-PROP-LXAB009-3A

Magnetic and Hydraulic-Magnetic Circuit Breaker 8330-...
www.e-t-a.
de
2013/14
4 - 4
4
Dimensions – push and push/pull versions
47.09
±0.76
37.69
±0.508
28.58
±0.76
1.484
±.020
1.854
±.030
1.125
±.030
ON
OFF
10.16
.400
3/8" 8-32 THD
3.18
.125
A
push-pull
push to reset
double
LOAD
LINE
tab (Q.C.)
33.12
±0.508
single pole
Push-Pull actuator
Push to reset actuator
1.304
±.020
17.27
±0.508
.680
±.020
1.375
15.88
.625
34.93
flat
39.24
±0.508
1.545
±.020
5.59
±0.76
.200
±.030
panel cut-out
47.09
±0.76
37.69
±0.508
28.58
±0.76
1.484
±.020
1.854
±.030
1.125
±.030
ON
OFF
10.16
.400
3/8" 8-32 THD
LOAD
LINE
3.18
.125
A
OFF
ON flush
snap-in bushing
ø15.87
13.82
.544
ø9.53
+0.25
.375 dia
+.010
4.11
±0.05
.162
±.002
Snap-in bushing actuator (shown with push to reset actuator)
5.59
±0.76
.200
±.030
OFF
ON flush
10.16
.400
panel cut-out
.625 dia
Button marking orientation
push-pull only
20
LINE
12.7
/ .500
±
0.76
±
.030
OFF
7.11
/ .280
±
0.76
±
.030
ON
A [mm / inch]
1.375
34.93
flat
20
This is a metric design and millimeter dimensions take precedence (
mm
)
inch
double
single pole
Dual colour rocker style Indicate “ON”
3.18
tab.(QC) terminals
38.86
±0.508
1.53
±.020
1.56
39.62
48.26
±0.76
28.58
±0.76
1.90
±.030
1.125
±.030
ON
OFF
LOAD
LINE
.125
2.54
9.40 max.
.370 max.
.100
19.56
.770
24.64
.970
9.40
±0.38
.370
±.015
10.16
.400
42.67
±0.508
1.68
±.020
1.56
39.62
28.58
±0.76
1.125
±.030
LOAD
LINE
.125
2.54
9.40 max.
.370 max.
.100
35.41
1.394
24.64
.970
9.40
±0.38
.370
±.015
10.16
.400
48.26
±0.76
1.90
±.030
3.18
ON
OFF
6.3
15.88
.248
.625
single pole
Indicate “OFF”
double pole
OFF
ON
Rockerguard configuration (panel hardware 9)
dimensions also apply to double pole
LOAD
LINE
7.75
±0.508
.305
±.020
26.67
±0.508
1.05
±.020
17.14
±0.508
.675
±.020
panel cut-out
A
[mm / inch]
1.57 / .062
35.18
+0.130
/ 1.385
+.005
single pole
panel
thickness
[mm / inch]
2.36 / .093
3.18 / .125
36.07
+0.130
/ 1.42
+.005
37.08
+0.130
/ 1.46
+.005
A
33.76
+0.13
.710
+.005
1.329
+.005
double pole
A
18.3
+0.13
6.3
17.27
±0.508
.248
.680
±.020
33.12
±0.508
1.304
±.020
OFF
ON
LOAD
LINE
OFF
ON
Standard rocker style
LOAD
LINE
9.14
±0.76
.360
±.030
flat rocker style
LOAD
LINE
9.14
±0.76
.360
±.030
Dimensions – flange mounted version
Magnetic and Hydraulic-Magnetic Circuit Breaker 8330-...
www.e-t-a.
de
2013/14
4 - 5
4
… times rated current
0.1
0.01
0.001
10000
1000
12 4 6
100
10
1
30 5 7 9 10 11
Curve OP (instantaneous)
Trip time in seconds
Other characteristic curves to special order
(e. g. with impulse delay for inrush peaks).
N.B. All curves will only be maintained if the escutcheon is
mounted on a vertical surface.
1.5
… times rated current
0.1
0.01
0.001
10000
1000
12 4 6
100
10
1
30 5 7 9 10 11
Curve CS, CD (short delay)
Trip time in seconds
1.5
1.35
Curve BS, BD (medium delay)
… times rated current
0.1
0.01
0.001
10000
1000
12 4 6
100
10
1
30 5 7 9 10 11
Trip time in seconds
1.5
1.35
8
12
8
12
8
12
Splash cover 1/2"
X 221 434 01
(degree of protection IP65)
ø6.5
21.4
15.9
.256
.843
.626
Typical time/current characteristics Accessories
This is a metric design and millimeter dimensions take precedence (
mm
)
inch
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications wit-
hout notice is reserved.Product markings may not be exactly as the ordering codes. Errors
and omissions excepted.
Magnetic and Hydraulic-Magnetic Circuit Breaker 8330-...
www.e-t-a.
de
2013/14
4 - 6
4

8330-FG19-PROP-LXAB009-3A

Mfr. #:
Manufacturer:
E-T-A Circuit Breakers
Description:
Circuit Breakers
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union