7. Physical Characteristics
Test Item
Condition of Test
Performance Requirements
7-1 Mechanical
Shock
The transducer shall be measured after being
applied three impacts in plus and minus
directions of three mutually perpendicular
planes.
The shock is specified as 29400m/s
2
(3000G)
half sine pulse of 0.3 ms duration.
No visible damage and the
measured values shall meet
Table 2.
7-2 Vibration The transducer shall be measured after being
applied vibration of amplitude of 1.5 mm with 10
to 55 Hz band of vibration frequency to each of 3
perpendicular directions for 2 hours.
( 5 minutes × 24 cycles )
7-3 Bend Strength
PCB
The transducer is soldered onto the center of
PCB (1.6 mm thickness) which is laid on the 2
small supporters spaced 90 mm.
PCB is deflected to 1 mm below from horizontal
level by the pressing force with 20 × 10. R10
stick. The force is supplied for 1 second, 5 times
repeatably.
No visible damage and the
measured values shall meet
Table 3.
7-4 Resistance to
Reflow
Soldering
The transducer shall be mounted on PCB, then
measured after being applied following reflow
conditions.
<Test flow>
Pre-heating :
60 to 150 sec. at 150 to 180 °C
Heating :
Within 60 sec. at 200 °C (or more)
Within 30 sec. at 250 °C (or more)
Peak Temperature:
Within 10 sec. at 260 °C
Shock sensor should be tested 2 times of this
test flow.
PCB size : 115 × 80 × 0.8 mm
A
fter being placed at ambient conditions for 8
hours, the transducer shall be measured.
No visible damage and the
measured values shall meet
Table 2.
7-5 Solderability End terminals are immersed in rosin for
5 seconds then immersed in soldering bath of
+230±5°C for 3±0.5 seconds.
75% min. end terminals shall
be wet with solder.
7-6 Washability See Table 1. No visible damage and the
measured values shall meet
Table 2.
Part
Stick
PCB
45
45
10
20
R10
φ
5 Supporter
±
1 off-Cente
1
Unit: mm
Load
Deflection
Reference only P.5/15
MURATA MANUFACTURING CO., LTD
Table 1. Wash
Cleaning
Solvent
Item
Alcohol
(Iso-propanol)
Water
(Tap water,
Demineralized
water)
Cleaning Water
Solution
(Cleanthrough
750H, Pine alpha
100S )
Silicon
(Techno care FRW)
Temperature
Difference:dT *1
[dT = Component
- solvent]
dT<100°C
Condition
(1) Ultrasonic
Wash
1 minute max. in above solvent at 60°C max.
( Frequency : 28 kHz, Output : 20 W/L )
(2) Immersion
Wash
5 minutes max. in above solvent at 60°C max.
(3) Shower or
Rinse Wash
5 minutes max. in above solvent at 60°C max.
(4) Drying
1 to 5 minutes. by air blow at 80°C max.
*1 ex. In case the component at 90°C immerses into cleaning solvent at 60°C,
then dT = 30°C.
Note(Wash)
1. Please insure the component is thoroughly evaluated in your application circuit.
2. The component may be damaged if it is washed with alkali cleaning solvent.
3. Flux should be washed out before use.
Reference only P.6/15
MURATA MANUFACTURING CO., LTD
8. Environmental Characteristics
Test Item
Condition of Test
Performance Requirements
8-1 High
Temperature
A
fter being placed in a thermal chamber with at
+85±2°C for 1000 hours and then being placed at
ambient conditions for 8 hours, the transducer shall be
measured.
The measured values shall
meet Table 2.
8-2 Low
Temperature
A
fter being placed in a thermal chamber with at
-40±2°C for 1000 hours and then being placed at
ambient conditions for 8 hours, the transducer shall be
measured.
The measured values shall
meet Table 2.
8-3 Humidity After being placed in a humidity chamber with
90 to 95% R.H. at +60±2°C for 500 hours
and the being placed at ambient conditions for
8 hours, the transducer shall be measured.
The measured values shall
meet Table 2.
8-4 Heat Shock After being kept at room temperature, the transducer
shall be placed in a thermal chamber at temperature of
-40°C.
A
fter 30 minutes at this temperature, the transducer
shall be immediately placed in a chamber at
temperature of +85°C.
After 30 minutes at this temperature, the transducer
shall be returned to -40°C again.
A
fter 250 of the above cycles, the transducer shall be
returned to ambient conditions where it shall remain for
8 hours prior to being measured.
The measured values shall
meet Table 2.
Table 2.
Electric Charge Sensitivity ±10% ( from initial value )
Table 3.
Capacitance ±10% ( from initial value )

PKGS-25SXAP1-R

Mfr. #:
Manufacturer:
Description:
Motion & Position Sensors Vibration Sensors 740pF 100M ohm 27kHz
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet