HG4-SS

HG
SPECIFICATIONS
Electrical life with DC load
Note: For DC inductive load, use of an arc extinguishing circuit is recommended.
20 AMP POWER RELAY
HG RELAYS
DC load Voltage, V DC Current, A Expected life (min. operations)
Resistive
24 15 5
×
10
5
125 0.8 5
×
10
5
Inductive (L/R
]
7 ms)
24 10 5
×
10
5
125 0.4 5
×
10
5
36
1.417
56
2.205
a
mm inch
a
HG2 34.0 1.339
HG3 50.0 1.969
HG4 68.0 2.667
FEATURES
Large capacity — 20 A 250 V AC resistive and 1.5 kW 3 phase
220 V AC motor loads
• High contact reliability after long use
• Usable with direct soldering,
quick-connect and plug-in terminals. (.250)
Contacts
Expected life (min. operations)
Life curve for AC types
Characteristics (at 60 Hz, 20°C 68°F)
Arrangement 2 Form C, 3 Form C, 4 Form C
Initial contact resistance, max.
(By voltage drop 6 V DC 1A)
15 m
Contact material Silver alloy
Nominal switching capacity 20 A 250 V AC (resistive)
Min. switching capacity
#1
100 mA, 5 V DC
Mechanical (at 180 cpm) AC type: 10
7
, DC type: 10
6
5101520
0
100
200
300
400
500
600
700
800
900
1,000
Load current, A
Operations, ×10
4
125 V AC cos
ϕ = 1
2
5
0
V
A
C
c
o
s
ϕ
=
1
Mechanical life : 10
7
Operating frequency:
180 op./min.
Maximum operating speed 20 cpm
Initial insulation resistance*
1
Min. 100 M at 500 V DC
Initial
breakdown
voltage*
2
Between open contacts 2,000 Vrms for 1 min.
Between contacts sets 2,000 Vrms for 1 min.
Between contacts and coil 2,000 Vrms for 1 min.
Operate time*
3
(approx.)
(at nominal voltage)
2 Form C type Max. 30 ms
3 Form C &
4 Form C type
Max. 40 ms
Release time
(without diode)*
3
(approx.)
(at nominal voltage)
2 Form C type Max. 30 ms
3 Form C &
4 Form C type
Max. 40 ms
Shock resistance
Functional*
4
98 m/s
2
{10 G} (except for the
contact moving direction)
Destructive*
5
980 m/s
2
{100 G}
Vibration resistance
Functional*
6
10 to 55 Hz
at 1 mm double amplitude
Destructive
10 to 55 Hz
at 2 mm double amplitude
Conditions for operation,
transport and storage*
7
(Not freezing and condensing at
low temperature)
Ambient
temp.
–50°C to +40°C
–58°F to +104°F
Humidity 5 to 85% R.H.
Unit weight
2 Form C type Approx. 130 g 4.59 oz
3 Form C type Approx. 185 g 6.53 oz
4 Form C type Approx. 240 g 8.47 oz
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as “Initial breakdown voltage” section
*
2
Detection current: 10 mA
*
3
Excluding contact bounce time
*
4
Half-wave pulse of sine wave: 11ms; detection time: 10µs
*
5
Half-wave pulse of sine wave: 6ms
*
6
Detection time: 10µs
*
7
Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT
Electrical life with AC load
AC load Voltage, V AC Current, A
Expected life
(min. operations)
Resistive
(cos ϕ ] 1)
125
20 5×10
5
15 7.5×10
5
250
20 2×10
5
15 5×10
5
10 7.5×10
5
Inductive
(cos ϕ ] 0.4)
125
15 2×10
5
10 5×10
5
250
10 2×10
5
7.5 5×10
5
AC load Voltage, V AC Capacity, kW
Expected life
(min. operations)
Lamp 125
0.5 2×10
5
0.3 5×10
5
Motor
Single
phase
125
0.75 2×10
5
0.4 5×10
5
250
0.75 2×10
5
0.4 5×10
5
Three
phase
250
1.5 2×10
5
0.75 5×10
5
Note: In case of an electromagnet or exiting coil load (solenoid, etc.), the value of the motor or lamp load is applicable.
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
HG
TYPES AND COIL DATA
DC TYPES at 20
°
C 68
°
F
AC TYPES (50/60 Hz) at 60 HZ, 20
°
C 68
°
F
Notes:
Type Part No.
Nominal coil
voltage, V DC
Pick-up
voltage,
V DC (max.)
Drop-out
voltage,
V DC (min.)
Max.
allowable,
V DC voltage
Coil
resistance,
(
±
10%)
Nominal coil
current,
mA
Operating
power, W
HG2
(2 Form C)
HG2-DC6V 6 4.8 0.9 6.6 26.4 230 (approx.) 1.4
HG2-DC12V 12 9.6 1.8 13.2 100 119.6 (approx.) 1.4
HG2-DC24V 24 19.2 3.6 26.4 416 57.6 (approx.) 1.4
HG2-DC48V 48 38.4 7.2 52.8 1585 30.3 (approx.) 1.4
HG2-DC110V 110 88 16.5 121 7650 14.4 (approx.) 1.4
HG2-DC200V 200 160 20 220 27,800 7.2 (approx.) 1.4
HG3
(3 Form C)
HG3-DC6V 6 4.8 0.9 6.6 22.7 264 (approx.) 1.6
HG3-DC12V 12 9.6 1.8 13.2 89.5 134 (approx.) 1.6
HG3-DC24V 24 19.2 3.6 26.4 364 66 (approx.) 1.6
HG3-DC48V 48 38.4 7.2 52.8 1450 33.1 (approx.) 1.6
HG3-DC110V 110 88 16.5 121 6670 16.5 (approx.) 1.6
HG3-DC200V 200 160 20 220 23,800 8.4 (approx.) 1.6
HG4
(4 Form C)
HG4-DC6V 6 4.8 0.9 6.6 18.5 325 (approx.) 2.1
HG4-DC12V 12 9.6 1.8 13.2 71.4 168 (approx.) 2.1
HG4-DC24V 24 19.2 3.6 26.4 296 81.2 (approx.) 2.1
HG4-DC48V 48 38.4 7.2 52.8 1050 45.7 (approx.) 2.1
HG4-DC110V 110 88 16.5 121 5420 20.3 (approx.) 2.1
HG4-DC200V 200 160 20 220 15,500 12.9 (approx.) 2.1
Type Part No.
Nominal coil
voltage,
V AC
Pick-up
voltage,
V AC (max.)
Drop-out
voltage,
V AC (min.)
Max.
allowable,
V AC voltage
Inductance,
H
Nominal coil
current,
mA
Operating
power,
VA
HG2
(2 Form C)
HG2-AC6V 6 4.8 1.8 6.6 0.026 600 (approx.) 3.6
HG2-AC12V 12 9.6 3.6 13.2 0.104 300 (approx.) 3.6
HG2-AC24V 24 19.2 7.2 26.4 0.416 150 (approx.) 3.6
HG2-AC48V 48 38.4 14.4 52.8 1.660 75 (approx.) 3.6
HG2-AC115V 115 92 34.5 126.5 9.531 31.3 (approx.) 3.6
HG2-AC220V 220 176 66 242 34.96 16.4 (approx.) 3.6
HG2-AC240V 240 192 72 264 41.68 15 (approx.) 3.6
HG3
(3 Form C)
HG3-AC6V 6 4.8 1.8 6.6 0.018 864 (approx.) 5.2
HG3-AC12V 12 9.6 3.6 13.2 0.073 432 (approx.) 5.2
HG3-AC24V 24 19.2 7.2 26.4 0.290 216 (approx.) 5.2
HG3-AC48V 48 38.4 14.4 52.8 1.163 108 (approx.) 5.2
HG3-AC115V 115 92 34.5 126.5 6.648 45.2 (approx.) 5.2
HG3-AC220V 220 176 66 242 24.26 23.6 (approx.) 5.2
HG3-AC240V 240 192 72 264 29.06 21.6 (approx.) 5.2
HG4
(4 Form C)
HG4-AC6V 6 4.8 1.8 6.6 0.012 1264 (approx.) 7.6
HG4-AC12V 12 9.6 3.6 13.2 0.050 632 (approx.) 7.6
HG4-AC24V 24 19.2 7.2 26.4 0.199 316 (approx.) 7.6
HG4-AC48V 48 38.4 14.4 52.8 0.795 158 (approx.) 7.6
HG4-AC115V 115 92 34.5 126.5 4.557 66.1 (approx.) 7.6
HG4-AC220V 220 176 66 242 16.89 34 (approx.) 7.6
HG4-AC240V 240 192 72 264 19.87 31.6 (approx.) 7.6
TYPICAL APPLICATIONS
Industrial machinery, machine tools, food
processing and packing machines, office
machines, transportation equipment and
amusement devices.
ORDERING INFORMATION
Ex. HG 2 AC 240 V
Contact arrangement
(Note) Standard packing Carton: HG2 20 pcs.
HG3, HG4 10 pcs.
UL/CSA approved type is standard.
2: 2 Form C
3: 3 Form C
4: 4 Form C
Coil voltage
AC 6, 12, 24, 48, 115, 220, 240 V
DC 6, 12, 24, 48, 110, 200 V
Case: HG2 100 pcs.
HG3, HG4 50 pcs.
1. The coil current ranges is ±15% for AC (60 Hz), ±10% for DC (20°C 68°F).
2. These relays are applicable to a range of 80% to 110% of the nominal coil voltage.
However, it is recommended that the relay be used in a range of 85% to 110% of the
nominal coil voltage, taking the temporary voltage variation into consideration. For
AC types, when operating voltage is 70% of nominal coil voltage, buzzing will
occur, and a large amount of current will ow, burning the coil.
3. Each coil resistance of DC types is the measured value at coil temperature of
20°C 68°F. Please compensate the coil resistance by ±0.4%, each time the coil
temperature changes by ±1°C.
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
HG
DIMENSIONS
mm inch
ACCESSORIES
Please refer to MOUNTING METHOD for further information.
Note: Tapping-screw holes are provided on the cover top for direct mounting.
HG Relay
Screw terminal socket
for DIN rail assembly
(with hold-down clip)
Solder terminal socket
for rectangular hole
(with hold-down clip)
Bracket for direct mounting
HG2
(2 Form C)
HG2-SFD HG2-SS HP-BRACKET
1 pc.
HG3
(3 Form C)
HG3-SFD HG3-SS HP-BRACKET
2 pcs.
HG4
(4 Form C)
No screw terminal socket for
HG4 use 2 screw terminal
sockets (HG2-SFD)
HG4-SS HP-BRACKET
2 pcs.
HG2 (2 Form C)
8.4
.3317
.276
16
.630
20.5
.807
15
.591
34
1.339
56
2.205
17
.669
7 .276
8.5 .335
10.5 .413
7.5 .295
7.26 .286
36
1.417
2.5 DIA. 9 DEEP HOLE for
3 DIA. TAPPING SCREW
.098 DIA. .354 DEPTH
2.5 DIA. 8 DEEP HOLE for
3 DIA. TAPPING SCREW
.098 DIA. .315 DEPTH
AMP SERIES
FASTON 250
CONNECTORS
CAN BE USED
Schematic (Bottom view)
HG3 (3 Form C)
8.4
.331
8.4
.331
7
.276
16
.630
20.5
.807
17
.669
50
1.969
17
.669
17
.669
7 .276
10.5 .413
7.5 .295
7.26 .286
36
1.417
2.5 DIA. 9 DEEP HOLE for
3 DIA. TAPPING SCREW
.098 DIA. .354 DEPTH
2.5 DIA. 8 DEEP HOLE for
3 DIA. TAPPING SCREW
.098 DIA. .354 DEPTH
AMP SERIES
FASTON 250
CONNECTORS
CAN BE USED
8.5 .335
56
2.205
Schematic (Bottom view)
HG4 (4 Form C)
8.4
.331
8.4
.331
7
.276
16
.630
20.5
.807
34
1.339
68
2.667
17
.669
17
.669
17
.669
7 .276
10.5 .413
7.5 .295
7.26 .286
36
1.417
2.5 DIA. 9 DEEP HOLE for
3 DIA. TAPPING SCREW
.098 DIA. .354 DEPTH
2.5 DIA. 8 DEEP HOLE for
3 DIA. TAPPING SCREW
.098 DIA. .315 DEPTH
AMP SERIES
FASTON 250
CONNECTORS
CAN BE USED
8.5 .335
56
2.205
Schematic (Bottom view)
General tolerance: ±0.5 ±.020
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.

HG4-SS

Mfr. #:
Manufacturer:
Panasonic Industrial Devices
Description:
General Purpose Relays HG4-socket Solder termnal
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union