➜ Series 83 870 with cable output
■ IP 66/67
■ Metal case
■ cUL approval
Metal plunger
Characteristics Type of output
Standard Cable length 1 m
83 870 101
Standard Cable length 2 m
83 870 102
Standard Cable length 3 m
83 870 103
Standard Cable length 6 m
83 870 106
Plunger with 90° roller Cable length 1 m -
Plunger with 90° roller Cable length 2 m -
Plunger with 90° roller Cable length 3 m -
Plunger with 90° roller Cable length 6 m -
Mechanical characteristics
Sequence
Snap action
Minimum operating force (N) 10
Minimum operating force (Nm) -
Minimum total travel force (N) 30
Minimum total travel force (Nm) -
Min. positive opening travel (N) 28
Min. positive opening travel (Nm) -
Mechanical life millions of operations 10
Vertical approach speed 1 mm/min ➞ 0.5 m/s
Horizontal approach speed (30° cam) -
Weight (g) 170
Assigned impulse voltage (Uimp) - V 2500
Assigned insulation voltage (Ui) V 500
Thermal current (Ith) A 10
Low-load switching - Minimum voltage (V) 10
Low-load switching - Minimum current (mA) 100
Assigned working characteristics (EN 60 947.5.1, UL 508) A300 = AC15 240 V 3 A / 120 V 6 A Alternating current
Q150 = DC13 125 V 0.55 A Direct current
Electrical life according to IEC 947-5-1 appendix C 250 V 3 A AC15 500.000 operations
24 V 8 W DC13 500.000 operations
Electrical protection Integral protective earth conductor
Short-circuit protection device : IEC/EN 60947-5-1
Fuse 6 AgG
Approvals UL 508, UL 50
■ Contact type
■ Rear output
■ Protective scraper seal
■ Length of cable/connector/stripping
■ Special marking
Compact limit switch conforming to NFC 63 145
Main specifications
PRP
19,8 mm
CD 1,1 mm
PA
18 mm
POP
15,8mm
PFC
14,7mm
BK -BK
BN-BU
BK -BK
BN-BU
General characteristics