Series 83 870 with cable output
Series 83 870 with connector output
Series 83 870 with low level cable or connector output
Series 83 880 with cable output
Conformity to standards IEC/EN 60947.5.1
Dimensional conformity : NFC 63145
Low voltage directive : 73/23/EEC and 93/68/EEC
Declaration of incorporation in accordance with Machinery directive
89/392/EEC/IEC/EN : 60204.1
Protection against electric shocks NFC 20030 or IEC 60536 class 1, degree of pollution 3
Degree of protection IEC 60529 IP 66/67
Degree of protection according to NEMA 250 Type 1, 3, 4, 6, 13
Connections
5-core cable (UL) , 0.75 mm
2
AWG19, ext. Ø 7.3 mm
Operating temperature (°C) -25 +70°C
Compact limit switch conforming to NFC 63 145
General characteristics
Electrical characteristics
Series 83 870 with cable output
IP 66/67
Metal case
cUL approval
Metal plunger
Characteristics Type of output
Standard Cable length 1 m
83 870 101
Standard Cable length 2 m
83 870 102
Standard Cable length 3 m
83 870 103
Standard Cable length 6 m
83 870 106
Plunger with 90° roller Cable length 1 m -
Plunger with 90° roller Cable length 2 m -
Plunger with 90° roller Cable length 3 m -
Plunger with 90° roller Cable length 6 m -
Mechanical characteristics
Sequence
Snap action
Minimum operating force (N) 10
Minimum operating force (Nm) -
Minimum total travel force (N) 30
Minimum total travel force (Nm) -
Min. positive opening travel (N) 28
Min. positive opening travel (Nm) -
Mechanical life millions of operations 10
Vertical approach speed 1 mm/min 0.5 m/s
Horizontal approach speed (30° cam) -
Weight (g) 170
Assigned impulse voltage (Uimp) - V 2500
Assigned insulation voltage (Ui) V 500
Thermal current (Ith) A 10
Low-load switching - Minimum voltage (V) 10
Low-load switching - Minimum current (mA) 100
Assigned working characteristics (EN 60 947.5.1, UL 508) A300 = AC15 240 V 3 A / 120 V 6 A Alternating current
Q150 = DC13 125 V 0.55 A Direct current
Electrical life according to IEC 947-5-1 appendix C 250 V 3 A AC15 500.000 operations
24 V 8 W DC13 500.000 operations
Electrical protection Integral protective earth conductor
Short-circuit protection device : IEC/EN 60947-5-1
Fuse 6 AgG
Approvals UL 508, UL 50
Contact type
Rear output
Protective scraper seal
Length of cable/connector/stripping
Special marking
Compact limit switch conforming to NFC 63 145
Main specifications
PRP
19,8 mm
CD 1,1 mm
PA
18 mm
POP
15,8mm
PFC
14,7mm
BK -BK
BN-BU
BK -BK
BN-BU
General characteristics
Product adaptations
Metal roller plunger Metal plunger with
threaded barrel
Roller plunger - metal
with threaded barrel
Metal roller lever
(2 directions of attack)
83 871 101 83 874 101 83 872 101 83 873 101
83 871 102 83 874 102 83 872 102 83 873 102
83 871 103 83 874 103 83 872 103 83 873 103
83 871 106 83 874 106 83 872 106 83 873 106
83 875 101 - 83 876 101 -
83 875 102 - 83 876 102 -
83 875 103 - 83 876 103 -
83 875 106 - 83 876 106 -
10 10 10 -
---0.15
30 30 30 -
---0.35
30 28 28 -
---0.15
10 10 28 10
1 mm/min
0.5 m/s 1 mm/min 0.5 m/s 1 mm/min 0.5 m/s -
1 mm/min
0.3 m/s - 1 mm/min 0.3 m/s 1 mm/min 1.5 m/s
180 200 200 210
Function
Four-terminal double break two-way contact element (form Zb) with positive opening NC contacts. The 2 moving contacts are electrically isolated from
one another.
Snap-action contact
B
Brown
C
Black
D
Blue
E
Green-yellow
PRP
29,9 mm
PA
28 mm
POP
25,7 mm
PFC
24,7 mm
BK -BK
BN-BU
BK -BK
BN-BU
CD 1,1 mm
PRP
34,8 mm
PA
33 mm
POP
30,8 mm
PFC
29,7 mm
BK -BK
BN-BU
BK -BK
BN-BU
CD 1,1 mm
PRP
45 mm
PA
43,1 mm
POP
40,8 mm
PFC
39,8
m
BK -BK
BN-BU
BK -BK
BN-BU
CD 1,1 mm
PRP
PA
27°
POP
58°
PFC
69°
BK -BK
BN-BU
BK -BK
BN-BU
CD 14°
Principles
Zb
BU BK GN-YW
BN BK
1 2
23 4

83874113

Mfr. #:
Manufacturer:
Description:
Limit Switches EB THRDPLNGR BTMXIT 3M CBL
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union