2
SY10ELT28
SY100ELT28
Micrel
Symbol Rating Value Unit
V
CC
Power Supply Voltage –0.5 to +7.0 V
V
IN
Input Voltage 0 to +6.0 V
I
OUT
PECL Output Current –Continuous 50 mA
–Surge 100
T
A
Operating Temperature Range –40 to +85 °C
T
store
Storage Temperature Range –65 to +150 °C
θ
JA
Package Thermal Resistance –Still-Air (SOIC) 160 °C/W
(Junction-to-Ambient) –500lfpm (SOIC) 109
–Still-Air (MSOP) 206 °C/W
–500lfpm (MSOP) 155
θ
JC
Package Thermal Resistance (SOIC) 39 °C/W
(Junction-to-Case) (MSOP) 39
ABSOLUTE MAXIMUM RATINGS
(1)
T
A
= –40°CT
A
= +25°CT
A
= +85°C
Symbol Parameter Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit Condition
V
CC
Power Supply Voltage 4.75 5.0 5.5 4.75 5.0 5.5 4.75 5.0 5.5 V
I
CC
Power Supply Current — 23 40 — 22 40 — 25 40 mA
C
IN
Input Capacitance (SOIC) — — — — 0.75 ————pF
(MSOP) — — — — 1.1 ————pF
DC ELECTRICAL CHARACTERISTICS
(1)
V
CC
= +5V ±10%; V
EE
= 0V
NOTE:
1. 10/100KELT circuits are designed to meet the DC specifications shown in the above table after thermal equilibrium has been established. The circuit is
in a test socket or mounted on a printed circuit board and traverse airflow greater than 500lfpm is maintained. Input and output parameters vary 1:1 with
V
CC
. V
CC
can vary ±0.25V.
T
A
= –40°CT
A
= +25°CT
A
= +85°C
Symbol Parameter Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit Condition
V
OH
Output HIGH Voltage 3920 4010 4110 4020 4105 4190 4090 4185 4280 mV
50Ω V
CC
–2V
V
OL
Output LOW Voltage 3050 3200 3350 3050 3210 3370 3050 3227 3405 mV
50Ω V
CC
–2V
V
IH
Input HIGH Voltage 3770 — 4110 3870 — 4190 3940 — 4280 mV
(Single-Ended)
V
IL
Input LOW Voltage 3050 — 3500 3050 — 3520 3050 — 3555 mV
(Single-Ended)
V
IHCMR
Input HIGH Voltage
1.2 — V
CC
1.2 — V
CC
1.2 — V
CC
mV
Common Mode Range
(2)
10K PECL DC ELECTRICAL CHARACTERISTICS
(1)
V
CC
= +5.0V ±10%
NOTES:
1. 10/100KELT circuits are designed to meet the DC specifications shown in the above table after thermal equilibrium has been established. The circuit is
in a test socket or mounted on a printed circuit board and traverse airflow greater than 500lfpm is maintained.
2. V
IHCMR
(Min) varies 1:1 with GND, V
IHCMR
(Max) varies 1:1 with V
CC
.
NOTE:
1. Permanent device damage may occur if ABSOLUTE MAXIMUM RATINGS are exceeded. This is a stress rating only and functional operation is not implied
at conditions other than those detailed in the operational sections of this data sheet. Exposure to ABSOLUTE MAXIMUM RATlNG conditions for extended
periods may affect device reliability.