Electrical specification and ordering codes
R
25
Ω
No. of R/T
characteristic
B
25/85
K
B
0/100
K
B
25/100
K
Ordering code
+ = Resistance tolerance
G = ±2%
H = ±3%
5 k 8324 3483 3455 3497 ±1% B57541G1502+000
10 k 8307 3478 3450 3492 ±1% B57541G1103+000
10 k 7003 3612 3586 3625 ±1% B57541G1103+005
50 k 8342 3991 3967 4006 ±1% B57541G1503+000
100 k 8304 4072 4036 4092 ±1% B57541G1104+000
Reliability data
Test Standard Test conditions ∆R
25
/R
25
(typical)
Remarks
Storage in
dry heat
IEC
60068-2-2
Storage at upper
category temperature
T: 250 °C
t: 1000 h
< 3% No visible
damage
Storage in damp
heat, steady state
IEC
60068-2-67
Temperature of air: 85 °C
Relative humidity of air: 85%
Duration: 1000 h
< 2% No visible
damage
Rapid temperature
cycling
IEC
60068-2-14
Lower test temperature: 55 °C
Upper test temperature: 200 °C
Number of cycles: 1000
< 2% No visible
damage
Temperature measurement B57541G1
Glass-encapsulated sensors with insulation G1541
Page 3 of 23Please read Cautions and warnings and
Important notes at the end of this document.