NL17SG04
www.onsemi.com
4
AC ELECTRICAL CHARACTERISTICS Input t
r
= t
f
= 3.0 ns
Symbol Parameter Test Condition V
CC
(V)
T
A
= 255 C
T
A
=
-555C to +1255C
Min Typ Max Min Max Unit
t
PLH
,
t
PHL
Propagation Delay,
A to Y
C
L
= 10 pF,
R
L
= 1 MW
0.9 - 10.0 13.3 - 17.0
ns
1.1 to 1.3 - 8.7 11.2 - 14.0
1.4 to 1.6 - 4.9 8.5 - 10.0
1.65 to 1.95 - 3.8 6.2 - 6.7
2.3 to 2.7 - 2.6 3.9 - 4.4
3.0 to 3.6 - 2.1 3.1 - 3.7
C
L
= 15 pF,
R
L
= 1 MW
0.9 - 11.55 13.7 - 19.7
ns
1.1 to 1.3 - 7.2 10.8 - 15.6
1.4 to 1.6 - 5.4 9.3 - 11.2
1.65 to 1.95 - 4.2 6.9 - 7.1
2.3 to 2.7 - 2.8 4.4 - 5.0
3.0 to 3.6 - 2.3 3.4 - 3.9
C
L
= 30 pF,
R
L
= 1 MW
0.9 - 16.85 18.9 - 22.3
ns
1.1 to 1.3 - 10.2 13.4 - 17.5
1.4 to 1.6 - 7.4 13.1 - 15.9
1.65 to 1.95 - 5.6 9.2 - 9.6
2.3 to 2.7 - 3.7 5.7 - 6.1
3.0 to 3.6 - 2.9 4.4 - 4.8
C
IN
Input Capacitance 0 to 3.6 3 - - - pF
C
PD
Power Dissipation
Capacitance (Note 5)
f = 10 MHz 0.9 to 3.6 - 4 - - - pF
Product parametric performance is indicated in the Electrical Characteristics for the listed test conditions, unless otherwise noted. Product
performance may not be indicated by the Electrical Characteristics if operated under different conditions.
5. C
PD
is defined as the value of the internal equivalent capacitance which is calculated from the operating current consumption without load.
Average operating current can be obtained by the equation: I
CC(OPR
)
= C
PD
V
CC
f
in
+ I
CC
. C
PD
is used to determine the no−load dynamic
power consumption; P
D
= C
PD
V
CC
2
f
in
+ I
CC
V
CC
.