Document Number: 94101 For technical questions, contact: diodestech@vishay.com
www.vishay.com
Revision: 09-Dec-09 1
Fast Soft Recovery
Rectifier Diode, 30 A
30EPF..PbF, 30CPF..PbF Soft Recovery Series
Vishay High Power Products
FEATURES/DESCRIPTION
The 30EPF..PbF and 30CPF..PbF soft recovery
rectifier series has been optimized for combined
short reverse recovery time and low forward
voltage drop.
The glass passivation ensures stable reliable
operation in the most severe temperature and power cycling
conditions.
30CPF series is a drop in replacement for 25CPF series
(parallel connection only).
This product series has been designed and qualified for
industrial level.
Compliant to RoHS directive 2002/95/EC.
APPLICATIONS
• Output rectification and freewheeling in inverters,
choppers and converters
• Input rectifications where severe restrictions on conducted
EMI should be met
PRODUCT SUMMARY
V
F
at 30 A < 1.41 V
t
rr
95 ns
V
RRM
1000 V to 1200 V
30CPF..PbF30EPF..PbF
TO-247AC modified
TO-247AC
2
1
3
Cathode
Anode
Base
common
cathode
2, 4
Anode
1
Anode
3
Base
common
cathode
MAJOR RATINGS AND CHARACTERISTICS
SYMBOL CHARACTERISTICS VALUES UNITS
I
F(AV)
Sinusoidal waveform 30 A
V
RRM
1000 to 1200 V
I
FSM
350 A
V
F
30 A, T
J
= 25 °C 1.41 V
t
rr
1 A, 100 A/µs 95 ns
T
J
- 40 to 150 °C
VOLTAGE RATINGS
PART NUMBER
V
RRM
, MAXIMUM PEAK
REVERSE VOLTAGE
V
V
RSM
, MAXIMUM NON-REPETITIVE
PEAK REVERSE VOLTAGE
V
I
RRM
AT 150 °C
mA
30EPF10PbF, 30CPF10PbF 1000 1100
6
30EPF12PbF, 30CPF12PbF 1200 1300
ABSOLUTE MAXIMUM RATINGS
PARAMETER SYMBOL TEST CONDITIONS VALUES UNITS
Maximum average forward current I
F(AV)
T
C
= 95 °C, 180° conduction half sine wave 30
A
Maximum peak one cycle
non-repetitive surge current
I
FSM
10 ms sine pulse, rated V
RRM
applied 300
10 ms sine pulse, no voltage reapplied 350
Maximum I
2
t for fusing I
2
t
10 ms sine pulse, rated V
RRM
applied 450
A
2
s
10 ms sine pulse, no voltage reapplied 636
Maximum I
2
√t for fusing I
2
√t t = 0.1 ms to 10 ms, no voltage reapplied 6360 A
2
√s
* Pb containing terminations are not RoHS compliant, exemptions may apply