Nexperia
74LVC1G3157
2-channel analog multiplexer/demultiplexer
74LVC1G3157 All information provided in this document is subject to legal disclaimers. © Nexperia B.V. 2017. All rights reserved.
Product data sheet Rev. 7 — 14 February 2017
4 / 26
6.2 Pin description
Table 3. Pin description
Symbol Pin Description
Y1 1 independent input or output
GND 2 ground (0 V)
Y0 3 independent input or output
Z 4 common output or input
V
CC
5 supply voltage
S 6 select input
7 Functional description
Table 4. Function table
[1]
Input S Channel on
L Y0
H Y1
[1] H = HIGH voltage level;
L = LOW voltage level.
8 Limiting values
Table 5. Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V).
Symbol Parameter Conditions Min Max Unit
V
CC
supply voltage -0.5 +6.5 V
V
I
input voltage
[1]
-0.5 +6.5 V
I
IK
input clamping current V
I
< -0.5 V or V
I
> V
CC
+ 0.5 V -50 - mA
I
SK
switch clamping current V
I
< -0.5 V or V
I
> V
CC
+ 0.5 V - ±50 mA
V
SW
switch voltage enable and disable mode
[2]
-0.5 V
CC
+ 0.5 V
I
SW
switch current V
SW
> -0.5 V or V
SW
< V
CC
+ 0.5 V - ±50 mA
I
CC
supply current - 100 mA
I
GND
ground current -100 - mA
T
stg
storage temperature -65 +150 °C
P
tot
total power dissipation T
amb
= -40 °C to +125 °C
[3]
- 250 mW
[1] The minimum input voltage rating may be exceeded if the input current rating is observed.
[2] The minimum and maximum switch voltage ratings may be exceeded if the switch clamping current rating is observed.
[3] For SC-88 and SC-74 packages: above 87.5 °C the value of P
tot
derates linearly with 4.0 mW/K.
For XSON6 and X2SON6 packages: above 118 °C the value of P
tot
derates linearly with 7.8 mW/K.
Nexperia
74LVC1G3157
2-channel analog multiplexer/demultiplexer
74LVC1G3157 All information provided in this document is subject to legal disclaimers. © Nexperia B.V. 2017. All rights reserved.
Product data sheet Rev. 7 — 14 February 2017
5 / 26
9 Recommended operating conditions
Table 6. Recommended operating conditions
Symbol Parameter Conditions Min Typ Max Unit
V
CC
supply voltage 1.65 - 5.5 V
V
I
input voltage 0 - 5.5 V
V
SW
switch voltage enable and disable mode
[1]
0 - V
CC
V
T
amb
ambient temperature -40 - +125 °C
V
CC
= 1.65 V to 2.7 V
[2]
- - 20 ns/VΔt/ΔV input transition rise and fall rate
V
CC
= 2.7 V to 5.5 V
[2]
- - 10 ns/V
[1] To avoid sinking GND current from terminal Z when switch current flows in terminal Yn, the voltage drop across the bidirectional switch must not exceed
0.4 V. If the switch current flows into terminal Z, no GND current will flow from terminal Yn. In this case, there is no limit for the voltage drop across the
switch.
[2] Applies to control signal levels.
10 Static characteristics
Table 7. Static characteristics
At recommended operating conditions; voltages are referenced to GND (ground 0 V).
-40 °C to +85 °C -40 °C to +125 °CSymbol Parameter Conditions
Min Typ
[1]
Max Min Max
Unit
V
CC
= 1.65 V to 1.95 V 0.65V
CC
- - 0.65V
CC
- V
V
CC
= 2.3 V to 2.7 V 1.7 - - 1.7 - V
V
CC
= 3 V to 3.6 V 2.0 - - 2.0 - V
V
IH
HIGH-level
input voltage
V
CC
= 4.5 V to 5.5 V 0.7V
CC
- - 0.7V
CC
- V
V
CC
= 1.65 V to 1.95 V - - 0.35V
CC
- 0.35V
CC
V
V
CC
= 2.3 V to 2.7 V - - 0.7 - 0.7 V
V
CC
= 3 V to 3.6 V - - 0.8 - 0.8 V
V
IL
LOW-level
input voltage
V
CC
= 4.5 V to 5.5 V - - 0.3V
CC
0.3V
CC
V
I
I
input leakage
current
pin S; V
I
= 5.5 V or GND;
V
CC
= 0 V to 5.5 V
[2]
- ±0.1 ±1 - ±1 μA
I
S(OFF)
OFF-state
leakage current
V
CC
= 5.5 V; see Figure 7
[2]
- ±0.1 ±0.2 - ±0.5 μA
I
S(ON)
ON-state
leakage current
V
CC
= 5.5 V; see Figure 8
[2]
- ±0.1 ±1 - ±2 μA
I
CC
supply current V
I
= 5.5 V or GND;
V
SW
= GND or V
CC
;
V
CC
= 1.65 V to 5.5 V
[2]
- 0.1 4 - 4 μA
ΔI
CC
additional
supply current
pin S; V
I
= V
CC
- 0.6 V;
V
CC
= 5.5 V;
V
SW
= GND or V
CC
[2]
- 5 500 - 500 μA
C
I
input
capacitance
- 2.5 - - - pF
Nexperia
74LVC1G3157
2-channel analog multiplexer/demultiplexer
74LVC1G3157 All information provided in this document is subject to legal disclaimers. © Nexperia B.V. 2017. All rights reserved.
Product data sheet Rev. 7 — 14 February 2017
6 / 26
-40 °C to +85 °C -40 °C to +125 °CSymbol Parameter Conditions
Min Typ
[1]
Max Min Max
Unit
C
S(OFF)
OFF-state
capacitance
- 6.0 - - - pF
C
S(ON)
ON-state
capacitance
- 18 - - - pF
[1] Typical values are measured at T
amb
= 25 °C.
[2] These typical values are measured at V
CC
= 3.3 V
10.1 Test circuits
I
S
001aac358
S
Z
Y0
Y1
V
CC
GND
switch
switch
1
1
2
2
V
IL
V
IH
S
V
IL
or V
IH
V
I
V
O
V
I
= V
CC
or GND and V
O
= GND or V
CC
.
Figure 7. Test circuit for measuring OFF-state leakage current
I
S
001aac359
S
Z
Y0
Y1
V
CC
GND
switch
switch
1
1
2
2
V
IL
V
IH
S
V
O
V
IL
or V
IH
V
I
V
I
= V
CC
or GND and V
O
= open circuit.
Figure 8. Test circuit for measuring ON-state leakage current

74LVC1G3157GXZ

Mfr. #:
Manufacturer:
Nexperia
Description:
Multiplexer Switch ICs 74LVC1G3157GX/X2SON6/REEL 7" Q
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union