CPC1593GS

I
NTEGRATED
C
IRCUITS
D
IVISION
www.ixysic.com
DS-CPC1593-R01
1
CPC1593
RoHS
2002/95/EC
e
3
Pb
Single-Pole, Normally Open OptoMOS
®
Relay
Integrated Current Limit with Voltage and Thermal Protection
Part # Description
CPC1593G 6-Pin DIP (50/Tube)
CPC1593GS 6-Pin Surface Mount (50/Tube)
CPC1593GSTR 6-Pin Surface Mount, Tape & Reel (1000/Reel)
Parameter Rating Units
Load Voltage 600 V
P
Load Current ±120 mA
On-Resistance (max) 35
Input Control Current 2 mA
Applications
Features
Description
Ordering Information
Block Diagram
Integrated Active Current-Limit with
Over-Voltage Protection
Thermal Regulation
600V
P
Blocking Voltage
Guaranteed Turn-On: 2mA Input Control Current
3750V
rms
Input/Output Isolation
Low Drive Power Requirements
(TTL/CMOS Compatible)
Arc-Free With No Snubbing Circuits
No EMI/RFI Generation
Switching Characteristics of
Normally Open Devices
Approvals
Form-A
I
F
I
LOAD
10%
90%
t
on
t
off
In-Rush Current Control
Heating, Ventilation, Air Conditioning Control (HVAC)
Security Systems
Power Supplies
Home Appliances
IC Equipment Protection
Instrumentation
Medical Equipment—Patient/Equipment Isolation
Aerospace
Industrial Controls
Thermal
Management
Gate Drive
Control
Current Limit
and
Over-Voltage
Protection
+
V
F
-
LOAD
LOAD
UL Recognized Component: File E76270
CSA Certified Component: Certificate 1172007
EN/IEC 60950-1 Certified Component:
TUV Certificate: B 10 05 49410 006
The CPC1593 is a normally open (1-Form-A)
Solid State Relay that incorporates load current
limiting with over-voltage protection and thermal
management. This self-resetting triple protection
scheme protects not only the CPC1593’s load,
but also the CPC1593 itself, thus creating a highly
effective switching mechanism that is designed to
survive in the harshest operating environments.
Over-voltage protection is activated when the voltage
across the switch is greater than 21V and the
device is in current limit. The over-voltage protection
deactivates the switch while allowing a restricted
load current of less than 100A to fl ow. When the
voltage across the switch falls below the over-voltage
threshold, the switches reactivate. If the fault persists,
then these responses will repeat.
The CPC1593 is designed for use in AC
environments where fault conditions can persist for
long periods of time, and where, upon removal of
the fault, return to normal operation is expected. The
CPC1593 is designed to survive extended power
cross conditions.
I
NTEGRATED
C
IRCUITS
D
IVISION
www.ixysic.com
2
R01
CPC1593
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Absolute Maximum Ratings @ 25ºC
Parameter Ratings Units
Blocking Voltage 600 V
P
Reverse Input Voltage 5 V
Input Control Current 50 mA
Peak (10ms) 1 A
Input Power Dissipation
1
150 mW
Total Power Dissipation
2
800 mW
Isolation Voltage, Input to Output (60 Seconds) 3750 V
rms
Operational Temperature (T
A
) -40 to +85 °C
Storage Temperature -40 to +125 °C
1
Derate linearly 1.33 mW / ºC
2
Derate linearly 6.67 mW / ºC
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics
Current Limit
AC/DC Configuration I
F
=5mA, V
L
=13V, t=5ms
I
LMT
±190 ±225 ±285
mA
DC Configuration I
F
=5mA, V
L
=6.5V, t=5ms 360 430 570
Over-Voltage Threshold I
F
=5mA V
TH
17.5 21 - V
On-Resistance
AC/DC Configuration I
F
=5mA, I
L
=120mA
R
ON
15 23 35
DC Configuration I
F
=5mA, I
L
=220mA 3.75 7.38 11.75
Off-State Leakage Current V
L
=600V I
LEAK
-- 1A
Switching Speeds
Turn-On
I
F
=5mA, I
L
=100mA
t
on
-
1.2
2ms
Turn-Off t
off
0.3
Output Capacitance I
F
=0mA, V
L
=20V
C
O
-18 - pF
Input Characteristics
Input Control Current to Activate I
L
=100mA I
F
- 0.56 2 mA
Input Control Current to Deactivate I
L
<1AI
F
0.2 0.389 - mA
LED Forward Voltage I
F
=5mA V
F
0.9 1.24 1.4 V
Reverse Input Current V
F
= -5V I
R
--10A
Common Characteristics
Input to Output Capacitance - C
I/O
- 0.5 - pF
Electrical Characteristics @ 25ºC
Parameter Symbol Configuration Min Typ Max Units
Load Current, Continuous
I
L
AC/DC - - 120 mA
rms
/ mA
DC
DC-Only - - 250 mA
DC
Input Control Current I
F
-3510mA
Operating Temperature T
A
- -40 - +85 ºC
Recommended Operating Conditions
1
3
2
4
5
6
+
Do Not Use
Load
Do Not Use
Load
AC/DC Configuration
V
F
1
3
2
4
5
6
+
Do Not Use
+ Load
– Load
DC Only Configuration
V
F
I
NTEGRATED
C
IRCUITS
D
IVISION
CPC1593
www.ixysic.com
3
R01
PERFORMANCE DATA @25ºC (Unless Otherwise Noted)*
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application
department.
V
TH
I
LMT
Over Voltage De-Activation Delay
Over Voltage Re-Activation Delay
Current Through Switch
Time
Line Voltage
V
TH
I
LMT
CPC1593 Waveforms: R
L
=0
Temperature (ºC)
-40 -20 0 20 40 60 80 100
LED Forward Voltage (V)
1.10
1.15
1.20
1.25
1.30
1.35
Typical LED Forward Voltage Drop
vs. Temperature
(I
F
=5mA, I
L
=100mA)
LED Current (mA)
1234567891011
Turn-On Time (ms)
0.0
0.5
1.0
1.5
2.0
2.5
Typical Turn-On Time
vs. LED Forward Current
(I
L
=100mA)
T
A
=85ºC
T
A
=25ºC
T
A
=-40ºC
LED Current (mA)
1234567891011
Turn-Off Time (ms)
0.0
0.1
0.2
0.3
0.4
0.5
Typical Turn-Off Time
vs. LED Forward Current
(I
L
=1mA)
T
A
=85ºC
T
A
=25ºC
T
A
=-40ºC
Temperature (ºC)
-40 -20 0 20 40 60 80 100
LED Current (mA)
0.0
0.1
0.2
0.3
0.4
0.5
Typical I
F
for Switch Operation
vs. Temperature
(I
L
=100mA)
Temperature (ºC)
-40 -20 0 20 40 60 80 100
Turn-On Time (ms)
0.0
0.5
1.0
1.5
2.0
2.5
3.0
Typical Turn-On Time
vs. Temperature
(I
F
=5mA, I
L
=100mA)
Temperature (ºC)
-40 -20 0 20 40 60 80 100
Turn-Off Time (ms)
0.0
0.2
0.4
0.6
0.8
1.0
Typical Turn-Off Time
vs. Temperature
(I
F
=5mA, I
L
=1mA)

CPC1593GS

Mfr. #:
Manufacturer:
Description:
Solid State Relays - PCB Mount 1-Form-A 600V 6-Pin SM
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet