2891033

FL SWITCH 300...
3037_en_B PHOENIX CONTACT 4
Current
Current draw Inrush current
FL SWITCH 3004T-FX 230 mA (24 V DC) 9.2 A (2 ms)
FL SWITCH 3005 200 mA (24 V DC) 8.6 A (2 ms)
FL SWITCH 3005T 200 mA (24 V DC) 8.6 A (2 ms)
FL SWITCH 3008 210 mA (24 V DC) 8.6 A (2 ms)
FL SWITCH 3008T 210 mA (24 V DC) 8.6 A (2 ms)
FL SWITCH 3004T-FX ST 230 mA (24 V DC) 9.2 A (2 ms)
FL SWITCH 3006T-2FX 330 mA (24 V DC) 8.2 A (2 ms)
FL SWITCH 3006T-2FX ST 330 mA (24 V DC) 8.2 A (2 ms)
Port configurations
No. of RJ45 ports No. of fiber optic ports
FL SWITCH 3004T-FX 4 1 ( SC )
FL SWITCH 3005 5
FL SWITCH 3005T 5
FL SWITCH 3008 8
FL SWITCH 3008T 8
FL SWITCH 3004T-FX ST 4 1 ( ST )
FL SWITCH 3006T-2FX 6 2 ( SC )
FL SWITCH 3006T-2FX ST 6 2 ( ST )
Ethernet (RJ45)
Connection method RJ45
Transmission speed 10/100 MBit/s
Transmission length 100 m
Fiber optic interface
Connection method SC
Transmission speed 100 MBit/s (SC-D, full duplex)
Wavelength 1300/1310 nm
Transmission length 12.1 km (fiberglass with F-G 62.5/125 0.7 dB/km F1000)
3.3 km (fiberglass with F-G 62.5/125 2.6 dB/km F600)
7.1 km (fiberglass with F-G 50/125 0.7 dB/km F1200)
3.1 km (fiberglass with F-G 50/125 1.6 dB/km F800)
Electrical isolation/isolation of the voltage areas
Supply voltage/functional earth ground 500 V, 1 min
Mechanical tests
Shock test in acc. with IEC 60068-2-27 25g, 11 ms half-sine shock pulse
Vibration resistance in acc. with IEC 60068-2-6 5g, 150 Hz, Criterion 3
Free fall in acc. with IEC 60068-2-32 1 m
FL SWITCH 300...
3037_en_B PHOENIX CONTACT 5
4 Managed switch functions
Ease of use for everyone
FL SWITCH 300 switches include context-sensitive help for
hardware and firmware functions. Web viewing modes can be
configured for different user types, such as maintenance,
control engineers or network administrators, providing quick
access to data.
Monitor mode provides one-click access to read-only di-
agnostics – no logins and no searching for web pages
Administrative mode allows access to the complete
range of switch functions and customizing of the user-
mode web pages
User mode can be customized to include only those func-
tions that are actually used, whether for start up or on-go-
ing maintenance purposes. With one click, unwanted
web pages are hidden from the user.
Mix IT and high-performance redundancy
The extended ring redundancy protocol allows network re-
covery time in as little as 15ms (18ms between rings) and
configurations up to 134devices. Coupling of up to three rings
of 134 switches each allows redundancy systems of over 300
switches. Coupling rings and ring ports may only be con-
nected to other switches (no other devices allowed). Both ex-
tended ring and IEEE redundancy may be operated simulta-
neously in the switch. Complete IEEE STP/RSTP/MST
options, with the additional option of extended ring redun-
dancy, serves a broad range of IT compatability and industrial
performance-based applications.
Powerful network performance options
The FL SWITCH 300 provides a complete range of mes-
sage filtering and network performance-increasing functions.
Performance may be scaled from basic to increasingly so-
phisticated functions.
Tailor security functions to your facility
The FLSWITCH 300 provides a wide array of security func-
tions that can be tailored to guard against unauthorized net-
work access. Scaleable security measures can be used to
protect against unauthorized access by people, devices or
network communications.
Telnet Yes
SNMP V1, V2 Yes
Serial interface Password protected for basic
maintenance addressing and
major function access
Transfer of firmware and
configuration files
via TFTP
Web view simplification Monitor, user and adminis-
trative views. User mode is
customizable by account
type or individual.
Network addressing BOOTP or DHCP
IGMP snooping/query Yes; 256 multicast groups
and GMRP support
QoS: priority queus 4
QoS: ToS: COS diff serv Yes
Link aggregation trunking Yes; up to four ports com-
bined with LACP trunk con-
trol
Flow control User enable/disable by port
Bandwidth rate control by
message type by port
Yes - percent bandwidth by
message type to separate in-
gress/egress transfer rates
by port
Time synchronization SNTP
VLAN Static 16 port-based VLANs, 64
maximum; tagging-based
VLAN supported with >4000
address range
VLAN Dynamic (tagging
based)
GVRP
Secure people access: Gen-
eral
Enable/disable Web inter-
face and Telnet, 802.1x Ra-
dius Authentication
Secure people access: Man-
age access to switch config-
uration parameters
User login accounts, custom-
ization of read and read/write
access, and control of func-
tion access for each type of
account or on an individual
basis
Secure device access MAC address filtering (up to
24) by port; enable/disable
ports; and global MAC dis-
card
Secure network access SNMP V3 with encryption;
enable/disable SNMP; https
secure web access
FL SWITCH 300...
3037_en_B PHOENIX CONTACT 6
5 Structure
Figure 1 Structure (FL SWITCH 3006T-2FX shown)
1 Power supply/remote alarm connector
2 DB-9 serial port (RS-232)
3 Reset button
4 Power LEDs (US1/US2)
5 RJ45 ports
6 RJ45 port LEDs (LNK/ACT and 10/100 Mbps)
7 Fiber optic ports
8 Fiber optic port LEDs (LNK/ACT and 100 Mbps)
SW ITCH 3000
LINK/ACT
100
X2
LINK/ACT
100
X4
LINK/ACT
100
X6
LINK/
ACT
100
LINK/
ACT
100
US1 US2
LINK/ACT
100
X1
LINK/ACT
100
X3
LINK/ACT
100
X5
X7
X8
X6
Reset
US1 GNDUS2 GND R1 R2
1 2 3 4 5 6 7 8
1
2
3
4
5
6
7
8

2891033

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
Ethernet Modules FL SWITCH 3004T-FX
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet