ENP-360-12

Universal AC input / Full range
Built-in active PFC function
Energy efficiency Level
No load power consumption <0.5W
Comply with EISA 2007/DoE, NRCan and EU ErP
125% peak load capability
Fanless design, cooling by free air convection
Protection: Short circuit / Overload / Over voltage /
Over temperature
3 years warranty
Features Applications
Model Encoding
Description
Nominal voltage
Series name
ENP -- 360 24
Rated wattage
360W Level Desktop Type Power Supply
ENP-360 series
File Name:ENP-360-SPEC 2018-05-07
Land mobile radio system
Surveillance system
TV antenna facility
UL60950-1
ENP-360 series is a 360W desktop type power supply working perfectly for communication related
applications. Observing the standard 7 width size in the land mobile radio field, it provides the most
frequently used voltage in the communication field. With the rugged mechanical design along with the
high efficiency circuitry, it operates for the ambient temperature range -30 ~+70 under free air convection. ℃℃
IEC60950-1
SPECIFICATION
360W Level Desktop Type Power Supply
ENP-360 series
ENP-360-24 ENP-360-48ENP-360-12
MODEL
DC VOLTAGE
RATED CURRENT
RIPPLE & NOISE (max.) Note.3
OUTPUT
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.4
LINE REGULATION Note.5
LOAD REGULATION Note.6
SETUP, RISE TIME Note.7
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.8
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
ENVIRONMENT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
NO LOAD POWER CONSUMPTION
OVER TEMPERATURE
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
SHORT CIRCUIT
OVER VOLTAGE
PROTECTION
27.6V 55.2V13.8V
13A 6.5A26A
150mVp-p 350mVp-p150mVp-p
11.5 ~ 15V 23.5 ~ 30V 47.5 ~ 58.8V
±1.0% ±1.0%±1.0%
±0.5% ±0.5%±0.5%
±1.0% ±0.5%±2.0%
1000ms, 100ms at full load
20ms at full load
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
PF>0.98/115VAC, PF>0.95/230VAC at full load
93% 94%91%
COLD START 60Aat 230VAC
<3.5mA / 240VAC
<0.5W
Normally works within 110 ~ 125% rated output power for more than 3 seconds and switches to constant current limiting, with
auto-recovery after the peak load condition is removed
Protection type : Constant current limiting, recovers automatically after fault condition is removed
31 ~ 36.5V 62.1 ~ 72.9V
15.5 ~ 18.2V
Constant current limiting, if >125% rated power, with auto-recovery after the overload condition is removed
Protection type : Shut down o/p voltage, re-power on to recover
Shut down O/P voltage, recovers automatically after temperature goes down
IEC60950-1, UL60950-1 EAC TP TC 004 approved
,
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
-30 ~ +70 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH non-condensing
±℃ 0.05%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
147.5K hrs min. MIL-HDBK-217F (25 )
192*178*45.5mm (L*W*H)
1.5Kg; 10pcs/16Kg /1.38CUFT
3.8A/115VAC 1.9A/230VAC
AC CURRENT (Typ.)
16.3A 8.2A32.6A
359W
450W
359W
453W
359W
450W
0 ~ 13A 0 ~ 6.5A0 ~ 26A
CURRENT
WATTAGE
PEAK Note.2
PEAK Note.2
RATED
RATED
SAFETY &
EMC
(Note 9)
EMC IMMUNITY
EMC EMISSION
Parameter
Parameter
ESD
Radiated
EFT / Burst
Surge
Conducted
Magnetic Field
Voltage Dips and Interruptions
Conducted
Radiated
Harmonic Current
Voltage Flicker
EN55024
Standard
Standard
EN55032 (CISPR32) / FCC PART15 (CISPR22)
EN55032 (CISPR32) / FCC PART15 (CISPR22)
EN61000-3-2
EN61000-3-3
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
Test Level / Note
Test Level / Note
Level 3, 8KV air ; Level 2, 4KV contact
Level 2, 3V/m
Level 2, 1KV
Level 2, 1KV/Line-Line,Level 3, 2KV/Line-Earth
Level 2, 3Vrms
Level 1, 1A/m
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
Class B
Class B
-----
-----
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Peak current or peak power up to 3 seconds is provided.
3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
4. Tolerance : includes set up tolerance, line regulation and load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. Load regulation is measured from 0% to 100% rated load.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
8. Derating may be needed under low input voltages. Please check the derating curve for more details.
9. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
10. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
File Name:ENP-360-SPEC 2018-05-07
File Name:ENP-360-SPEC 2018-05-07
Block Diagram
360W Level Desktop Type Power Supply
ENP-360 series
Static CharacteristicsDerating Curve
CIRCUIT
DETECTION
EMI FILTER
RECTIFIERS
CIRCUIT
POWER
SWITCHING
FILTER
&
RECTIFIERS
+V
-V
I/P
FG
O.V.P.
&
PFC
CONSTANT
CURRENT
LIMITING &
PWM
O.L.P.
CONTROL
PFC
CONTROL
-30 0 2010 30 40
20
40
80
60
100
6050
70 (HORIZONTAL)
90 100 115 120 140 160 180 190 200 220 240 264
100
90
80
70
60
50
40
INPUT VOLTAGE (V) 60Hz
AMBIENT TEMPERATURE ( )
LOAD (%)
LOAD (%)

ENP-360-12

Mfr. #:
Manufacturer:
Description:
AC/DC CONVERTER 13.8V 359W
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet