Characteristics (T
A
= 25 °C)
Ordering code
V
v
(1 mA)
V
V
v
(1 mA)
%
v
c,max
(i
c
)
V
i
c
A
C
typ
(1 kHz)
pF
Bent strap terminals
B72250L0131K100 205 ±10 340 500 10500
B72250L0151K100 240 ±10 395 500 9500
B72250L0231K100 360 ±10 595 500 6000
B72250L0251K100 390 ±10 650 500 5600
B72250L0271K100 430 ±10 710 500 5500
B72250L0321K100 510 ±10 840 500 4300
B72250L0381K100 620 ±10 1025 500 3500
B72250L0421K100 680 ±10 1120 500 3300
B72250L0441K100 715 ±10 1180 500 3000
B72250L0461K100 750 ±10 1240 500 2900
B72250L0551K100 910 ±10 1500 500 2400
Straight strap terminals
B72250L0131K102 205 ±10 340 500 10500
B72250L0151K102 240 ±10 395 500 9500
B72250L0231K102 360 ±10 595 500 6000
B72250L0251K102 390 ±10 650 500 5600
B72250L0271K102 430 ±10 710 500 5500
B72250L0321K102 510 ±10 840 500 4300
B72250L0381K102 620 ±10 1025 500 3500
B72250L0421K102 680 ±10 1120 500 3300
B72250L0441K102 715 ±10 1180 500 3000
B72250L0461K102 750 ±10 1240 500 2900
B72250L0551K102 910 ±10 1500 500 2400
Strap varistors B722*
HighE, standard, LS50 series
Page 4 of 13Please read Cautions and warnings and
Important notes at the end of this document.
Dimensional drawings
Bent strap terminals
SIOV-LS50K ... P
Weight: 30 ... 90 g
Ordering code
th
max
mm
L ±1.0
mm
Bent strap terminals
B72250L0131K100 8.1 3.5
B72250L0151K100 8.3 3.2
B72250L0231K100 9.0 2.0
B72250L0251K100 9.2 1.8
B72250L0271K100 9.4 1.6
B72250L0321K100 9.9 1.1
B72250L0381K100 10.6 0.4
B72250L0421K100 10.9 0.0
B72250L0441K100 11.1 0.2
B72250L0461K100 11.4 0.4
B72250L0551K100 12.3 1.2
Straight strap terminals
B72250L0131K102 8.1 4.4
B72250L0151K102 8.3 4.6
B72250L0231K102 9.0 5.3
B72250L0251K102 9.2 5.5
B72250L0271K102 9.4 5.8
B72250L0321K102 9.9 6.3
B72250L0381K102 10.6 6.9
B72250L0421K102 10.9 7.3
B72250L0441K102 11.1 7.5
B72250L0461K102 11.4 7.8
B72250L0551K102 12.3 8.7
Straight strap terminals
SIOV-LS50K ... PK2
Weight: 30 ... 90 g
Strap varistors B722*
HighE, standard, LS50 series
Page 5 of 13Please read Cautions and warnings and
Important notes at the end of this document.
Reliability data
Test Test methods/conditions Requirement
Varistor voltage The voltage between two terminals with
the specified measuring current applied
is called V
V
(1 mA
DC
@ 0.2 ... 2 s).
To meet the specified value
Clamping voltage The maximum voltage between two
terminals with the specified standard
impulse current (8/20 µs) applied.
To meet the specified value
Max. DC operating
voltage
The maximum allowable DC operating
voltage V
DC
at UCT +5/–0 °C is applied
for 1000 ±48 h.
The leakage current I
leak
(t) during test is
recorded.
Then the specimen shall be stored at
room temperature and normal humidity
for 1 to 2 h.
Thereafter, the change of V
V
shall be
measured.
I
leak
(t = 1000 h) I
leak
(t = 0 h)
|V/V (1 mA)| 10%
Surge current derating,
8/20 µs
10 surge currents (8/20 µs), unipolar,
interval 60 s, amplitude corresponding
to derating curve for 10 impulses at
20 µs
|V/V (1 mA)| 10%
(measured in direction of
surge current)
No visible damage
Fast temperature cycling IEC 60068-2-14, test Na, LCT/UCT,
dwell time 30 min, 5 cycles
|V/V (1 mA)| 10%
No visible damage
Damp heat, steady state IEC 60068-2-78
The specimen shall be subjected to
40 ±2 °C, 90 to 95% r. H. for 56 ±2 days
with 10% of the maximum continuous
DC operating voltage V
DC
.
Then stored at room temperature and
normal humidity for 1 to 2 h.
Thereafter, the change of V
V
shall be
measured.
|V/V (1 mA)| 10%
Note:
UCT = Upper category temperature
LCT = Lower category temperature
Strap varistors B722*
HighE, standard, LS50 series
Page 6 of 13Please read Cautions and warnings and
Important notes at the end of this document.

B72250L0461K100

Mfr. #:
Manufacturer:
EPCOS / TDK
Description:
Varistors 50mm / 460v
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: